Laserfiche WebLink
HOT/COLD -A I' <br />HOSE BIB <br />s <br />(2) SELF CL( <br />15x <br />AUTO <br />OPENING I <br />PER CBC 71 <br />CHUTE MASTER <br />CONTROL <br />A-500 <br />ODOR COMPACTORS <br />CONTROL \ 6"W x 12"H <br />CURB (TYP.) <br />W, <br />CY SPARE <br />3CY SPAREF <br />PARE <br />3CY WASTE <br />✓ASTE <br />WASTE <br />CLING <br />COMPACTOR <br />OMPACTO <br />COMPACTOACTOR <br />CONTAINER <br />ONTAINER <br />CONTAINERAINER <br />3CY SPARE <br />RECYCLING <br />COMPACTOR <br />CONTAINER <br />T-0" EXIT <br />DOOR <br />ELECTRIC I <br />PALLET <br />JACK <br />STACKED POWER <br />PACK(2) <br />DISCONNECT <br />120V 15A SERVICE <br />OUTLET. (TYP) <br />F <br />I <br />6'-0" ROLL -UP DOOR <br />1 I <br />I <br />AIR COMPRESSOR <br />3CY <br />RECYCLING <br />COMPACTOI <br />CONTAINER <br />BUILDING A TRASH COLLECTION ROOM CORE 2 <br />UPPER VESITBULE LEVELS 02-07 <br />ICONSULTANT : <br />AMERICAN TRASH MANAGEMENT <br />AMERICAN PM415.292.5400 RFOR IAI946080 <br />92.5410 <br />TRASH MANAGEMENT S'BROW @TRASHMANAGE.COM <br />2'-2%" FROM <br />CENTER OF <br />CHUTE TO <br />ELEVATOR <br />18x18 SH AUTOMATIC <br />OPENING ELECTRICALLY <br />INTERLOCKED <br />THRU-WALL INTAKE <br />DOOR SEE NOTE 18 <br />3'-0" EXIT <br />DOOR <br />7F <br />A -A <br />LAiv <br />CENTRAL POINTE <br />SANTA ANA, CA # 2019-0129 <br />30"0 CHUTE <br />CHUTE DISCHARGE— \ <br />DOOR, SEE NOTE 14 <br />APOLLO MODEL A500 <br />COMPACTOR, (2) TOTAL <br />3CY NARROW <br />TOWABLE <br />CONTAINER <br />Lc) <br />(2) 30" 0 GAI <br />2'- 8 <br />W <br />FRONT VIEW <br />2A V/8" <br />SECTION A -A <br />SECTION B-B <br />SIDE VIEW <br />/ V -U <br />TOP VIEW <br />18x18 SH AUTOMATIC <br />/ OPENING ELECTRICALLY <br />/ INTERLOCKED <br />THRU-WALL INTAKE <br />DOOR SEE NOTE 18 <br />M LEVEL 1 <br />FROM <br />E OF <br />-E TO <br />kLL <br />-OMPACTOR FRONT <br />BIN NOT SHOWN <br />-ARITY. (TYP) <br />OM LEVEL 1 <br />N <br />i <br />3'-1" <br />REAR VIEW <br />3CY NARROW CONTAINER DETAILS <br />SCHEMATIC DESIGN <br />JULY 20TH, 2020 <br />0 2 4 8 <br />SHEET NOTES: <br />RESIDENTIAL TRASH TERMINATION ROOM <br />1. TRASH COLLECTION ROOM IS PART OF 2HR FIRE -RATED TRASH CHUTE <br />SHAFT - RESTRICTED ACCESS. <br />2. FLOOR SHALL BE FINISHED WITH WATERPROOF DECK COATING. FLOOR <br />TO HAVE MINIMAL SLOPE AND FLOOR DRAIN. FLOOR LEVEL UNDER <br />COMPACTOR. <br />3. WALLS SHALL BE FINISHED WITH WASHABLE WATERPROOF SURFACE <br />SUCH AS FRP OR HIGH -GLOSS ENAMEL PAINT, 8'-0" AFF. <br />4. INSTALL WALL PROTECTION: 12"Hx6"W CONCRETE CURB AT BASE OF ALL <br />NON -CONCRETE WALLS. DO NOT INSTALL THE CURB AROUND THE <br />COMPACTORS/BISORTER OR POWER PACKS. INSTALL STEEL PLATE WITH <br />DIAMOND TREAD BACKING ALONG WALL WHERE INDICATED FOR WALL <br />PROTECTION. <br />5. 6'-0" ROLL UP DOOR AND 3FT EXIT DOOR. <br />6. ROOM SHALL BE MECHANICALLY VENTILATED WITH (1) CFM/FT PER 2016 <br />CBC. <br />7. (2) 30" O GRAVITY CHUTE WITH COMPACTORS FOR WASTE & RECYCLING. <br />PROVIDE 3CY NARROW FL COMPACTOR CONTAINERS FOR WASTE & 3CY <br />NARROW FL COMPACTOR CONTAINER FOR RECYCLING. CHUTES SHALL <br />TERMINATE AT 5'-9" AFF. <br />8. PP: COMPACTOR POWER PACKS SHALL BE STACKED & FLOOR -MOUNTED. <br />(2) 5HP 3-PHASE, 208/230/460V. 30A DISCONNECTS60" AFF. <br />9. MCP: CHUTE MASTER CONTROL PANEL SHALL BE WALL -MOUNTED 60" AFF. <br />MUST ALLOW LOCK DOWN OF CHUTE INTAKES FOR EXCHANGING <br />CONTAINERS AND WASHING CHUTES. REQUIRES 120V 15A DEDICATED <br />SERVICE. <br />10. AC: 2HP CHUTE AIR COMPRESSOR SHALL BE FLOOR -MOUNTED. <br />REQUIRES 120V 15A SERVICE OUTLETS. <br />11. OC: ODOR CONTROL UNIT SHALL BE WALL -MOUNTED 60" AFF. REQUIRES <br />120V 15A SERVICE OUTLETS. <br />12. HB: HOT AND COLD HOSE BIB SHALL BE WALL -MOUNTED 60" AFF. <br />13. PROVIDE ELECTRIC PALLET TRUCK FOR TRANSFERRING CONTAINERS. <br />40001b CAPACITY; TURNING RADIUS: 45.5". REQUIRES 120V 15A SERVICE <br />OUTLETS. <br />14. CHUTE DISCHARGE DOOR: TYPE -A, HORIZONTALLY INSULATED <br />SLIDING -STEEL DOOR, HELD OPEN BY 165' F FUSIBLE LINK. <br />15. 5HP 3PHASE, 208/230/460V FOR THE POWER PACKS REQUIRED. <br />CHUTE INTAKE VESTIBULES: <br />16. CHUTE INTAKE VESTIBULES SHALL BE 1 HR FIRE -RATED WITH 1 HR <br />FIRE -RATED DOOR; 5-0" MIN REQUIRED PER ADA STANDARDS - <br />RESIDENTIAL ACCESS. PROVIDE (2) SELF CLOSING, 15x18 BOTTOM <br />HINGED, ELECTRICALLY INTERLOCKED, AUTOMATIC OPENING INTAKE <br />DOORS TO DISPOSE TRASH AND RECYCLING INTO COMPACTORS PER <br />CBC 713.13.1. POWER TO INTAKE DOORS SUPPLIED BY MCP. SEE DETAIL <br />1 T2.0. <br />17. CHUTE SHAFT SHALL NOT BE ERECTED UNTIL CHUTE HAS BEEN <br />INSTALLED. FOR SOUND PROOFING PURPOSES, DOUBLE STUD -WALLS <br />ARE REQUIRED ADJACENT TO OCCUPIED SPACES. INTERIOR OF SHAFT <br />SHALL BE TAPED TO PREVENT ODOROUS AIR LEAKING INTO OCCUPIED <br />SPACES. <br />18. PROVIDE 18X18 SIDE HINGED, AUTOMATIC OPENING, ELECTRICALLY <br />INTERLOCKED THRU-WALL INTAKE DOORS THAT DISPOSE INTO <br />CONTAINERS PER CBC 713.13.1. SEE DETAILS 2/T2.0. <br />19. PROVIDE ROUND FLOOR OPENINGS AT CONCRETE FLOORS AND <br />SQUARED FLOOR OPENINGS AT WOOD -FRAME CONSTRUCTION. INSTALL <br />FLOOR SUPPORT FRAME AT EACH FLOOR PENETRATION TO SECURE <br />CHUTE. SEE DETAIL 9/T2.0 FOR ANCHORING AND MASON BRA -RED SOUND <br />ISOLATION PAD ASSEMBLY.POUR RINGS WILL VARY BASED ON THICKNESS <br />OF FLOOR SLAB AND SHALL BE PROVIDED BY MANUFACTURER. <br />GENERAL NOTES: <br />1. ANY DESIGNS OR DESIGN SOLUTIONS PRESENTED IN THIS DRAWING OR <br />SPECIFICATION, WHICH ARE DIRECT OR IMPLIED, INCLUDING NARRATIVES, <br />DRAWINGS, OR DIAGRAMS, ARE HEREBY CLARIFIED AS EXAMPLES AND <br />SHALL NOT BE CONSIDERED COMPLETE DESIGNS OR DESIGNS SUITABLE <br />FOR CONSTRUCTION. <br />2. OMISSIONS FROM DRAWINGS OR SPECIFICATIONS, OR THE INACCURATE <br />DESCRIPTION OF DETAILS OF WORK, WHICH ARE MANIFESTLY <br />NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND <br />SPECIFICATIONS, OR WHICH ARE CUSTOMARILY PERFORMED, SHALL NOT <br />RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR <br />INACCURATELY DESCRIBED DETAILS OF THE WORK. WORK SHALL BE <br />PERFORMED AS IF FULLY AND CORRECTLY SET FORTH AND DESCRIBED IN <br />THE DRAWINGS AND SPECIFICATIONS. <br />3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND CONDITIONS <br />PRIOR TO START OF CONSTRUCTION. THE ARCHITECT SHALL BE NOTIFIED <br />IMMEDIATELY OF ALL EXISTING FIELD CONDITIONS AND ANY <br />DISCREPANCIES OR INCONSISTENCIES. <br />DESIGN ISSUES: <br />1. MOVED WALL ATTACHED TO INTAKE DOOR TOWARDS 3FT EXIT DOOR BY <br />638" IN ORDER TO MAKE ROOM FOR CHUTE FOOTINGS <br />TRASH COLLECTION ROOM CORE 2 <br />BUILDING A <br />T—1 ol <br />