Laserfiche WebLink
feet. Without the increase in the allowable building size and <br />massing standards, the project would need to be redesigned, <br />resulting in several impacts to the feasibility of the site's <br />development. These impacts would include a loss parking spaces; <br />an incompatible design and unbalanced composition of massing <br />the project site; and a smaller building footprint that would reduce <br />the building's interior floor area and individual unit sizes and result <br />in a loss of units. <br />In order to provide the required building size and massing <br />standards, the developer would be required to construct an <br />additional level, resulting in a different type of construction (steel - <br />frame versus wood), or build underground parking, further <br />increasing development costs and making the project infeasible. <br />Open Space Standards (Waiver) <br />Pursuant to Section 41-2022 of the TZC, the residential building is <br />designed as Flex Block Building Type. This building type requires <br />common open space to be designed as a courtyard or in the front <br />as a forecourt, have it open to the sky, and to be equal to 15- <br />percent of the lot. Moreover, private open space is required to be <br />provided for each residential unit, no less than 50 square feet with a <br />minimum dimension of six feet in each direction. The total common <br />open space required is 1,875 square feet and the total private open <br />space required is 750 square feet. <br />As proposed, the project provides 433 square feet of common <br />interior space, provided in the form of lobby space (approximately <br />3.5-percent of lot). To the extent feasible, the lobby space is to be <br />furnished (e.g., coffee tables, chairs, lounge tables, etc.). The <br />project also provides 591 square feet of private open space, in the <br />form of private decks for nine units. The gross site area and <br />existing site conditions severely restrict the ability for the project to <br />accommodate any common open space, and restrict the ability to <br />provide the fully required private open space. Providing the <br />required common open space standard would lead to the <br />elimination of three or more units, which would affect the feasibility <br />to construct the project. In order to maintain the current proposed <br />unit count, the developer would be required to construct additional <br />floor levels or required to provide underground parking, which <br />would further increase development costs and make the project <br />financially infeasible. To help alleviate the common open space <br />deficiency, the project proposes an average of 40 square feet of <br />private open space per unit, through use of private balconies/decks. <br />Resolution No. 2023-XX <br />Page 5 of 13 <br />