Laserfiche WebLink
EXHIBIT 3 <br />DIVISION 4- REFERENCE FORMS <br />5. FIRE PROTECTION SYSTEMS <br />• FIREALARM <br />❑ Provide highlighted set of data sheets <br />❑ Provide cut sheets for all components <br />❑ Provide current CSFM listings <br />Provide/correct equipment matrix <br />❑ Provide a sequence of operation Identify <br />approved monitoring station <br />❑ Identify fire alarm and egress -control <br />devices <br />❑ Demonstrate compliance for egress -control <br />systems <br />❑ Provide ceiling configuration, surface, and <br />height <br />❑ Provide/correct voltage drop calculations for <br />devices <br />❑ Provide/correct riser diagram <br />❑ Provide/correct standby battery calculations <br />❑ Demonstrate audible visual notification <br />coverage <br />❑ Demonstrate manual fire alarm box coverage <br />• FIRE SPRINKLERS <br />❑ Provide all OSFM shop drawing notes <br />❑ Submittal shall comply with OSFM design <br />guideline <br />❑ Identify system type (wet, dry, pre -action, <br />etc.) <br />❑ Provide ceiling configuration, surface, and <br />height <br />❑ Provide hydraulic calculations <br />❑ Provide full height cross sections/ceiling <br />construction <br />❑ Identify area protected by each system for <br />each floor <br />❑ Identify area limitations for hazard <br />classifications <br />❑ Correct notes/design to reflect CA <br />amendments <br />❑ Identify miscellaneous storage condition <br />6. HOOD AND DUCT EQUIPMENT/SYSTEMS <br />❑ Scaled plan of area and equipment <br />❑ Dimensions of hoods, ducts, and appliances <br />❑ Equipment list for system, devices and <br />materials <br />❑ Manufacturer's installation instructions <br />❑ Cut sheets and compliance with UL 300 <br />Standard <br />❑ Isometric drawing of piping and components <br />o Type, size and length of piping <br />o Size and number of fittings <br />o Model number and locations of nozzles <br />o Location, temperature and model of <br />detectors <br />o Location and size of extinguishing agent <br />o Location of manual means of activation <br />o Location and Identity of gas and electric <br />shutoffs <br />o Interconnection to building fire alarm system <br />o Location of a Class K fire extinguisher <br />7. ELECTRIC VEHICLE CHARGING STATIONS <br />❑ Identify required signage, posts, wheel stops <br />❑ Identify electrical panel bonding and <br />grounding <br />❑ Provide location of disconnect <br />❑ Charging equipment for vehicles requiring <br />ventilation <br />❑ Identify means of indoor mechanical <br />ventilation <br />❑ Provide details for underground runs. <br />❑ (Trench depths, conduit/conductor sizes) <br />8. HAZARDOUS MATERIALS <br />❑ Inventory summary with hazard class and <br />totals <br />❑ Safety Data Sheets <br />❑ Floor plans <br />❑ Occupancy classifications <br />❑ Control areas <br />❑ Fire resistive construction <br />❑ Hazardous materials warning signs <br />❑ No smoking signs <br />❑ Hazardous materials alarm devices <br />❑ Hazardous materials cabinets Fume hoods <br />and enclosures <br />❑ Equipment utilizing hazardous materials <br />❑ Spill control/secondary containment <br />❑ Standby/emergency power <br />9. HIGH PILE STORAGE <br />❑ Letter of intent signed by authorized <br />department head <br />❑ HIPS analysis prepared by a FPE <br />❑ Scaled site plan (fire lanes, hydrants, FDC's, <br />risers) <br />❑ Scaled floor plan (HIPS area, racks, access <br />doors) <br />❑ Fire sprinkler design density <br />❑ Aisle dimensions <br />❑ Dimensions and location of flue spaces <br />❑ Location of different commodity classes <br />❑ Location of banded/encapsulated storage <br />❑ Location and type of building columns <br />❑ Fire resistive construction <br />❑ Occupancy classification of adjacent tenants <br />❑ Location and design of smoke vents <br />11 <br />(Rev-a/tg) <br />80A-653 <br />