Laserfiche WebLink
NTETRATECH <br />Victor M. Ramirez, PE, SE. <br />Structural Lead <br />Mr. Ramirez has over 30 years of structural engineering design <br />experience with special emphasis In the design of water <br />storage/water containment and water conveyance related <br />structures, This Includes reservoirs, water/wastewater treatment <br />plants, booster pump stations, flow control facilities, pressure <br />reducing stations and pipelines. His experience also includes the <br />design of a wide variety of other types of structures, including <br />buildings, bridges and storm drainage related structures, He is <br />thoroughly knowledgeable in all types of construction, including <br />reinforced concrete:, masonry, structural steel, and timber. <br />EXPERIENCE <br />Mid -Basin Injection: Centennial Park. Design Services, Orange <br />County Water District, Santa Ana, CA ._ Structural Project <br />Manager responsible for the design :of four injection wells to be <br />located within Centennial Park in the City of Santa Ana for Orange <br />County Water District. In addition to the engineering services for <br />the four injection welts the project includes the design of the <br />supply pipeline, backflush pipeline, bridge crossing, two shared <br />facility sites, a monitoring well site, site improvements, and paving <br />of park access roads and parking lots. <br />Design -Build of Wells 21 and 22 Desalter, Irvine Water office: <br />District, Irvine, CA — Structural Project Engineer for a project that sal, Dimas, California <br />is the thirdmembrane water treatment plant completed by the years of Exporlence: <br />design/build team of Tetra Tech and Pascal & Ludwig. The main gg <br />treatment facility Is housed in a 10,000 square foot tilt -up concrete <br />building which also contains pump, control, HVAC and electrical Years with Tetra Tech: <br />roorns, A corner of the building is constructed on a 12 foot deep, 36 <br />100,000 gallon, buried, cast -in -place concrete water storage <br />structure. Special consideration was given in the analysis and <br />detailing of the tilt -up building and buried concrete structure so <br />that all design forces are properly resisted and the potential <br />differential settlement between the shallow building foundations and the deep water storage <br />structure is mitigated. Various concrete and steel structures for pre- and post -treatment areas <br />are also located on the site. These areas are hidden from public view by 27 foot tall freestanding <br />Ulf -up concrete screen waits and by the main treatment building itself. <br />Burris Pump Station, Orange County Water District (OCWD), Anaheim, CA — Structural <br />Engineer for the replacement of an existing pumping facility at the Burris Pump Station location. <br />Mr. Ramirez was involved in the comprehensive design of the O.6 MG buried circular wet well. <br />The new facility will allow OCWD to transfer up to 200 cubic feet per second from the Santa Ana <br />River, which will be and utilized for groundwater recharge to the Santiago Basins, <br />Welts No. 40 and 44, City of Ontario, CA — Project consisted of two new domestic water wells <br />approximately 1,200 feet deep. Well capacities are 2,000 to 3,000 gpm, Included masonry block <br />enclosure with open roof courtyard, Also included disinfection and construction administration <br />Education: <br />B,S, Civil Engineering, <br />Cdliforniw $late University, <br />Los Angeles,1996 <br />Registrations/Certifications: <br />Registered Structural <br />Engineer <br />California, 2004, No, 4720 <br />Registered CIuiI Engineer <br />California,1907, No. 666119 <br />Page 1 <br />Professional Affiliations: <br />Structural Engineers <br />Association of Southern <br />Californla <br />American Institute of Stool <br />Construction <br />Field Safety Certifioations <br />Confined Space <br />Fall Protection <br />