Laserfiche WebLink
EXHIBIT A <br />Resolution No. _____ Page 20 of 76 <br />Certification of the Magnolia at the Park EIR <br />Facts in Support of Findings: Construction of the Project would generate short-term periodic increases <br />in ambient noise levels at sensitive receptors in the Project vicinity. With implementation of Mitigation <br />Measure NOI-2, noise from operation of large mobile construction equipment (greater than 80,000 <br />pounds) and loaded trucks would be reduced; and Mitigation Measure NOI-3 is included to require <br />installation of a temporary noise barrier that would be a minimum 11-feet high, constructed of frame- <br />mounted materials such as vinyl acoustic curtains or quilted blankets, and attached to the masonry wall <br />along the eastern Project site boundary or temporary fence posts. In addition, due to the location of existing <br />sensitive receptors, Mitigation Measures NOI-2 and NOI-3 would require a 50-foot setback for use of <br />large mobile construction equipment and require installation of a temporary noise barrier, which would <br />reduce the temporary and intermittent increase in noise from construction to a less than significant level. <br /> <br />With implementation of Mitigation Measures NOI-2 and NOI-3 temporary and periodic construction noise <br />level increases at receiver locations would be reduced to below the 10 dBA Leq temporary noise level <br />increase threshold. Therefore, with implementation of mitigation, impacts related to periodic temporary <br />increases in noise would be less than significant. <br /> <br />To ensure that the Project’s potential impacts relating to temporary increases in ambient noise levels are <br />mitigated to a less than significant level, in addition to Mitigation Measure NOI-2, discussed above, the <br />following mitigation measure has been identified: <br /> <br />Mitigation Measure NOI-3: The Project plans and specifications shall include the requirement to install <br />a minimum 11-foot high temporary construction noise barrier along the Project site eastern boundary for <br />the duration of Project construction. The noise control barriers shall have a solid face from top to bottom <br />and shall meet the following height and constructed requirements: <br />• The temporary noise barrier shall provide a minimum transmission loss of 20 dBA (Federal <br />Highway Administration, Noise Barrier Design Handbook). The noise barrier shall be constructed <br />using an acoustical blanket (e.g. vinyl acoustic curtains or quilted blankets) attached to the <br />construction site perimeter fence or temporary fence posts. <br />• The noise barrier shall be maintained, and any damage promptly repaired. Gaps, holes, or <br />weaknesses in the barrier or openings between the barrier and the ground shall be promptly <br />repaired; <br />• The noise control barrier and associated elements shall be completely removed, and the site <br />appropriately restored upon the conclusion of the construction activity. <br /> <br />With the implementation of the mitigation measures identified above (MM-NOI-2 and MM-NOI-3), the <br />Project’s potential impacts relating to temporary increases in ambient noise levels would be less than <br />significant. (DEIR, pp. 4.8-16 through 4.8-17.) <br /> <br />The Modified Project would involve the same types of construction equipment that would be operated in <br />similar locations as the Original Project. However, the building setback along the eastern side of the <br />project site would be 50 feet greater. Thus, construction of building structures would be farther from the <br />residences located to the east of the Project site. However, consistent with the Original Project, Mitigation <br />Measures NOI-2 and NOI-3 would be required to prohibit the use of large mobile equipment and loaded <br />trucks within 50 feet of the residences to the east of the Project site and install a temporary noise barrier <br />to reduce the temporary increase in ambient noise to a less than significant level. No new or greater impacts <br />2-50