My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Item 28 - Measure M2 Funding Eligibility Renewal 2023-24
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2023
>
06/20/2023 Regular
>
Item 28 - Measure M2 Funding Eligibility Renewal 2023-24
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/12/2023 3:45:01 PM
Creation date
8/10/2023 8:24:12 AM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Clerk of the Council
Item #
28
Date
6/20/2023
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
91
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br />Urban Standards - Zone Requirements, cont'd <br />(a) Permitted building types and <br />minimum and maximum height <br />Table DT-1, entitled Building Types and Mimi mum <br />and Maximum Height identifies the approved <br />building types and the minimum and maximum <br />height that is permitted for each building type <br />within the DT zone subject to compliance with <br />all applicable standards, including Table DT-3 <br />entitled Building Height. <br />Table DT-1. Building Types and Minimum and <br />Maximum Height. <br />Build in g Types Min Stories Max Stories <br />Flex Block 2 10 <br />Lined Block 2 5 <br />Stacked Dwellings <br />2 <br />6 <br />Hybrid Court <br />not allowed <br />not allowed <br />Courtyard Housing <br />2 <br />5 <br />Live -Work <br />2 <br />3 <br />Rowhouse <br />not allowed <br />not allowed <br />Tuck -Under Housing <br />2 <br />3 <br />Bungalow Court <br />not allowed <br />not allowed <br />Duplex/Triplex/Quad- <br />plex <br />not allowed <br />not allowed <br />House <br />not allowed <br />not allowed <br />((1)Driveway Standards. Table DT-5 identifies the <br />minimum and maximum width of driveways and <br />permitted parking on driveways. <br />Table DT-5 Driveway Standards <br />1-way 8' 12' <br />2-way 20' 25' <br />Parking not permitted not permitted <br />(2) Off-street parking standards <br />a. Table DT-6 identifies the minimum off-street <br />parking spaces that shall be provided. All frac- <br />tions shall be rounded up to the next whole num- <br />ber. <br />Table DT-6. Off -Street Parking Standards <br />Residential [b] 2 / unit min 0.15 / unit guest <br />only <br />Live -Work 2 / unit in - - <br />Non -Residential 1 / 400 sq ft - yes <br />[a] May be satisfied through In -Lieu Fee and Park - <br />Once Program for Downtown District, if estab <br />lished. <br />[b] Permanent Special Need Housing including <br />senior housing, will be parked at 1 space per unit <br />minimum. <br />b. The parking requirements found in Table DT-6 <br />shall apply only to new buildings, additional <br />building area on existing buildings or con- <br />version of existing building area to a new use. <br />Conversion of building area of an historically <br />designated building to a new use, where the <br />building envelope is not increased in size shall <br />have no parking requirement until such time as <br />the City determines that 95 percent capacity on <br />the five existing City controlled parking struc- <br />tures in the downtown has been reached. <br />(b) Building Setbacks. <br />IF see encro ents <br />Id <br />le—mo <br />I <br />iF <br />I <br />i <br />I <br />o•. <br />II <br />T� <br />see encroachmen <br />Ie� <br />�¢ <br />— 1 I�I <br />_. �. _.J <br />treet Side <br />Table DT-2 identifies the minimum setbacks <br />required and, where noted, maximum setbacks <br />permitted. The setbacks shall apply to all stories <br />of a building. <br />Table DT-2. Building Setback Standards <br />(1 a) <br />Front yard <br />0' [a] <br />0' <br />(1 b) <br />Street Side <br />0'[a] <br />10, <br />(1 c) <br />Side yard <br />0' <br />No requirement <br />(1 d) <br />Rear yard <br />15' <br />No requirement <br />(1 e) <br />Alley yard <br />3' <br />No requirement <br />[a] In situations where the existing sidewalk is 10 <br />feet or less in width, at the discretion of the City <br />of Santa Ana, a setback greater than identified <br />in the above table may be required to effectively <br />result in a 10 foot wide sidewalk. <br />. Parking Permitted <br />c. Vehicular access to the off-street parking is per- <br />mitted only from an alley or side street when <br />present. Vehicular access to the off-street park- <br />ing may be taken from primary street only when <br />an alley or side street is not present. <br />d. Parking Setback Standards - Table DT-7, entitled <br />Parking Setback Standards identifies the mini- <br />mum setback standards for the off-street parking. <br />Table DT-7. Parking Setback Standards <br />Setback <br />(2a) Front yard <br />Above Grade <br />min 40% lot <br />depth <br />Subterranean <br />0' min <br />(2b) Street side <br />10' min <br />0' min <br />(2c) Side yard <br />0' min <br />0' min <br />(2d) Rear yard <br />10' min <br />3' min <br />(2e) Alley yard <br />T min <br />3' min <br />(c) Building Height and Frontage Require- <br />ments. <br />ri <br />R.O.W. �: roper y ine <br />1 Setback Line <br />Frontage <br />height and <br />other require- <br />ment. per <br />Section 4.2 <br />2i__"_"_" <br />if parcel has side <br />street frontage <br />(1) Building Height Table DT-3. Building Height <br />Table DT-3 entitled <br />Building Height <br />identifies the <br />maximum building <br />height permitted <br />based upon the lot <br />width and as per- <br />mitted b individual <br />'6 <br />Lot Width Max. <br />< 50 ft <br />3 stories <br />51 to 125ft <br />4 stories <br />125 to 1 75 ft <br />6 stories <br />175 ft <br />10 stories [1] <br />y building Type [1] 100 ft setback from all R.O.W. <br />required for stories 7-10. <br />(2)The ground floor Table DT-4. Frontage Types <br />fronting a street <br />or other right-of- <br />way (not including <br />alleys) shall comply <br />with the frontage <br />requirements per <br />Section 41-2039 and <br />per the Table DT-4, <br />entitled Frontage <br />Requirements. <br />Allowable l"MrR.QW �. Property Line <br />Encroachment per Setback Line <br />table below <br />2c 2c 2c <br />2a,b -! 2a,b : F 2b <br />(1) Outdoor dining - Such encroachments per <br />approval of PBA and PWA Directors, separate <br />permit and agreement. <br />(2) Encroachments. Awnings, Signage, Balconies, <br />Bay windows and Frontage Types may encroach <br />into the required setback subject to the standards <br />indentified in Table DT-8, entitled Encroachments. <br />Table DT-8 Encroachments <br />(2a) <br />except awnings, and gal- <br />min 8' <br />max 18" <br />lery, and arcade frontage <br />clear <br />types <br />(2b) <br />except awnings, and gal- <br />min 12' <br />max 24" <br />lery, and arcade frontage <br />clear <br />types <br />(2c) <br />awnings, and gallery, and <br />min <br />within 2' <br />arcade frontage types <br />10'clear <br />of curb <br />Side yard <br />N/A <br />0' <br />Rear yard <br />to eave [1] <br />5' <br />Alley yard <br />to eave [1] <br />3' <br />[1] Eave allowed to 3' of property line. <br />TRANSIT ZONING CODE 3:4 <br />SPECIFIC DEVELOPMENT 84 <br />City of Santa Ana, California <br />
The URL can be used to link to this page
Your browser does not support the video tag.