Laserfiche WebLink
Part No: CP041047 <br />SCALE 1/55 WEIGHT: N/A <br /> <br />Installation of 1,000 sq-ft shade structure at the Bristol-Tolliver Street Urban Greening Project (City Project No. 24-6600) <br /> <br /> <br /> <br /> <br /> <br /> <br />Skyways <br />by Landscape Structures Inc. <br />8131 Forney Rd. <br />Dallas TX, 75227 <br />playlsi.com <br />Date: <br />Drawn by: <br />Designed by: <br />Approved by: <br />Drawing: <br />Sheet No.: <br />12/6/24 <br />TM <br />DG <br />A For Approval 12/6/24 <br />TM <br />400-2025-173 SO-01018878 CP041047 <br />DG <br />Hypar Sail <br />SO-01018878 <br />Bristol Tolliver Park <br />712 S Bristol St. <br />Santa Ana, CA, 92703 <br />Project No. <br />Sheet title <br />Sheet Size: <br />Reference Scale: <br />1"1/2"1/2"1/2" <br />#Revision Date By <br />Stamp: <br />Project Info.: <br />'D' 34"x22" <br />1 <br />Revisions <br />General Notes <br />4. EXECUTION: <br />5. CONCRETE: <br />6. STEEL CABLES: <br />i.28 DAY STRENGTH: f'c=4,500 PSI (MIN.) <br />ii.AGGREGATE: HR <br />iii.SLUMP: 3-5 <br />iv.TYPE II/V PORTLAND CEMENT SHALL CONFORM TO ASTM C-150 <br />v.AGGREGATE SHALL CONFORM TO ASTM C-33 <br />vi.NO AIR REQUIRED <br />a.STRUCTURAL WIRE ROPE CABLES SHALL CONFORM TO THE LATEST REVISION OF ASTM A 603, "STANDARD SPECIFICATION <br />FOR ZINC-COATED STEEL STRUCTURAL WIRE ROPE." <br />b.STRUCTURAL STRAND CABLES SHALL CONFORM TO THE LATEST REVISIONS OF A 586, "STANDARD SPECIFICATION FOR <br />ZING-COATED PARALLEL AND HELICAL STEEL WIRE STRUCTURAL STRANDS. <br />c.SEVEN WIRE PRE-STRESSING STRANDS SHALL CONFORM TO THE LATEST REVISION OF ASTM A 416, "STANDARD <br />SPECIFICATION FOR UNCOATED SEVEN WIRE STRESS RELIEVED STRAND FOR PRE-STRESSED CONCRETE" AND SHALL BE <br />GRADE 270. <br />d.WIRE ROPE CABLE SHALL BE 7X19 STRAND CORE GALVANIZED WIRE ROPE WITH A BREAKING STRENGTH VALUE OF: <br />i. 3/8" DIAMETER= 14,000 LBS <br />e.CABLES SHALL BE FED THROUGH THE FABRIC SLEEVES AROUND THE PERIMETER OF THE CANOPY AND TENSIONED UNTIL <br />THE FABRIC PANELS (DESIGNED PURPOSELY UNDERSIZED) REACH A TAUGHT APPEARANCE. ANY LONG-TERM CABLE SAG <br />SHALL BE MINIMIZED DURING THE MAINTENANCE RE-TIGHTENING VISITS AS REQUIRED. <br />a.CONCRETE WORK SHALL BE EXECUTED IN ACCORDANCE WITH THE LATEST EDITION OF THE AMERICAN CONCRETE INSTITUTE <br />BUILDING CODE. <br />b.CONCRETE SPECIFICATIONS SHALL BE AS FOLLOWS: <br /> <br /> <br /> <br /> <br /> <br /> <br />c.ALL CONCRETE STEEL REINFORCEMENT SHALL CONFORM TO ASTM A-615 GRADE 60. <br />d.REINFORCING STEEL SHALL BE DETAILED, FABRICATED, AND PLACED IN ACCORDANCE WITH THE LATEST ACI DETAILING <br />MANUAL AND