My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Item 07 - ORDINANCE AMENDING CHAPTERS 8 AND 14 OF SAMC
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2022
>
12/20/2022 Special & Regular
>
Item 07 - ORDINANCE AMENDING CHAPTERS 8 AND 14 OF SAMC
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/22/2023 12:42:55 PM
Creation date
8/22/2023 12:42:47 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Clerk of the Council
Item #
7
Date
12/20/2022
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Ordinance No. NS-XXX <br />Page 27 of 30 <br /> <br /> Exceptions: <br /> <br />1. Brass or bronze valves on sprinkler risers mounted to the exterior of the <br />building may be left unpainted. <br />2. Where OS&Y valves on the detector check assembly are the only control <br />valves, at least one OS&Y valve shall be painted red. <br /> <br />(2) Section 6.2.9 is hereby amended as follows: <br /> <br />All connections to private fire service mains for fire protection systems shall be <br />arranged in accordance with one of the following so that they can be isolated: <br /> <br />(1) A post indicator valve installed not less than 40 ft (12 m) from the building <br /> <br />(a) For buildings less than 40 ft (12 m) in height, a post indicator <br />valve shall be permitted to be installed closer than 40 ft (12 m) but at <br />least as far from the building as the height of the wall facing the post <br />indicator valve. <br /> <br />(2) A wall post indicator valve <br /> <br />(3) An indicating valve in a pit, installed in accordance with Section 6.4 <br /> <br />(4) A backflow preventer with at least one indicating valve not less than 40 ft <br />(12 m) from the building <br /> <br />(a) For buildings less than 40 ft (12 m) in height, a backflow preventer <br />with at least one indicating valve shall be permitted to be installed <br />closer than 40 ft (12 m) but at least as far from the building as the <br />height of the wall facing the backflow preventer. <br /> <br />(5) Control valves installed in a fire-rated room accessible from the exterior <br /> <br />(6) Control valves in a fire-rated stair enclosure accessible from the exterior <br /> <br />(3) Section 10.1.5 is hereby added as follows: <br /> <br />10.1.5 All ferrous pipe and joints shall be polyethylene encased per AWWA C150, <br />Method A, B, or C. All fittings shall be protected with a loose 8-mil polyethylene <br />tube or sheet. The ends of the tube or sheet shall extend past the joint by a <br />minimum of 12 inches and be sealed with 2-inch-wide tape approved for <br />underground use. Galvanizing does not meet the requirements of this section. <br /> <br /> Exception: 304 or 316 Stainless Steel pipe and fittings <br />
The URL can be used to link to this page
Your browser does not support the video tag.