2130, 2150 & 2160 E Fourth St - Electrical Revision - Plan
PBA
>
Building
>
ProjectDox
>
F
>
Fourth St
>
2130 E Fourth St
>
2130, 2150 & 2160 E Fourth St - Electrical Revision - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/15/2026 5:00:13 AM
Creation date
1/15/2026 5:00:04 AM
Metadata
Fields
Template:
Plan
Permit Number
20187473
20187474
20187475
Full Address
2130 E Fourth St
2150 E Fourth St
2160 E Fourth St
Street Number
2160
Street Direction
E
Street Name
Fourth
Street Suffix
St
Text box
ID:
1
Creator:
Import Agent
Created:
1/15/2026 5:00 AM
Modified:
1/13/2026 4:39 PM
Text:
Elec#: 20187473-75 REV TO: Elec#: 20184368-9, 71 APPROVALS: Elec: MSmith
Stamp
ID:
1
Creator:
Import Agent
Created:
1/15/2026 5:00 AM
Modified:
1/13/2026 4:39 PM
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
PC COMMENTS RESPONSE #1 01/29/2025A <br />al <br />l <br /> <br />i <br />d <br />e <br />a <br />s <br />, <br /> <br />d <br />e <br />s <br />i <br />g <br />n <br />s <br /> <br />a <br />n <br />d <br /> <br />p <br />l <br />a <br />n <br />s <br /> <br />r <br />e <br />p <br />r <br />e <br />s <br />e <br />n <br />t <br />e <br />d <br /> <br />b <br />y <br /> <br />t <br />h <br />i <br />s <br /> <br />d <br />r <br />a <br />w <br />i <br />n <br />g <br /> <br />a <br />r <br />e <br /> <br />t <br />h <br />e <br /> <br />e <br />x <br />c <br />l <br />u <br />s <br />i <br />v <br />e <br /> <br />p <br />r <br />o <br />p <br />e <br />r <br />t <br />y <br /> <br />o <br />f <br />Go <br />u <br />v <br />i <br />s <br /> <br />E <br />n <br />g <br />i <br />n <br />e <br />e <br />r <br />i <br />n <br />g <br /> <br />a <br />n <br />d <br /> <br />s <br />h <br />a <br />l <br />l <br /> <br />n <br />o <br />t <br /> <br />b <br />e <br /> <br />r <br />e <br />p <br />r <br />o <br />d <br />u <br />c <br />e <br />d <br /> <br />i <br />n <br /> <br />w <br />h <br />o <br />l <br />e <br /> <br />o <br />r <br /> <br />i <br />n <br /> <br />p <br />a <br />r <br />t <br /> <br />w <br />i <br />t <br />h <br />o <br />u <br />t <br /> <br />t <br />h <br />e <br /> <br />e <br />x <br />p <br />r <br />e <br />s <br />s <br /> <br />p <br />r <br />i <br />o <br />r <br /> <br />w <br />r <br />i <br />t <br />t <br />e <br />n <br /> <br />p <br />e <br />r <br />m <br />i <br />s <br />s <br />i <br />o <br />n <br /> <br />o <br />f <br /> <br />s <br />a <br />i <br />d <br /> <br />e <br />n <br />g <br />i <br />n <br />e <br />e <br />r <br />s <br />, <br /> <br />a <br />n <br />y <br /> <br />u <br />n <br />a <br />u <br />t <br />h <br />o <br />r <br />i <br />z <br />e <br />d <br /> <br />r <br />e <br />u <br />s <br />e <br /> <br />o <br />f <br /> <br />t <br />h <br />e <br />s <br />e <br /> <br />p <br />l <br />a <br />n <br />s <br /> <br />o <br />t <br />h <br />e <br />r <br /> <br />t <br />h <br />a <br />n <br /> <br />f <br />o <br />r <br /> <br />t <br />h <br />e <br /> <br />p <br />r <br />o <br />j <br />e <br />c <br />t <br /> <br />a <br />n <br />d <br /> <br />l <br />o <br />c <br />a <br />t <br />i <br />o <br />n <br /> <br />s <br />h <br />o <br />w <br />n <br /> <br />i <br />s <br /> <br />p <br />r <br />o <br />h <br />i <br />b <br />i <br />t <br />e <br />d <br />. <br />JOB NO. <br />SUBMITTAL <br />DATE <br />SHEET TITLE <br />SHEET NO. <br />CLIENT: <br />REVISION <br />DATE <br />21 <br />3 <br />0 <br /> <br />E <br /> <br />4 <br />T <br />H <br /> <br />S <br />T <br /> <br /># <br />2 <br />0 <br />0 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />BSB: MR230056; Gouvis: 66467 <br />WATER REVISIONS <br />09/12/2025 <br />1ST PLAN CHECK SUBMITTAL 08/20/2024 <br />2ND PLAN CHECK SUBMITTAL 1/29/2025 <br />PC COMMENTS RESPONSE #2 04/17/2025B <br />3RD PLAN CHECK SUBMITTAL 04/17/2025 <br />PC COMMENTS RESPONSE #3 07/10/2025C <br />4TH PLAN CHECK SUBMITTAL 07/10/2025 <br />WATER REVISIONS 09/12/2025D <br />WATER REVISIONS 09/12/2025 <br />PC COMMENTS RESPONSE #4 10/10/2025E <br />CLIENT REVISIONS 10/10/20251 <br />OL <br />I <br />V <br />E <br /> <br />C <br />R <br />E <br />S <br />T <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />T <br />I <br />A <br />L <br />21 <br />5 <br />0 <br /> <br />E <br />. <br /> <br />F <br />O <br />U <br />R <br />T <br />H <br /> <br />A <br />N <br />D <br /> <br />2 <br />1 <br />6 <br />0 <br /> <br />E <br />. <br /> <br />F <br />O <br />U <br />R <br />T <br />H <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />5 <br />OL <br />I <br />V <br />E <br /> <br />C <br />R <br />E <br />S <br />T <br />DATE SIGNED: 7/8/25 <br />SHEET INDEX & GENERAL NOTES <br />ELECTRICAL SHEET INDEX <br />NO.SHEET DESCRIPTION <br />1 E-0.0 SHEET INDEX & GENERAL NOTES <br />2 E-0.1A SPECIFICATIONS NOTES <br />3 E-0.1B GENERAL NOTES <br />4 E-0.1C MANDATORY MEASURES NOTES <br />5 E-0.2 ABBREVIATIONS & SYMBOL LIST <br />6 E-0.3A DETAILS <br />7 E-0.3B DETAILS <br />8 E-0.3C DETAILS <br />9 E-0.3D DETAILS <br />10 E-0.4 SINGLE LINE DIAGRAM & EQUIPMENT ELEVATION <br />11 E-0.5 LOAD CALCULATIONS & EQUIPMENT SCHEDULES <br />12 E-0.6 PANEL SCHEDULES <br />13 E-1.1 SITE UTILITY PLAN <br />14 E-1.2 SITE LIGHTING PLAN <br />15 E-1.3 PHOTOMETRIC SITE PLAN <br />16 E-1.4 LIGHTING SPECIFICATIONS <br />17 E-2.1 BUILDING A1 - LEVEL 1 FLOOR - POWER PLAN <br />18 E-2.2 BUILDING A1 - LEVEL 2 FLOOR - POWER PLAN <br />19 E-2.3 BUILDING A1 - ROOF PLAN <br />20 E-2.4 BUILDING A2 - LEVEL 1 FLOOR - POWER PLAN <br />21 E-2.5 BUILDING A2 - LEVEL 2 FLOOR - POWER PLAN <br />22 E-2.6 BUILDING A2 - ROOF PLAN <br />23 E-2.7 BUILDING A1 - LEVEL 1 FLOOR - LIGHTING PLAN <br />24 E-2.8 BUILDING A1 - LEVEL 2 FLOOR - LIGHTING PLAN <br />25 E-2.9 BUILDING A2 - LEVEL 1 FLOOR - LIGHTING PLAN <br />26 E-2.10 BUILDING A2 - LEVEL 2 FLOOR - LIGHTING PLAN <br />27 E-3.1 UNIT PLANS <br />28 E-4.1 NORMAL PHOTOMETRIC - LEVEL 1 <br />29 E-4.2 NORMAL PHOTOMETRIC - LEVEL 2 <br />30 E-4.3 EGRESS PHOTOMETRIC - LEVEL 1 <br />31 E-4.4 EGRESS PHOTOMETRIC - LEVEL 2 <br />32 E-4.5 LIGHTING SPECIFICATIONS <br />33 E-5.1 TITLE 24 LTO OUTDOOR FORMS <br />34 E-5.2 TITLE 24 LTI