My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
OPAL FUELS STATION SERVICES, LLC (FROMERLY TRUSTAR ENERGY, LLC) (3)
Clerk
>
Contracts / Agreements
>
O
>
OPAL FUELS STATION SERVICES, LLC (FROMERLY TRUSTAR ENERGY, LLC) (3)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/19/2024 10:30:55 AM
Creation date
4/10/2023 11:54:44 AM
Metadata
Fields
Template:
Contracts
Company Name
OPAL FUELS STATION SERVICES, LLC (FROMERLY TRUSTAR ENERGY, LLC)
Contract #
A-2022-245
Agency
Public Works
Council Approval Date
12/20/2022
Expiration Date
9/30/2032
Insurance Exp Date
1/1/2024
Destruction Year
2037
Notes
For Insurance Exp. Date see Notice of Compliance
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
21
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SERVICE AGREEMENT - ALL INCLUSIVE t00% WARRANTY <br />• Check and drain inlet filters <br />• Check valve sequencing <br />• Visually inspect all pressure relief devices for signs of failure or leakage <br />• Verify ESD control functions and safety equipment <br />• Verify on/off switch operations <br />• Verify ESD control fimctions <br />• Verify 4,250-psig maximum fill pressure limits <br />Dispensers -Time Pill <br />• Visually inspect tubing, piping, mid valves for leaks and abnormalities <br />• Check and drain inlet filters <br />• Verify ESD control functions and safety equipment <br />Methane Gas Detection Sensors <br />• Verify and test operations <br />• Test equipment to meet OEM design criteria <br />• Repair and replace defective equipment <br />Inlet Gas Dryer <br />• Monthly - Drain pre -filter, blower house, and sump <br />• Monthly - check differential pressure across pre -filter and after -filter elements. Replace if <br />required when gauge is approaching red zone or 3-5 PSID <br />• Monthly - check dewpoint for reading below -40F. If above, then regenerate dryer <br />• Monthly - check and maintain operating conditions: pressure, flow, temperature within the design <br />of parameters of the dryer. <br />+ Six Months - recalibrate/chock span of moisture analyzer <br />• Six Mouths - replace pre -filter, after -filter, and separator elements if needed <br />• Annually - regonerate dyer, check regeneration cycle to ensure working properly <br />• 1000 Hours - change oil in blower <br />2000 Hour Intervals <br />• Post compression coalescing filter element replacement <br />• Compressor frame oil replacement (crankcase oil) <br />• Compressor frame oil replacement (cranlcase oil filter) <br />• Compressor oil strainer element cleaning <br />• Force feed lubricator box lube oil replacement <br />• Force feed lubricator filter replacement <br />• Compressor interstage coalescing filter element replacement <br />• Driver motor lubrication (grease bearings per manufacturers recommendations) <br />3000 Hour Intervals <br />• Post compression coalescing filter element replacement <br />4000 & 8000 Hour Intervals - Compressor Rebuild <br />• Post compression coalescing filter element replacement <br />• Compressor frame oil replacement (crankcase oil) <br />• Compressor frame oil replacement (crankcase oil filter) <br />• Compressor oil strainer element cleaning <br />• Force feed lubricator box lube oil replacement. - <br />i B225 Phdadelnhia Ccud Or:e;y; r5; �Xirgton Avc- WOO- Sveci dw <br />,Rancho Ccicaawgfj. GA 9! 7:30 at+.?e Pla-ts: C1Y'IOG01 O n;r ocn. AJh! 55960, <br />
The URL can be used to link to this page
Your browser does not support the video tag.