My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
75E - PH 2525 MAIN ST
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2019
>
02/05/2019
>
75E - PH 2525 MAIN ST
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2019 4:04:49 PM
Creation date
2/1/2019 3:58:07 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Planning & Building
Item #
75E
Date
2/5/2019
Destruction Year
2024
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
378
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXHIBIT A <br />With the implementation of the mitigation measure identified above (MM-HAZ-1), the Project's potential <br />impacts relating to hazards and hazardous materials would be less than significant. (DEIR, pp. 4.6-7 <br />through 4.6-8.) <br />8.4 Noise <br />8.4.1 Noise Levels in Excess of Established Standards <br />Threshold: Would the Project result in exposure of persons to or generation of noise levels in <br />excess of standards established in the local general plan or noise ordinance, or applicable standards of <br />other agencies? <br />Finding: Less than significant impact with mitigation incorporated. (DEIR, pp. 4.8-10 through 4.8-13.) <br />Facts in Support of Findings: The Project would not result in generation of noise levels in excess <br />standards established by the City's Municipal Code. Per Section 18-314 (Special Provisions) of the City's <br />Municipal Code noise sources associated with construction activities are exempt from the established <br />noise standards as long as the activities do not take place between the hours of 8:00 p.m. and 7:00 a.m. on <br />weekdays, including Saturday, or any time on Sunday or a federal holiday. The Project's construction <br />activities would occur pursuant to these regulations. Thus, the Project would be in compliance with the <br />City's construction related noise standards. <br />However, the Project has the potential to result in exposure of persons to noise levels in excess of relevant <br />standards as a result of increased traffic -related noise. As discussed in the DEIR, traffic along the roadways <br />near the Project site would generate noise that could exceed interior noise standards within some of the <br />Project units. Thus, some of the residential units would require upgraded windows and sliding glass doors <br />with increased Sound Transmission Class (STC) ratings to meet the interior noise standards. As described <br />in Section 4.8, Noise, of the DEIR, the residential units along N. Main Street would require upgraded <br />windows and sliding glass doors with minimum STC ratings of between 27 and 30 to meet the interior <br />noise standards. Mitigation Measure NOH would ensure that the appropriate windows and doors are <br />installed, which would reduce impacts to a less than significant level. (DEIR, pp. 4.8-10 through 4.8-13.) <br />Mitigation Measure N0I-1: The Project plans and specifications shall include the following <br />construction requirements to be implemented and verified prior to provision of occupancy permits: <br />• Windows/Glass Doors: Residential units adjacent to N. Main Street (all floors) require upgraded <br />windows and sliding glass doors (all windows/doors on all floors) with minimum STC ratings of <br />30; and all other buildings require standards windows and sliding glass doors with a minimum <br />STC rating of 27. <br />Exterior Doors (Non -Glass): Exterior doors facing N. Main Street (all floors) require upgraded <br />exterior doors with minimum STC ratings of 30 and shall be well weather-stripped; and all other <br />residential building exterior doors shall be well weather-stripped and have minimum STC ratings <br />of 27. Well -sealed perimeter gaps around the doors are essential to achieve the optimal STC rating. <br />Walls: At any penetrations of exterior walls by pipes, ducts, or conduits, the space between the <br />wall and pipes, ducts, or conduits shall be caulked or filled with mortar to form an airtight seal. <br />Resolution No. <br />Certification of the Magnolia at the Park EIR <br />75E-53 <br />Page 15 of 71 <br />
The URL can be used to link to this page
Your browser does not support the video tag.