Laserfiche WebLink
REVISIONS <br />DESCRIPTION <br />PARTIAL SITE ELECTRICAL PLAN 1/2" = 1'-0" <br />REFERENCES THESUPEDRVISION <br />OF: <br />BENCHMARK NO.: XX—XXX—XX ELEV.: NNN.NN' NAVDYY I I ISENIOR LANDSCAPE ARCHITECT <br />DATE <br />10/2021 <br />JAMES BRECK DESIGNED: ME DRAWN: AT CHECKED: ML <br />REVIEWED FOR ` <br />CONSTRUCTABILITY `// J���jy <br />AND RECOMMENDED <br />FOR CONSTRUCTION: <br />XX/YYYY <br />.IASON GARRIFI PRINCIPAL CIVII FNr,INFFR RCF NO.: 67968 <br />GENERAL NOTES <br />1. CONTRACTOR SHALL WALK SITE AND FIELD VERIFY ALL <br />REQUIREMENTS FOR ROUTING OF CONDUITS PRIOR TO BID. <br />2. CONTRACTOR SHALL EXERCISE CAUTION IN EXCAVATING AND <br />TRENCHING ON THIS SITE TO AVOID EXISTING DUCTS, PIPING, <br />CONDUITS, ETC. AND SHALL PREVENT HAZARD TO <br />PERSONNEL AND/OR DAMAGE TO EXISTING UNDERGROUND <br />UTILITIES OR STRUCTURES. THESE DOCUMENTS ARE NOT <br />RESPONSIBLE FOR THE LOCATION OF UNDERGROUND UTILITIES <br />OR STRUCTURES WHETHER OR NOT SHOWN, DETAILED OR <br />INSTALLED BY THIS OR ANY OTHER CONTRACTS. THE <br />CONTRACTOR SHALL IMMEDIATELY NOTIFY THE OWNER IF <br />UNFORESEEN CONDITIONS ARE DISCOVERED. THESE DRAWINGS <br />AND SPECIFICATIONS DO NOT INCLUDE NECESSARY <br />COMPONENTS FOR CONSTRUCTION SAFETY. <br />3. USE 3/4" CONDUIT (MINIMUM) AND #10 CONDUCTORS <br />(MINIMUM) FOR ALL SITE WIRING WORK. <br />4. REFER TO CEC TABLE 300-5 FOR MINIMUM CONDUIT BURIAL <br />5. ALL WORK SHALL BE VERIFIED AT MANDATORY PRE —BID JOB <br />WALK. <br />PLAN NOTES o <br />1. EXISTING IRRIGATION CONTROLLER TO BE DISCONNECTED AND <br />REMOVED. REMOVE BRANCH CIRCUIT WIRING BACK TO <br />SOURCE. <br />2. NEW PEDESTAL IRRIGATION CONTROLLER. REFER TO <br />LANDSCAPE DRAWINGS FOR SPECIFICATION. <br />3. PROVIDE 3/4" — 2#12 & 1#12 GROUND FROM PANEL BOARD <br />TO NEW IRRIGATION CONTROLLER. CONDUIT SHALL BE ROUTED <br />DOWN WALL FROM PANEL TO EXISTING CORE THRU WALL, <br />THRU WALL AND DOWN TO PLANTER AREA. CONTINUE <br />UNDERGROUND TO NEW IRRIGATION CONTROLLER AS SHOWN. <br />CONNECT TO EXISTING SPARE CIRCUIT REMAINING AFTER <br />DEMOLITION OF EXISTING IRRIGATION CONTROLLER. <br />Underground Service Alert <br />� of Southern California_ <br />TWO WORKING DAYS <br />BEFORE YOU DIG <br />Know what's below. <br />C Cllbefore you dig. ww.olgAlert.orq <br />NOTICE TO CONTRACTOR <br />PURSUANT TO ASSEMBLY BILL 4216 NO EXCAVATON PERMIT <br />IS VALID UNLESS THE CONTRACTOR CONTACTS AND OBTAINS <br />A DIG ALERT TICKET NUMBER. CALL 811 AT LEAST TWO <br />WORKING DAYS PRIOR TO COMMENCING EXCAVATION. <br />Robert J. Hatch, P.E. <br />tyQFE55/ <br />LE- e <br />LENWC 1) j16 <br />E INC INf E WNC I MC <br />'PT P <br />EXP. TWI123 <br />PARTIAL SITE ELECTRICAL PLAN I <br />CABRILLO PARK IRRIGATION RENOVATION <br />CABRILLO PARK — CORNER OF CABRILLO PARK DR. & FRUIT ST. <br />PUBLIC WORKS AGENCY <br />CITY OF SANTA ANA SHEET 12 OF 12 <br />