(c) Entrance doorways providing access to the premises <br />from the exterior shall be provided with exterior illumina- <br />tion suitably located. The illuminating source shall be <br />controlled by an interior switch conveniently located near <br />the doorway. <br />NOTE: The intent of the above is not to provide a light <br /> and switch at every door, but only to provide adequate <br /> illumination for normal egress and ingress at all <br /> doors. <br /> <br /> SECTION 35: That the Santa Ana Municipal Code is hereby <br />amended by repealing and re-enacting Section 8-826 thereof to read <br />as follows: <br /> <br />Sec. 8-826. <br /> <br /> Section <br />Edition , <br /> <br /> Wiring Methods. <br />230.44 of the National Electrical Code, <br />is hereby amended to read as follows: <br /> <br />1968 <br /> <br />230-44. Wiring Methods. <br /> Service-entrance conductors extending along the exterior <br /> or entering buildings or other structures shall be <br /> enclosed in rigid conduits, or, for circuits not ex- <br /> ceeding 600 volts, in wireways, auxiliary gutter, or <br /> as busways. <br /> <br /> SECTION 36: That the Santa Aha Municipal Code is hereby <br />amended by repealing and re-enacting Section 8-857 thereof to read <br />as follows: <br /> <br />Sec. 8-857. Deletion of Section 230-70(g) <br /> Section 230-70(g) of the National Electrical Code, <br />Edition, is hereby deleted. <br /> <br />1968 <br /> <br /> SECTION 37: That the Santa Ana Municipal Code is hereby <br />amended by repealing and re-enacting Section 8-879 thereof to read <br />as follows: <br /> <br />Sec. 8-879. Ratinq of Service Equipment. <br /> <br /> Section 230-71(a) of the National Electrical Code, 1968 <br />Edition, is hereby amended by amending Exception No. 1 <br />thereof to read as follows: <br /> EXCEPTION NO. 1. For single family residences having a <br />floor area of 1000 square feet or over, or an initial load <br />of 10 K.W. or more, computed in accordance with Section 220-4, <br />the service equipment shall have a rating of not less than <br />100 amperes, 230 volt, 3 wire. <br /> <br /> SECTION 38: That the Santa Ana Municipal Code is hereby <br />amended by amending Section 8-896 thereof to read as follows: <br /> <br />Sec. 8-896. Overcurrent Protection. <br /> Section 240-16 of the National Electrical Code, 1968 <br />Edition, is hereby amended to read as follows: <br /> 240-16. Location in Premises. <br /> Overcurrent devices shall be located where they will be: <br /> (a) readily accessible, except as provided in Section 230- <br /> 91 and 230-92 for service equipment and Section 364-11 for <br /> busways; <br /> (b) not exposed to physical damage; <br /> (c) not in the vicinity of easily ignitable materials; and <br /> (d) branch circuit protective devices shall be installed <br /> in and for each occupancy. <br /> <br />-18- <br /> <br /> <br />