RSI MANUAL OF STANDARD PRACTICE. <br />e.REINFORCING CONCRETE COVER SHALL BE 3" MIN. <br />f.ALL CAST-IN-PLACE CONCRETE SHALL BE COMPACTED USING HIGH FREQUENCY VIBRATING EQUIPMENT. <br />g.TOP OF PIERS ARE DESIGNED NON-CONSTRAINED. <br />h.ALL ANCHOR BOLTS SET IN CONCRETE SHALL COMPLY WITH ASTM F-1554 GRADE 55 <br />i.ALL NON-SHRINK GROUT SHALL HAVE A MINIMUM 28 DAYS COMPRESSIVE STRENGTH OF 5000 PSI AND SHALL COMPLY <br />WITH THE REQUIREMENTS OF ASTM C-109, ASTM C939, ASTM C1090 WHEN APPLICABLE. <br />j.PRIOR TO INSTALLATION OF FOUNDATION, INSTALLER SHALL VERIFY SOILS APPEAR TO BE CAPABLE BEARING SOILS AND ARE <br />NOT MUDDY, LIQUIDY, OR ANY OTHER FORM OF NON-LOAD BEARING SOIL. <br />a.STEEL FABRICATOR SHALL PROVIDE EFFECTIVE, FULL TIME QUALITY CONTROL OVER ALL FABRICATION ACTIVITIES. <br />b.VISUAL INSPECTION SHALL BE PERFORMED TO ENSURE ALL WELDS CONFORM TO AWS STANDARDS. <br />c.GRIND SMOOTH ALL SHARP EDGES AND CORNERS <br />a.ALL WELDS SHALL BE CONTINUOUS WHERE LENGTH IS NOT GIVEN. <br />b.ALL WELDS SHALL DEVELOP THE FULL STRENGTH OF THE WEAKER MEMBER. ALL WELDS SHALL BE MADE USING E70XX <br />.035 OR .045 WIRE. <br />c.ALL WELDED JOINTS SHALL CONFORM TO AWS PRE-QUALIFIED WELDED JOINTS AS DESIGNATED BY THE STANDARD <br />WELD SYMBOLS AND TERMS AS SHOWN ON THE DRAWINGS. <br />d.WELDS SHALL BE MADE ONLY BY OPERATORS WHO HAVE BEEN PREVIOUSLY QUALIFIED BY TESTS, AS PRESCRIBED IN <br />THE LATEST EDITION OF THE AMERICAN WELDING SOCIETY, D1.1, "STRUCTURAL WELDING CODE", TO PERFORM THE <br />TYPE OF WORK REQUIRED. <br />e.SHOP CONNECTIONS SHALL BE WELDED U.N.O. FIELD CONNECTIONS SHALL BE BOLTED AS INDICATED ON THE <br />DRAWINGS. WELDING OF FIELD CONNECTIONS SHALL NOT BE ACCEPTED WITHOUT WRITTEN CONSENT FROM THE <br />EOR. <br />f.ALL FILLET WELDS SHALL BE A MINIMUM OF 3/16" UNLESS OTHERWISE NOTED. <br />g.ALL HIGH STRENGTH BOLTS SHALL COMPLY WITH A325 OR EQUIVALENT. <br />h.ALL HIGH STRENGTH NUTS SHALL COMPLY WITH A563C OR EQUIVALENT. <br />i.ALL HIGH STRENGTH WASHERS SHALL COMPLY WITH F436-1 OR EQUIVALENT. <br />j.ALL STAINLESS STEEL BOLTS SHALL COMPLY WITH ASTM F-593, ALLOY GROUP 1 OR 2 OR EQUIVALENT. <br />k.ALL STAINLESS STEEL NUTS SHALL COMPLY WITH ASTM F-594 ALLOY GROUP 1 OR 2 OR EQUIVALENT. <br />l.ALL STAINLESS STEEL WASHERS SHALL CONFORM TO TYPE 18-8 OR EQUIVALENT. <br />m.ALL LOCK WASHERS SHALL BE SPLIT-RING <br />n.COMMON SPRING LOCK WASHERS SHALL CONFORM TO ANSI B.18.21.1 <br />BOLTS SHALL BE TIGHETENED TO A SNUG CONDITION <br />o.TOLERANCES ON HOLES FOR CONNECTIONG PLATES AND BOLTED ELEMENTS IN FIELD SHALL BE +1/16" LARGER THAN <br />THE NOMINAL DIAMETER OF THE BOLT, FOR BASE