INDOOR FORMS - UNIT A-1 - LAUNDRY <br />PARTIAL <br />2022 CAL GREEN EV CAPABLE NOTES <br />THE 2022 CALGREEN CODES BECOME EFFECTIVE ON JANUARY 1, 2023, PER SECTION 5.106.5.3. <br />1.ALL RESIDENTIAL CONSTRUCTION INCLUDES SINGLE-FAMILY, TOWNHOMES, & DUPLEXES MUST BE EV <br />CAPABLE. <br />2.EACH DWELLING UNIT MUST HAVE A LISTED RACEWAY TO ACCOMMODATE A DEDICATED <br />208/240-VOLT BRANCH CIRCUIT. <br />3.IN MULTI-FAMILY DWELLINGS THE "EV CAPABLE" IS BASED ON THE PERCENT OF TOTAL PARKING <br />SPACES. <br />4.IN HOTEL AND NONRESIDENTIAL CONSTRUCTION, "EV CAPABLE" SPACES ARE REQUIRED BASE ON <br />THE TOTAL NUMBER OF PARKING SPACES AT ALL TYPES OF PARKING FACILITIES (E.G., GARAGES, <br />FLAT LOTS, VALET). <br />5.THE RACEWAY SHALL NOT BE LESS THAN 1 INCH, SHALL ORIGINATE AT THE MAIN SERVICE OR <br />SUBPANEL, AND SHALL TERMINATE INTO A LISTED CABINET BOX, OR OTHER ENCLOSURE IN CLOSE <br />PROXIMITY TO THE PROPOSED LOCATION OF AN EV CHARGER. <br />6.THE PANEL OR SUBPANEL SHALL PROVIDE CAPACITY TO INSTALL A 40-AMPERE MINIMUM DEDICATED <br />BRANCH CIRCUIT AND SPACE(S) RESERVED TO PERMIT INSTALLATION OF A BRANCH CIRCUIT <br />OVERCURRENT PROTECTIVE DEVICE. <br />7.THE SERVICE PANEL OR SUBPANEL CIRCUIT DIRECTORY SHALL IDENTIFY THE OVERCURRENT <br />PROTECTIVE DEVICE SPACE(S) RESERVED FOR EVE CHARGING AS "EV CAPABLE." <br />8.THE RACEWAY TERMINATION LOCATION SHALL BE PERMANENTLY AND VISIBLY MARKED AS "EV <br />CAPABLE." <br />2022 ENERGY CODE NOTE <br />ENERGY STORAGE SYSTEM (ESS) READY <br />PER SECTION 150.0(S) TITLE 24 PART 6, ALL SINGLE-FAMILY RESIDENCES, THAT INCLUDE ONE OR TWO <br />DWELLING UNITS SHALL MEET THE FOLLOWING: <br />1. WILL NEED EITHER INTERCONNECTION EQUIPMENT WITH CAPACITY OF AT LEAST 60 AMPS OR <br />DEDICATED RACEWAY FOR THE BRANCH CIRCUITS. <br />2. AT LEAST 4 BRANCH CIRCUITS TO FEED ITEMS IN THE HOME (REFRIGERATOR, ONE LIGHTING <br />CIRCUIT SHALL BE LOCATED NEAR THE PRIMARY EGRESS, AND AT LEAST ONE CIRCUIT SHALL <br />SUPPLY A SLEEPING ROOM RECEPTACLE OUTLET). <br />3. THE MAIN PANEL BOARD SHALL HAVE A MINIMUM BUS BAR RATING OF 225 AMPS. <br />4. RESERVE SPACE AND RACEWAY FOR FUTURE ISOLATION EQUIPMENT OR TRANSFER SWITCH <br />WITHIN 3' OF MAIN PANEL. <br />HEAT PUMP SPACE HEATER READY <br />PER SECTION 150.0(T) TITLE 24, PART 6, SUBCHAPTER 7, IF NATURAL OR PROPANE GAS FURNACES ARE <br />INSTALLED: <br />1.DEDICATED, 240-VOLT BRANCH CIRCUIT WIRING MUST BE INSTALLED WITHIN 3 FT FROM THE <br />FURNACE AND ACCESSIBLE TO THE FURNACE WITH NO OBSTRUCTIONS. THE BRANCH CIRCUIT <br />CONDUCTORS MUST BE RATED AT 30 AMPS MINIMUM. THE BLANK COVER MUST BE LABELED "240V <br />READY." ALL ELECTRICAL COMPONENTS MUST BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA <br />ELECTRICAL CODE; AND <br />2.THE MAIN ELECTRICAL SERVICE PANEL MUST HAVE A RESERVED SPACE TO ALLOW FOR THE <br />INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER PERMANENTLY LABELED "FOR FUTURE 240V <br />USE" <br />ELECTRIC COOKTOP READY <br />PER 150.0(U) TITLE 24, PART 6, SUBCHAPTER 7, SYSTEMS USING A GAS OR PROPANE COOKTOP TO SERVE <br />INDIVIDUAL DWELLING UNITS MUST INCLUDE THE FOLLOWING: <br />1.DEDICATED, 240-VOLT BRANCH CIRCUIT WIRING MUST BE INSTALLED WITHIN 3 FT FROM THE <br />COOKTOP AND ACCESSIBLE TO THE COOKTOP WITH NO OBSTRUCTIONS. THE BRANCH CIRCUIT <br />CONDUCTORS MUST BE RATED AT 50 AMPS MINIMUM. THE BLANK COVER MUST BE LABELED "240V <br />READY." ALL ELECTRICAL COMPONENTS MUST BE INSTALLED IN ACCORDANCE WITH THE CALIFORNIA <br />ELECTRICAL CODE; AND <br />2.THE MAIN ELECTRICAL SERVICE PANEL MUST HAVE A RESERVED SPACE TO ALLOW FOR THE <br />INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE ELECTRIC COOKTOP <br />INSTALLATION. THE RESERVED SPACE MUST BE PERMANENTLY LABELED "FOR FUTURE 240V USE." <br />ELECTRIC CLOTHES DRYER READY <br />PER 150.0(V) TITLE 24, PART 6, SUBCHAPTER 7, CLOTHES DRYER LOCATIONS WITH GAS OR PROPANE <br />PLUMBING TO SERVE INDIVIDUAL DWELLING UNITS MUST INCLUDE THE FOLLOWING: <br />1.DEDICATED, 240-VOLT BRANCH CIRCUIT WIRING MUST BE INSTALLED WITHIN 3 FT FROM THE <br />CLOTHES DRYER LOCATION AND ACCESSIBLE TO THE CLOTHES DRYER LOCATION WITH NO <br />OBSTRUCTIONS. THE BRANCH CIRCUIT CONDUCTORS MUST BE RATED AT 30 AMPS MINIMUM. THE <br />BLANK COVER MUST BE LABELED "240V READY." ALL ELECTRICAL COMPONENTS MUST BE INSTALLED <br />IN ACCORDANCE WITH THE CALIFORNIA ELECTRICAL CODE; AND. <br />2.THE MAIN ELECTRICAL SERVICE PANEL MUST HAVE A RESERVED SPACE TO ALLOW FOR THE <br />INSTALLATION OF A DOUBLE POLE CIRCUIT BREAKER FOR A FUTURE ELECTRIC CLOTHES DRYER <br />INSTALLATION. THE RESERVED SPACE MUST BE PERMANENTLY LABELED "FOR FUTURE 240V USE." <br />GFCI NOTES FOR DWELLING UNITS <br />PER 210.8(A) ALL 125-VOLT THROUGH 250-VOLT RECEPTACLES INSTALLED IN THE LOCATIONS BELOW <br />THAT SPECIFIED IN 210.8(A)(1) THROUGH (A)(11) AND SUPPLIED BY SINGLE-PHASE BRANCH CIRCUITS <br />RATED 150 VOLTS OR LESS TO GROUND SHALL HAVE GROUND-FAULT CIRCUIT-INTERRUPTER <br />PROTECTION FOR PERSONNEL. <br />(1)BATHROOMS <br />(2)GARAGES <br />(3)OUTDOORS <br />(4)CRAWL SPACES OR BELOW GRADE LEVEL <br />(5)BASEMENTS <br />(6)KITCHENS — WHERE THE RECEPTACLES ARE INSTALLED TO SERVE THE COUNTERTOP SURFACES <br />(7)SINKS — WHERE RECEPTACLES ARE INSTALLED WITHIN 1.8 M (6 FT) FROM THE TOP INSIDE EDGE OF <br />THE BOWL OF THE SINK <br />(8)BOATHOUSES <br />(9)BATHTUBS OR SHOWER STALLS — WHERE RECEPTACLES ARE INSTALLED WITHIN 1.8 M (6 FT) OF <br />THE OUTSIDE EDGE OF THE BATHTUB OR SHOWER STALL <br />(10)LAUNDRY AREAS <br />(11)INDOOR DAMP AND WET LOCATIONS. <br />AFCI NOTES FOR DWELLING UNITS <br />PER 210.12(A) ALL 120-VOLT, SINGLE-PHASE, 15- AND 20-AMPERE BRANCH CIRCUITS SUPPLYING OUTLETS <br />OR DEVICES INSTALLED IN DWELLING UNIT KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, <br />PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, <br />LAUNDRY AREAS, OR SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY ANY OF THE MEANS <br />DESCRIBED IN 210.12(A)(1) THROUGH (6). <br />NOTE: <br />A COMPLETED ELECTRICAL PERMIT SHALL BE PROVIDED FOR EACH PHASE/TYPE OF CONSTRUCTION. <br />E-0.0 <br />SHEET INDEX & <br />GENERAL NOTES