Laserfiche WebLink
would require adding another story to the building to meet the <br />ground floor commercial requirement and to still provide the <br />number of units that the applicant is entitled to under State law. <br />Maximum Height (Waiver) <br />The maximum height permitted in the CDR district of the TZC is <br />three stories. As proposed, the maximum height of the new <br />structure would be four stories (58-feet, nine -inches). However, <br />only the stairwell and elevator penthouse will be at the maximum <br />height, and the rest of the four-story structure would be 51-feet, <br />nine -inches in height. <br />The proposed fourth story is needed to make construction of the <br />residential development financially feasible. The gross site area <br />and existing site conditions severely restrict the applicant from <br />providing a site plan that could accommodate the proposed number <br />of units with a three story building type. With the current maximum <br />height restriction, the applicant could propose underground parking <br />to take advantage of the limited gross site area. However, this <br />would result in a project that is financially infeasible. Strict <br />adherence to the maximum height requirement would result in a <br />loss of four residential units, would physically preclude construction <br />of the project, and would preclude the construction of the affordable <br />unit to be dedicated to very -low income occupants. This would also <br />make the project infeasible and would not allow the applicant to <br />achieve the full 27.5-percent density bonus to which the applicant is <br />entitled under State law. <br />Building Size and Massing Standards — Maximum Ratio for each <br />Flex Block story (Waiver) <br />Pursuant to Section 41-2022 of the TZC, the residential building is <br />designed as Flex Block Building Type. The building type <br />establishes a maximum ratio for each flex block story/level. <br />Specifically, the second through fourth floor can only be 85-percent <br />of the ground floor volume/gross floor area. As designed, the <br />second through fourth floor cannot exceed 3,309 square feet. <br />The second through fourth floor of the proposed building exceed <br />the allowable ratio and are 97.9-percent of the ground floor's <br />volume. The second through fourth floor are proposed to be 3,811 <br />square feet, exceeding the maximum allowable by 502 square feet. <br />The proposed site has a smaller than average lot depth and lot <br />width, compared to most lots in the downtown area. Lots in the <br />downtown area range in lot depth and width but are on average 250 <br />feet by 250 feet. The subject site is approximately 100 feet by 125 <br />Resolution No. 2023-XX <br />Page 4 of 13 <br />