My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1425 W River Ln - Plan
PBA
>
Building
>
ProjectDox
>
R
>
River Ln
>
1425 W River Ln
>
1425 W River Ln - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/13/2026 5:03:18 AM
Creation date
2/13/2026 5:01:13 AM
Metadata
Fields
Template:
Plan
Permit Number
20186400
101124334
Full Address
1425 W River Ln
Street Number
1425
Street Direction
W
Street Name
River
Street Suffix
Ln
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
COVER SHEET <br />PHOTOVOLTAIC ROOF MOUNT SYSTEM <br />SHEET NAME <br />SHEET NUMBER <br />PV-0 <br />PROJECT NAME <br />SHEET SIZE <br />ANSI B <br />11" X 17" <br />V1.0.0 <br />REVDATEDESCRIPTION <br />VERSION <br />URINITIAL RELEASE <br />EMPOWER ELECTRIC SOLAR <br />683 N POLLASKY AVE <br />CLOVIS, CA 93611 <br />TEL: (800) 306 6953 <br />CSLB: 1057693 <br />Email : permits@mpwrsolar.com <br />05/22/2025 <br />KE <br />N <br />N <br />E <br />T <br />H <br /> <br />C <br />H <br />E <br />A <br />T <br />H <br />A <br />M <br />14 <br />2 <br />5 <br /> <br />W <br /> <br />R <br />I <br />V <br />E <br />R <br /> <br />L <br />N <br />, <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />, <br /> <br />U <br />S <br />A <br />UT <br />I <br />L <br />I <br />T <br />Y <br />: <br /> <br />S <br />O <br />U <br />T <br />H <br />E <br />R <br />N <br /> <br />C <br />A <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br /> <br />E <br />D <br />I <br />S <br />O <br />N <br />(S <br />C <br />E <br />) <br />AP <br />N <br />: <br /> <br />0 <br />0 <br />1 <br />- <br />2 <br />9 <br />2 <br />- <br />2 <br />0 <br />A08-07-2025REVISION <br />SHEET INDEX <br />PV-0 COVER SHEET <br />PV-1 SITE PLAN WITH ROOF PLAN <br />PV-2 ROOF PLAN WITH MODULES <br />PV-3 ATTACHMENT DETAIL <br />PV-3.1 BATTERY MOUNTING DETAILS <br />PV-4 ELECTRICAL LINE DIAGRAM WITH <br />WIRE CALCULATIONS <br />PV-5 WARNING LABELS & PLACARD <br />PV-5.1 EXISTING PLACARD <br />PV-6+EQUIPMENT SPEC SHEETS <br />2 VICINITY MAP <br />SCALE: NTSPV-0 <br />1 AERIAL PHOTO <br />SCALE: NTSPV-0 <br />GENERAL NOTES <br />·THE CONTRACTOR/INSTALLER OF THE SOLAR PV SYSTEM OVER EXISTING <br />ROOF SHALL CONFORM TO OSHA REQUIREMENTS DURING THE <br />CONSTRUCTION PHASE. JOB SAFETY AND CONSTRUCTION PROCEDURES <br />ARE THE SOLE RESPONSIBILITY OF THE CONTRACTOR/INSTALLER. <br />·REFER TO ELECTRICAL DRAWING PV-4 FOR PANEL DETAILED INFORMATION. <br />·IN CASE OF CONFLICT BETWEEN STRUCTURAL DRAWINGS AND ELECTRICAL <br />DRAWINGS, THE MOST RIGID REQUIREMENTS SHALL GOVERN. <br />·THE CONTRACTOR/INSTALLER SHALL VERIFY ALL EXISTING BUILDING <br />INFORMATION SHOWN (DIMENSIONS, ROOF TOP PROJECTIONS, ETC.) AND <br />NOTIFY THE ENGINEER OF ANY DISCREPANCIES PRIOR TO INSTALLATIONS <br />OF PV SYSTEM. <br />·THE CONTRACTOR/INSTALLER SHALL VERIFY AND COORDINATE EXISTING <br />OPENINGS, ROOF TOP UNITS, VENT PIPES, ETC. SHOWN ON DRAWINGS. IF <br />THERE IS A DISCREPANCY BETWEEN DRAWINGS, IT IS THE <br />CONTRACTORS/INSTALLER'S RESPONSIBILITY TO NOTIFY ENGINEER PRIOR <br />TO PERFORMING THE WORK. <br />·ALL CONSTRUCTION IS TO BE PERFORMED IN STRICT CONFORMANCE WITH <br />ALL APPLICABLE TOWN, COUNTY & STATE REGULATIONS AND/OR ANY <br />OTHER GOVERNING BODIES. <br />· DO NOT SCALE THESE DRAWINGS, USE DIMENSIONS. CONTRACTOR MUST <br />CONDUCT ROOF SURVEY TO VERIFY DIMENSIONS SHOWN ON PLAN PRIOR <br />TO INSTALLATION. IF THERE IS A DISCREPANCY IT IS <br />CONTRACTOR/INSTALLER'S RESPONSIBILITY TO NOTIFY THE ENGINEER <br />IMMEDIATELY. <br />·LOCATED IN AREAS NOT REQUIRING PLACEMENT OF GROUND LADDERS <br />OVER OPENINGS SUCH AS DOORS OR WINDOWS. <br />·LOCATED AT STRONG POINTS OF BUILDING CONSTRUCTION IN LOCATIONS <br />WHERE ACCESS POINT DOES NOT CONFLICT WITH OVERHEAD <br />OBSTRUCTIONS SUCH AS TREE LIMBS, WIRES, OR SIGNS. <br />·DISCONNECT MEANS MUST