Laserfiche WebLink
"Section 8224. CoollngWater. <br /> <br /> "Sec. 609 of s~ d Code is amended by adding a new sentence <br />at the end to read: 'Such water from these appliances, devices <br />or apparatus used in ~ny structure shall not be discharged or <br />drained into any street or alley.'" <br /> <br />"Section 8225. Vertical Wet Venting. <br /> <br /> "Sec. 614 of said Code is amended by substituting for the en- <br />tire section a new section to read: ,Vertical Wet Venting shall <br />not be permitted.'" <br /> <br />"Section 8226. Combination Waste and Vent System. <br /> <br /> "Sec. 615 (e) of said Code is amended to read: 'Unless spec- <br />ifically required or permitted by the Administrative Authority <br />no vertical waste pipe shall be used in any such system except <br />the tail piece or connection between the outlet of a plumbing <br />fixture and t~e trap therefor. Such tail pieces or connections <br />shall in no case exceed two (2') feet.'" <br /> <br />"Section 8227. Traps Required. <br /> <br /> "Sec. 701 (d) <br />distance between <br />outlet shall not <br /> <br />of smd Code is amended to read: 'The vertical <br />a fixture outlet ~ d the center of the waste <br />exceed twelve (12") inches in length.'" <br /> <br />"Section 8228. Grease Interceptors. <br /> <br /> "Sec. 711 (a) of said Code is amended to read: 'An approved <br />type grease interceptor complying w~th the provisions of this <br />section shall be installed in the waste line leading from sinks, <br />drains, and other fixtures or equipment only when required by <br />the Director of Public Works, or by the Health Department, in <br />establishments where grease can be introduced into the drainage <br />system or sewage system in quantities that can effect line stop- <br />page or hinder sewage treatment. A grease interceptor is not re- <br />quired for individual dwelling units or for any private living <br />quarters.'" <br /> <br />"Section 8229. Grease Interceptor Plans. <br /> <br /> "Sec. 711 (b) of said Code is amended to read: ,Plans shall <br />be submitted to the Department having Jurisdiction and ~proval <br />obtained prior to the installation of any plumbing system or part <br />thereof designed to include a grease interceptor.'" <br /> <br />"Section 8230. Prohibited Joints and Connections. <br /> <br />"Sec. 806 (b) of said Code is amended to read: 'No fitting or <br />connection that offers abnormal obstruction to flow, sh~l be used.'" <br /> <br />"Section 8231. Size, Rise and Run of Vents and Vent Connectors. <br /> <br /> "Sec. 1318 (d) of said Code is mended to read: 'Metal vent <br />connectors shall be not less in diameter than the vent outlet of <br />the water heater. Vent connectors shall have a rise of no less <br />tha~ one fourth (~") inch per foot of length. The horizontal <br />projected length shall not exceed seventy-five (75%) per cent of <br />the vertical projected length of the vent and vent connector.," <br /> <br />"Section 8232. Independent Vent Required. <br /> "Requirement four (4) of Section 1320 of s~ d Code is amended <br />to read: 'Both the vent manifold and the vent connectors shall <br /> <br />-6- <br /> <br /> <br />