PLATES IT SHALL BE 1/8" LARGER. BOLT HOLES IN METAL PARTS <br />MAY BE BURNED USING A FLAME CUTTING MACHINE. <br />p.SPECIAL ATTENTION SHALL BE GIVEN TO WELDS IN AREAS IN DIRECT CONTACT WITH SHADE FABRIC TO ENSURE THAT <br />THESE WELDS ARE GROUND SMOOTH AND DO NOT HAVE SHARP EDGES OR BURRS. <br />q.ALL THREADED ROD SHALL CONFORM TO ASTM A36, OR ASTM A 572, GRADE 50. <br />3. BOLTS AND WELDS: SHALL CONFORM TO THE FOLLOWING REQUIREMENTS U.N.O <br />a.PIPES SHALL CONFORM TO ASTM A 53, GRADE B, TYPE E OR S. <br />b.STRUCTURAL TUBING SHALL CONFORM TO ASTM A 500, GRADE B/C. <br />c.PLATES AND BARS SHALL CONFORM TO ASTM A 36 OR A 572 GRADE 50. <br />d.TUBING SHALL BE INTERNALLY COATED WITH ZINC AND ORGANIC COATINGS TO PREVENT CORROSION AS <br />MANUFACTURED BY ALLIED TUBE & CONDUIT. <br />e.PINS SHALL CONFORM TO ASTM A 36, OR ASTM A 588, GRADE 50. ALL PINS SHALL BE GALVANIZED. <br />f.ALL STRUCTURAL STEEL SHALL BE SHOT BLASTED PRIOR TO PAINT <br />g.ALL WORK SHALL BE FREE OF OIL, GREASE, AND MACHINING CHIPS. <br />2. MATERIALS: MEMBERS SHALL CONFORM TO THE FOLLOWING REQUIREMENTS U.N.O. <br />i.AMERICAN INSTITUTE OF STEEL CONSTRUCTION - "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND <br />BRIDGES." <br />ii.AMERICAN INSTITUTE OF STEEL CONSTRUCTION - "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS." <br />iii.AMERICAN INSTITUTE OF STEEL CONSTRUCTION - "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A 325 <br />OR A 490 BOLTS." <br />iv.AMERICAN WELDING SOCIETY - "STRUCTURAL WELDING CODE" AWS D1.1 <br />v.AMERICAN SOCIETY FOR TESTING AND MATERIALS - AS REFERENCED HEREIN. <br />vi.AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) - AS REFERENCED. <br />1. GENERAL NOTES: <br /> a. ALL WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FOLLOWING: <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> b. DO NOT SCALE OFF OF DRAWINGS <br />GENERAL NOTES: <br />DESIGN INFORMATION <br />CODE AND LOADS: <br />BUILDING CODE: CBC 2022 <br />OCCUPANCY CLASSIFICATION - A-3 <br />CONSTRUCTION TYPE -VB <br />RISK CATEGORY - II <br />SINGLE STORY STRUCTURE <br /> <br />LOADS: <br />DEAD LOAD= SELF WEIGHT <br />LIVE LOAD = 5 PSF <br /> <br />DESIGN WIND LOAD Vult=105 MPH, 0.85 SEC. GUST <br /> <br />EXPOSURE: C <br />KZT: 1 <br /> <br />GROUND SNOW LOADS: 5 PSF <br /> <br />THIS STRUCTURE WAS NOT DESIGNED FOR A FLOOD HAZARD AREA. <br /> <br />SOILS WERE EVALUATED USING VALUES OBTAINED FROM GEOTECHNICAL REPORT PROJECT NO:24-6600 BY TERRACON, DATED NOVEMBER 14, 2024. PRIOR TO PLACEMENT OF ANY FOUNDATION ELEMENTS, CONTRACTOR <br />SHALL EXAMINE THE SOIL AND VERIFY THE BEARING STRATA (BOTTOM OF FOOTING) DOES NOT CONTAIN MUD, ORGANIC SILT, ORGANIC CLAYS, PEAT, UNPREPARED FILL, OR ANY FORM OF NON-LOAD BEARING CAPABLE <br />SOILS. IF ANY OF THESE CONDITIONS ARE ENCOUNTERED, CONTRACTOR SHALL NOTIFY SKYWAYS IMMEDIATELY FOR ADDITIONAL RECOMMENDATIONS. CONTRACTOR SHALL REVIEW GEOTECHNICAL REPORT FOR <br />ADDITIONAL REQUIREMENTS INVOLVING SOIL PREPARATION, CASING, ETC. PRIOR TO BEGINNING DRILLING OPERATIONS. REFERENCE GEOTECHNICAL REPORT FOR ANY ADDITIONAL REQUIREMENTS. <br /> <br />ALLOWABLE BEARING 1750 PSF <br /> <br />LATERAL BEARING: 175 PSF/FT - PER 1806.3.4, IN DETERMINING OUR S1 VALUES IN THE CALCS, WE HAVE DOUBLED THIS VALUE. <br />WE REACHED OUT TO THE GEOTECHNICAL ENGINEER PRIOR TO DOING THIS FOR THEIR APPROVAL AND WERE GIVEN PERMISSION TO DO THIS. <br /> <br />CABLE STRESS: 800 LBS MIN <br />7. FABRIC NOTES: <br />a.FABRIC SHALL BE MANUFACTURED BY GALE PACIFIC OR ANY OTHER MANUFACTURER WHO CAN MEET THE <br />SPECIFICATIONS LISTED BELOW. <br />b.FABRIC SHALL BE POLYETHYLENE MATERIAL <br />c.THE FABRIC SHALL ACHIEVE AN ULTIMATE TENSILE CAPACITY WHEN TESTED PER ASTM D-5034 IN THE: <br />d.WARP DIRECTION OF 100 LBS PER INCH AT 66% MAX ELONGATION. <br />e.FILL DIRECTION OF 50 LBS PER INCH AT 33% MAX ELONGATION. <br />f.ACROSS THE SEAM OF STITCHING OF 80 LBS PER INCH AT 80% MAX ELONGATION <br />g.THE FABRIC SHALL RETAIN 80% OF ITS TENSILE AND TEARING STRENGTH AFTER ULTRAVIOLET EXPOSURE PER ASTM G53 <br />USING A 313 NM LIGHT SOURCE FOR 500 HOURS WHILE MOISTENED FOR 1 HOUR EVERY 12 HOURS. <br />h.FABRIC SHALL REQUIRE ANNUAL INSPECTION AND MAINTENANCE. FABRIC SAMPLES OF THE SAME MATERIAL WHICH <br />ARE MAINTAINED AT THE PROJECT SITE SHALL BE TESTED TO BE IN COMPLIANCE WITH ASTM D5034 AND D2261. THE <br />ANNUAL TESTING ON THE APPROVED PLANS SHALL BE COMPARED TO THE FABRIC SPECIFICATIONS INDICATED ABOVE. <br />THE FABRIC SHALL BE REPLACED WHEN THE TEST RESULTS RETURN LESS THAN 50% OF THE ULTIMATE VALUES NOTED <br />ABOVE. <br />i.IT IS REQUIRED THAT THE FABRIC TOP SHALL BE REMOVED PRIOR TO A NATURAL EVENT WHERE THE SNOW AND <br />WIND LOADS EXCEED S WHAT IS SPECIFIED UNDER "DESIGN INFORMATION". <br />j.A VISUAL INSPECTION LOOKING FOR TEAR AND ABNORMAL WEAR IN FABRIC MATERIAL AND THREAD IS REQUIRED <br />PRIOR TO RE-INSTALLATION. SHADE STRUCTURE MANUFACTURER SHALL BE NOTIFIED IF SIGNIFICANT DAMAGE IS <br />PRESENT BEFORE RE-INSTALLATION. <br />k.FABRIC MEMBRANES SHALL CONFORM TO FIRE PROPAGATION PERFORMANCE CRITERIA OF NFPA 701, OR HAVE A <br />FLAME SPREAD INDEX NOT GREATER THAN 25 WHEN TESTED IN ACCORDANCE WITH ASTM E 84. <br /> <br />AMMTEC CONSULTANTS FOR <br />Oct 22, 2025