HAVE DEDICATED CLEAR UNOBSTRUCTED <br />WORKING SPACE NOT LESS THAN 3' DEEP BY 2.5' WIDE TO NOT LESS THAN <br />6.5' ABOVE WALKABLE SURFACES IN FRONT OF DISTRIBUTION PANEL. <br />·ALL SOLAR MODULES, EQUIPMENT, AND METALLIC COMPONENTS TO BE <br />BONDED. <br />·PV ARRAY NOT TO EXCEED HIGHEST POINT OF THE ROOF. <br />·RAPID SHUTDOWN IS ACTIVATED AT THE INVERTER BY THE AC <br />DISCONNECT. <br />ELECTRICAL NOTES <br />·ALL EQUIPMENT TO BE LISTED BY UL OR OTHER NRTL, AND LABELED FOR <br />ITS APPLICATION. <br />·ALL CONDUCTORS SHALL BE COPPER, RATED FOR 600 V AND 90 DEGREE C <br />WET ENVIRONMENT. <br />·WIRING, CONDUIT, AND RACEWAYS MOUNTED ON ROOFTOPS SHALL BE <br />ROUTED DIRECTLY TO, AND LOCATED AS CLOSE AS POSSIBLE TO THE <br />NEAREST RIDGE, HIP, OR VALLEY. <br />·WORKING CLEARANCES AROUND ALL NEW AND EXISTING ELECTRICAL <br />EQUIPMENT SHALL COMPLY WITH CEC 110.26. <br />·DRAWINGS INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS. <br />CONTRACTOR SHALL FURNISH ALL NECESSARY OUTLETS, SUPPORTS, <br />FITTINGS AND ACCESSORIES TO FULFILL APPLICABLE CODES AND <br />STANDARDS. <br />·WHERE SIZES OF JUNCTION BOXES, RACEWAYS, AND CONDUITS ARE NOT <br />SPECIFIED, THE CONTRACTOR SHALL SIZE THEM ACCORDINGLY. <br />·ALL WIRE TERMINATIONS SHALL BE APPROPRIATELY LABELED AND <br />READILY VISIBLE. <br />·MODULE GROUNDING CLIPS TO BE INSTALLED BETWEEN MODULE FRAME <br />AND MODULE SUPPORT RAIL, PER THE GROUNDING CLIP <br />MANUFACTURER'S INSTRUCTION. <br />·MODULE SUPPORT RAIL TO BE BONDED TO CONTINUOUS COPPER E.G.C. <br />VIA WEEB LUG OR ILSCO GBL-4DBT LAY-IN LUG. <br />·THE POLARITY OF THE GROUNDED CONDUCTORS IS NEGATIVE <br />11 MODULES-ROOF MOUNTED - 4.455 kWDC, 4.036 CEC kWAC <br />1425 W RIVER LN, SANTA ANA, CA 92706, USA <br />SYSTEM SUMMARY <br />(N) 11 - JA SOLAR JAM54S31-405/MR (405W) MODULES <br />(N) 11 - ENPHASE ENERGY IQ8HC-72-M-DOM-US [240V] [SI1-SB] MICRO-INVERTERS <br />(N) JUNCTION BOX <br />(N) ENPHASE IQ COMBINER BOX 5 (X-IQ-AM1-240-5) <br />(E) 225A MAIN SERVICE PANEL WITH (E) 200A MAIN BREAKER <br />(N) 60A NON-FUSED VISIBLE OPEN LOCKABLE AC DISCONNECT [240V] <br />(N) 2 - ENPHASE ENERGY INC./IQ BATTERY-5P-1P-NA-DOM [240V] [SI1-SB] <br />(N) 60A NON-FUSED EMERGENCY DISCONNECT <br />(N) 100A SOLAR LOAD CENTER <br />DESIGN CRITERIA <br />ROOF TYPE: ASPHALT SHINGLE <br />NUMBER OF LAYERS: 1 <br />ROOF FRAME: 2"X4" RAFTERS @ 24" O.C <br />STORY: ONE STORY <br />SNOW LOAD: 0 PSF <br />WIND SPEED: 95 MPH <br />WIND EXPOSURE: B <br />RISK CATEGORY: II <br />COORDINATE: 33.770521, -117.887326 <br />GOVERNING CODES: <br />2022 CALIFORNIA ELECTRICAL CODE (CEC) <br />2022 CALIFORNIA BUILDING CODE (CBC) <br />2022 CALIFORNIA EXISTING BUILDING CODE (CEBC) <br />2022 CALIFORNIA RESIDENTIAL CODE (CRC) <br />2022 CALIFORNIA GREEN CODE (CGC) <br />2022 CALIFORNIA MECHANICAL CODE (CMC) <br />2022 CALIFORNIA ENERGY CODE (CENC) <br />2022 CALIFORNIA PLUMBING CODE (CPC) <br />2022 CALIFORNIA FIRE CODE TITLE 24 SUPPLEMENT <br />ANY OTHER LOCAL AMENDMENTS <br />EXISTING SYSTEM SUMMARY: <br />(E) 22 KYOCERA KU265-6ZPA (265W) PV MODULES <br />(E) 1 - TESLA INVERTER <br />(E) AC DISCONNECT <br />A <br />A <br />07 Aug 2025 <br />EXP : 30 Sep 2025 <br />STRUCTURAL ONLY <br />***The scope of the plans is <br />for the installation of the <br />solar photovoltaic system <br />only and the approval is <br />subject to compliance with <br />all applicable city and state <br />codes and regulations <br />regarding construction. The <br />approval of the plans does <br />not constitute any <br />certification of the accuracy, <br />completeness, or building <br />permit status of the existing <br />buildings and structures as <br />shown.*** <br />Elect #20186400 <br />APPROVALS: <br />ELECT - M. Smith
The URL can be used to link to this page
Your browser does not support the video tag.