Laserfiche WebLink
ON-STE <br />Dave Valerio, CWI, NACE <br />Senior Inspector -Inspector <br />Senior Inspector, CWI inspector IDE-Poseidon Resources -Provides site welding <br />inspection of stainless -steel SMO 254 specialty fittings associated with emergency repair <br />of 6"-14" diameter piping; duties included welder qualification testing, welding inspection <br />documentation of each weld segment calculating travel speed and heat input for strict <br />conformance with WPS requirements. <br />• Claude "Bud" Lewis Carlsbad Desalination Plant <br />Senior Inspector, CWI inspector OTAY MWD-As Needed Inspection Services -As Senior <br />Inspector provides in plant fabrication welding inspection of Large Diameter pipe, <br />specialty fittings and related NACE coating inspection for the following Projects; duties <br />included welding inspection, hydro testing, and welder qualification testing: <br />• Otay Crossings Commerce Park Tract 5405-1 <br />• Western Waterworks-Otay Ranch -Village 3, Heritage Road <br />Fabrication Inspector - CWI & NACE I Coating Specialist (Los Angeles World Airport) <br />Performs fabrication Quality Assurance services of large diameter pipe, mechanical <br />equipment, structural steel, stairs, railings, ductile iron pipe, concrete reinforced pipe, <br />valves, roof joists, transformers, switchgear, HVAC, VFD, PLC, electric circuits, mechanical <br />systems, hydraulics and cast iron floor hatches, glass supported railing, modular air <br />handling units, fixed walk ways. <br />• The Southside Runway Improvements Project <br />QC Supervisor NOV AMERON INTERNATIONAL WATER TRANS GROUP WIND TOWER <br />DIV. FONTANA, CA <br />Duties included the destructive and non-destructive testing of materials used in the <br />manufacture of large diameter cement, tape and epoxy lined, and coated steel pipe up to <br />196" in diameter. Examples include, but are not limited to Visual weld inspection, <br />magnetic particle, dye penetrant, hardness, tensile and bend testing of welds and steel. <br />Compression, moisture absorption, and batch moisture content testing of cement linings <br />and coatings. Performed Physical testing of cold applied plastic tape and epoxy coatings, <br />duties included thickness verification and adhesion testing for various tape and epoxy <br />coatings; aided in the development and implementation of the ISO 9002 Quality <br />Management System. <br />Meet with the Project Representative or Client to review the requirements of the contract <br />specifications and any codes or standards that may be applicable. Supervise the QC <br />Technicians on the shop floor and help in training and advising them of methods and <br />techniques. Review the specifications and help in establishing hold points and third party <br />witness points. Help in establish the extent and methods of NDE. <br />