My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
NS-2970
Clerk
>
Ordinances
>
2011 - 2020 (NS-2813 - NS-3000)
>
2019 (NS-2963 - NS-2978
>
NS-2970
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/18/2019 5:07:31 PM
Creation date
7/18/2019 5:02:15 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Ordinance
Doc #
NS-2970
Date
7/16/2019
Destruction Year
P
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
T R A N S I T Z O N I N G C O D E : Architectural Standards - Building Types <br />Illustrative Axonometric Diagram <br />Illustrative Photo: Hybrid Court courtyard <br />Illustrative Photo: Hybrid Court access to the second level <br />Sec. 41-202S. Hybrid Court Building Type. <br />(a) Hybrid Court is a building composed of two building types, the stacked dwelling and couryard <br />housing, arranged around a courtyard(s). This building type combines a point access portion <br />of the stacked dwelling building type (access through a double loaded corridor) with a walk-up <br />portion of the courtyard housing building type (access directly from the street or courtyard). <br />The building may be designed for occupancy by retail, service, or office uses on the ground <br />floor, with upper floors also configured for those uses or for residences <br />(b) Lot Width and Depth. <br />shall be 250 feet. The depth of ffie lot shall be a D i Do fl of 200 . The minimum and maxi- <br />mum lot width and the minimum lot depth shall be as prescribed in TableBT-1 (Permitted <br />(1) The main entrance to each ground floor unit shall be directly from the street. <br />(2) Entrance to the residential portions of the stacked dwelling element shall be through a <br />dedicated street level lobby, or through a dedicated podium lobby accessible from the <br />street or through a side yard. <br />(3) Access to each unit above the second level in the stacked dwelling element not accessed <br />from the podium is through an interior, double -loaded corridor of at least 6 feet in width <br />with recessed doors or sealing alcoves/offsets at least every 100 feet. For other units, <br />access shall be directly off a common courtyard or through stairs serving up to 3 dwell- <br />ings. <br />(4) Elevator access shall be provided between the garage and each level of the stacked dwell- <br />ings portion of the building. <br />(d) Parking Standards <br />(1) Required parking shall be accommodated in an underground garage, surface parking, <br />tuck under parking, or a combination thereof. <br />(2) Dwellings shall have indirect access to their parking stall(s). <br />(e) Service Standards <br />(1) Utility meters shall be screened from view from the street and shall not be located within <br />any required landscape or setback area. <br />(2) Mail boxes shall not be located in any required open space, landscape or setback areas or <br />detract from the primary entrance to the development. <br />(f) Open Space Standards <br />(1) The common open space shall be designed as a central courtyard or partial, multiple, <br />separated or interconnected courtyards. This area shall equal to 15 percent of the lot and <br />shall be open to the sky. Courtyards may be located on the ground or on a podium. Side <br />yards may be formed as common use gardens. <br />(2) Minimum courtyard dimension is 40 feetwhen the long axis of the courtyard is oriented <br />EW and 30 feet for a NS orientation. Courtyard proportions shall not be less than 1:1 <br />between the width of the courtyard and the height of the building for at least 2/3 of the <br />court's perimeter. Horizontal shifts in upper floors adjacent to a court shall not exceed 12 <br />the height of each upper floor. <br />(3) In 40 foot wide courtyards, frontages and architectural projections are permitted on two <br />opposing sides of the courtyard provided that an overall minimum width of 40 feet is <br />maintained. Frontages and architectural projections are permitted on one side of a 30 <br />foot wide courtyard provided an overall minimum width of 30 feet is maintained. <br />(4) Private open space is required for each residential unit and shall be no less than 50 square <br />feet with a minimum dimension of feet in each direction. <br />(5) Private open space may be substituted for additional common open space or common <br />interior space, the size of which will be equivalent to the displaced private open space. <br />The minimum dimension of this space shall be 15 feet in each direction. <br />(g) Landscape Standards <br />(1) Where a front yard is present, one (1) 24-inch box tree per 25lineal feet shall be planted. <br />The trees may be placed in groups in order to achieve a particular design. <br />(2) Courtyards located over garages shall be designed to avoid the sensation of forced podi- <br />um hardscape. <br />(3) Side yard trees shall be placed to create a particular sense of place at a rate of one (1) <br />24-inch box tree per 30 lineal feet. <br />(4) One 36-inch box specimen tree is required per courtyard that meets the minimum dimen- <br />sions. For courtyards that exceed the minimum dimensions, two or more 24-inch box <br />smaller size trees may be substituted for the 36-inch box tree. <br />(5) Six (6) 5-gallon size shrubs, ten (10) one -gallon size herbaceous perennials/shrubs and turf <br />or acceptable dry climate ground cover shall be planted for every required tree. <br />(6) In the rear yard, at least one (1) 24-inch box canopy tree per every 25lineal feet planted <br />directly in the ground. <br />(7) Front yard trees shall be of small scale that shall not exceed 12-15' height at maturity and <br />are suitable for built-in concrete planters or containers with a 36" minimum width. <br />(h) Frontage Standards <br />(1) Entrance doors and social rooms, such as living rooms and dining rooms are oriented <br />fronting toward the courtyard(s) or the street when fronting one. Service rooms are ori- <br />ented to the degree possible backing to corridors in the Stacked Dwellings portion and to <br />side yards, service yards and rear yards in the courtyard housing portion. <br />(2) Stoops up to feet in height may be placed above subterranean parking, provided the <br />area adjacent is landscaped and the stoops are scaled to the street and building. <br />(i) Building Size and Massing Standards <br />(1) Each unit shall have at least one side exposed to the outdoors with direct access private <br />or common open space. <br />(2) Buildings may contain any of three types of dwellings: flats, townhouses and lofts. <br />(3) Units may be as repetitive or unique as deemed by individual designs. <br />4.13 TRANSIT ZONING CODE <br />SPECIFIC DEVELOPMENT 84 <br />City of Santa Ana, California <br />
The URL can be used to link to this page
Your browser does not support the video tag.