My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
80A - JOINT WORK CENTER MOU
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2019
>
05/07/2019
>
80A - JOINT WORK CENTER MOU
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2022 11:33:23 AM
Creation date
5/2/2019 6:11:42 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Community Development
Item #
80A
Date
5/7/2019
Destruction Year
2024
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
722
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EXHIBIT 3 <br />DIVISION 4 — REFERENCE FORMS <br />Office of the State Fire Marshal <br />Sample Plan Review Triage List <br />This form is provided for informational patposes only. For the complete triage list visit the website below. <br />Information andforms may be obtained at Office of the State Fire Marshal, Fire and Life Safety Division - Plan Review Seadon <br />www. ostna, /ire. ca, gav <br />1. GENERAL <br />o Height increase <br />❑ Provide a complete plan review <br />o Fire Sprinklers (Type, Full, Partial) <br />application Submit plans sufficient size <br />a Fire Alarm (Type) <br />o Other Fire Protection System (Type) <br />❑ Provide site address <br />o Smoke Control System (Y/N) <br />❑ Provide name of owner and occupant <br />o Occupant load for entire building and <br />❑ Identify if new construction or T.I. <br />each oor <br />❑ Identify It new or existing tenant space <br />uildi <br />Year building was constructed <br />❑ Identify if deferred submittal <br />c <br />o High Fire Hazard Severity Zone <br />❑ CSFM file number must be on title <br />o Seismic Joints and locations (Y/N) <br />O <br />sheet <br />❑ Slip sheets shall be bound to set <br />o Emergency Responder Radio Coverage <br />❑ Sheet index <br />❑ <br />�/N) <br />Identify occupancy groups/uses on floor <br />❑ Wet stamp and sign sheets <br />plans <br />❑ Electronic signature approval <br />❑ <br />Identify adjacent buildings on the site <br />required <br />❑ <br />Identify fire separation distances <br />❑ Scope of Work <br />❑ <br />Identify building allowable area increases <br />❑ Provide a Key Plan coordinated to each <br />❑ <br />Justify frontage allowances <br />sheet <br />❑ <br />Sprinkler heightlarea increase cannot be <br />❑ Provide a North orientated Site <br />combined <br />Map <br />❑ Orientate all sheets to North <br />❑ <br />Identify types and materials of all construction <br />❑ Identify deferred submittals <br />o Provide wall legends <br />o Fire rated assemblies <br />❑ Provide adopted code cycle listings and <br />o Scan listed assemblies to plans <br />standards <br />❑ <br />Penetration protection <br />❑ Provide a legible scale. Typically1/8" <br />o Scan listed fire stopping systems to plans <br />❑ Provide approved reference <br />o Classification of roof covering <br />❑ <br />Details for opening protection <br />2. ACCESS AND WATER SUPPLY <br />o Door schedule <br />❑ Provide Local Fire Authority Approval Letter <br />❑ <br />Window schedule <br />❑ Fire Department <br />p <br />❑ <br />Louver schedule <br />❑ Fire Department Connection <br />❑ <br />Listed smoke containment system <br />❑ Fire Hydrants <br />❑ <br />Interior finish smoke and flame spread <br />❑ Fire Alarm Annunciator <br />4. EXITING <br />❑ Fire Alarm Control Panel <br />❑ <br />Paths of travel to a public way <br />❑ Knox BoxJKsy Switch <br />❑ <br />All occupancies/uses on floor plans <br />❑ Emergency Responder Radio Coverage <br />❑ <br />Correct occupant load factors (gross, net) <br />❑ Elevator gurney accommodation <br />❑ Provide a complete fire access plan <br />❑ <br />Cumulative loads (lobbies, corridors, stairs, <br />❑ Provide 6 mo, current site fire flow information <br />etc.) <br />❑ <br />Furniture plan <br />3. NONSTRUCTURAL PROVISIONS <br />❑ <br />Egress capacity (width and number) <br />❑ Building Analysis (include the following) <br />❑ <br />Door swing <br />o Occupancy groups and varied uses <br />❑ <br />Door hardware <br />o Building construction type <br />❑ <br />Delayed egress design <br />o Number of stories <br />❑ <br />Card readers/ access control <br />o Actual building height <br />❑ <br />Emergency lighting and photometric <br />o Building area in square feet <br />❑ <br />Exit signs <br />o Area of project in square feet <br />❑ <br />Exit enclosures (vertical and horizontal) <br />o Separated, non -separated, accessory use <br />❑ <br />Exit discharge <br />o Allowable area <br />❑ <br />Areas of refuge & Safe dispersal areas <br />o Area increase <br />10 <br />iRavaitsi <br />80A-652 <br />
The URL can be used to link to this page
Your browser does not support the video tag.