Hui "Harry" Wu
<br />Structural Engineer
<br />Education
<br />Dr. Wu is an experienced structural engineer and for the last three years has worked
<br />PhD, Structural
<br />exclusively on water and wastewater infrastructure projects including water storage. He
<br />Engineering, University
<br />is an expert in earthquake resistant design of structural systems (reinforced concrete,
<br />of Southern California,
<br />masonry, steel, and wood), tilt -up structural design, seismic retrofit design of structures,
<br />Los Angeles, California
<br />structural analysis, finite element analysis. Dr. Wu is also well versed in industry standard
<br />MS, Structural
<br />modeling programs used in structural engineering and an encyclopedia of current
<br />Engineering, Tsinghua
<br />building code requirements for reinforced concrete: ACI 318-14, for Steel AISC 360-16,
<br />University
<br />ASD, LRFD Manual, and IBC-2015, CBC-2016, ASCE 7-16. He performs large scale seismic
<br />BS, Structural
<br />testing of structural components and assemblies in reinforced concrete and steel.
<br />Engineering, Beijing
<br />Professional Record
<br />Institute of Civil
<br />Engineering and
<br />Morro Hills Prestressed Concrete Reservoir Construction Phase Services, City of
<br />Architecture, Beijing,
<br />Oceanside, Oceanside, California. Structural engineer for one of nine projects for the
<br />China
<br />City of Oceanside Reservoir Repairs contract. Services included structural engineering
<br />analysis to define additional details specific to the site, apply site specific parameters
<br />Registrations
<br />from the geotechnical investigations, and develop design alternatives and final detailed
<br />PE, Civil Engineering,
<br />design for structural repairs and upgrades.
<br />California No. C68210
<br />Seismic Retrofit of Two Reinforced Concrete Tanks, California Water Service, San
<br />Affiliations
<br />Carlos, California. Structural engineer for a design build project in the highly seismic
<br />Concrete Reinforcing
<br />area of San Carlos. Project involved a seismic retrofit of two prestressed concrete water
<br />Steel Institute
<br />reservoirs and a pump station.
<br />Sand Hill Reservoir No. 2 Roof Replacement, City of Menlo Park, Menlo Park,
<br />Expertise
<br />California. Structural engineer providing roof -replacement design and engineering
<br />Earthquake resistant
<br />services for a reservoir roof that was at the end of its useful life. It had started sagging
<br />design of structure
<br />and water was ponding on the flat roof of the trapezoidal reservoir. Structural
<br />systems (reinforced
<br />connections and joist were coming loose and water was penetrating through the roof
<br />concrete and
<br />causing the wood to rot. Dr. Wu provided seismic evaluation and analysis services,
<br />masonry)
<br />identified design alternatives, and assisted in the preparation of the final design for the
<br />Seismic retrofit
<br />new roof construction including installation of new mixers in Sand Hill Reservoir Nos. 1
<br />design of structures
<br />and 2.
<br />Structural analysis,
<br />LA Reservoir Ultraviolet Disinfection Plant, City of Los Angeles, Department of
<br />finite element
<br />Public Works, Los Angeles, California. Structural engineer for the structural design of a
<br />analysis
<br />steel -framed building with lateral force -resisting system subjected to site -specific seismic
<br />spectrum and code -specified wind force. Provided the structural design for other
<br />Large scale seismic
<br />structural components including RC slab, trenches, valve vaults, return sumps, and trunk
<br />testing of structural
<br />line encasements considering static and dynamic soil pressure and buoyancy.
<br />components and
<br />assemblies of
<br />Dekoven Tank Replacement Project, Mid -Peninsula Water District, Belmont,
<br />reinforced concrete
<br />California. Structural engineer for the replacement of two steel water tanks in a tightly -
<br />pocketed and seismically sensitive area hillsides north of South San Francisco. Will also
<br />Telephone
<br />be providing services during construction.
<br />(828) 376-3410
<br />As -Needed Structural Design Services, Eastern Municipal Water District, Perris,
<br />Email
<br />California. Structural engineer for as -needed task orders including a condition
<br />hwu@beyazpatel.com
<br />assessment at the Hemet Water Reclamation Plant for a cracked beam and loading dock
<br />roll -up door.
<br />
|