Laserfiche WebLink
O TETRATECH Mike Olsen, PE <br />Structural Project Engineer <br />Mr. Olsen has been a part of the Tetra Tech team for over eight years and contributes <br />Education: <br />his extensive structural engineering knowledge from his involvement in municipal, <br />MS, Civil Engineering (Structural <br />industrial and federal projects. He has completed a variety of projects varying in size <br />Emphasis), California State <br />Polytechnic University, Pomona, <br />and funding for both public and private entities. <br />2016 <br />Mr. Olsen's experience includes design, analysis, detailing and construction in <br />BS, Civil Engineering, California <br />structural engineering. He is knowledgeable in reinforced concrete, pre- and post- <br />State Polytechnic University, <br />tensioned concrete, reinforced masonry, steel and timber construction for a variety of <br />Pomona, 2009 <br />Magna Cum Laude <br />building and infrastructure projects including reservoirs, water/wastewater treatment <br />facilities, pump stations, bridge, buried concrete vaults, pipeline structures, bridges, as <br />Registrations/Certifications: <br />Professional Engineer, <br />well as seismic retrofit of existing structures. Mr. Olsen has extensive working <br />California, No. 81944, 2013 <br />knowledge of the California Building Code (CBC), International Building Code (IBC) <br />and their application to civil and structural engineering projects. <br />Cal OES Safety Assessment <br />Program Evaluator <br />Mr. Olsen is experienced with a variety of design software programs including RISA- <br />Professional Affiliations: <br />3D, RISA Foundation, RISA Floor, ENERCALC SEL, L-PILE, RetainPro and Hilti <br />Chi Epsilon- Civil Engineering <br />PROF IS Anchor. <br />Honor Society - Cal Poly <br />Pomona <br />EXPERIENCE <br />Tau Beta Pi -Engineering Honor <br />Structural Analysis of the Mira Flores No. I Reservoir, Golden State Water <br />Society - Cal Poly Pomona <br />Company, Santa Maria, CA. 2016. Structural Design Engineer providing <br />Structural Engineering Institute <br />professional engineering services for their 0.3 MG tank. The Mira Flores No. I <br />(SEI) and Member of ASCE <br />Reservoir is a rectangular semi -buried concrete masonry unit (CMU) water tank with a <br />Office Location: <br />capacity of 0.3 MG. It measures approximately 82-feet by 42-feet with a depth of 15- <br />Irvine, CA <br />feet. The reservoir has a wooden roof structure with skid mounted vertical turbine <br />Total Years of Experience: <br />booster station located on top of the roof at the rear of the tank. Recent inspection <br />(2011) 8 <br />showed that the roof reservoir is failing and needs replacement. Concerns regarding <br />Years with Tetra Tech: <br />cracks in the concrete (cinder block) walls indicate that significant work will be <br />(08/2011) 8 <br />required to reinforce the existing structure before re -roofing with a new aluminum roof <br />and remounting the vertical turbine pumps. <br />Sierra Madre Reservoir Rehabilitation, City of Glendora, Glendora, CA. 2015. Structural Design Engineer for the <br />structural analysis of an existing 4 MG pre -stressed concrete reservoir constructed in 1964-65. The goal of the project was <br />to bring the reservoir up to current standards. The main issues with the reservoir were a cracked and sagging concrete roof <br />and cracking and spalling of exterior gunite and concrete interior walls, columns, and floor. <br />Reynolds Ranch, City of Vacaville, CA. 2015. Structural Design Engineer for preliminary design report of a new pre- <br />stressed concrete 0.53 MG reservoir and 490 grim booster pump station. The report evaluated alternative configurations, <br />layout, operations, geotechnical conditions, seismic constraints, community impacts, and environmental issues. Pump <br />station design incorporated a 50 hp two -pump booster station with motor control center, standby generator, and <br />instrumentation. Permitting and assistance during bidding and construction was also provided. <br />Structural and Seismic Evaluation of Storage Reservoirs, Montecito Water District, Montecito, CA. 2014 — 2015. <br />Structural Design Engineer. Conducted condition assessments, inspections, investigations, performed testing and provided <br />structural and seismic analysis of nine District water storage reservoirs with a combined volume of 11.5 million gallons at <br />full capacity. The nine reservoirs included five rectangular predominately buried concrete reservoirs, three circular above <br />ground concrete reservoirs, and one circular above ground steel reservoir. Deficiencies identified were presented with <br />prioritized alternatives for repair(s), retrofit or replacement to ensure these facilities continued to operate and provide water <br />following a seismic event. The District provides potable water to approximately 4,360 customer accounts that use an <br />average 5.5 million gallons of water per day. <br />Plant 224 Reservoirs and Pump Station, Suburban Water System, City of Whittier, CA. 2012 —2014. Structural <br />Design Engineer for the design and construction of two rectangular, conventionally reinforced concrete reservoirs with a <br />total capacity of 7.0 MG. The design included architectural treatment that features a street -front architectural fagade, as well <br />as interior and exterior roof access stairs. <br />Rawlings Reservoirs, City of Tustin, Tustin, CA. 2012. Structural Design Engineer for two pre -stressed, circular 3.5 MG <br />concrete tanks located on a confined site, where space for excavation and material stockpiling during construction presented <br />Page 1 <br />