My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
NS-1579
Clerk
>
Ordinances
>
1953 - 1999 (NS-001-NS-2415)
>
1981 (NS-1562 - NS-1614)
>
NS-1579
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2012 1:04:18 PM
Creation date
6/26/2003 10:08:06 AM
Metadata
Fields
Template:
City Clerk
Doc Type
Ordinance
Doc #
NS-1579
Date
4/20/1981
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
3
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ORDINANCE NO. NS- 1579 <br />PAGE TWO <br /> <br /> SECTION 3: That Section 8-828 of the Santa Ana Municipal <br />Code is hereby amended to read as follows: <br /> <br /> Sec. 8-828. Receptable Outlets Required (Section <br />210-52(f)) <br /> <br /> Section 210-52(f) of the National Electrical Code is to <br />read as follows: <br /> <br /> At least one (1) receptacle outlet shall be installed <br />in each basement, garage, and carport. Garages or carports <br />accessory to dwelling units shall be wired with a minimum of <br />one (1) lighting outlet per each two (2) auto stalls or <br />fractions thereof. <br /> <br /> EXCEPTION: In hotel, motel, and multiple occupancies, <br />garage and carport receptacles may be omitted. <br /> <br /> SECTION 4: That Section 8-829 of the Santa Aha Municipal <br />Code is hereby amended to read as follows: <br /> <br />Sec. 8-829. Lighting Outlets Required (Section 210-70(a)) <br /> <br /> The first paragraph of Section 210-70(a) of the National <br />Electrical Code is amended to read as follows: <br /> <br /> At least one (1) wall switch controlled lighting outlet <br />shall be installed in every habitable room; in bathrooms, <br />hallways, stairways, garages, and carports, and at outdoor <br />entrances. <br /> <br /> That Section 8-843 of the Santa Ana Municipal Code is <br />hereby amended to read as follows: <br /> <br />Sec. 8-843. Branch Circuits Required (Section 220-3) <br /> <br /> Section 220-3 of the National Electrical Code is amended <br />by adding three sentences to the introductory paragraph <br />thereof to read as follows: <br /> <br /> No convenience receptacle or appliance receptacle shall <br />be installed or operated on a general lighting branch circuit <br />at any time in any occupancy. A one-half hot and one-half <br />switched receptacle may be installed on a lighting branch <br />circuit when used as the lighting outlet required for habitable <br />rooms permitted in 210-70(a), Exception No. 1. There is a <br />maximum of twelve (12) convenience receptacle outlets or <br />twelve (12) lighting outlets to any one circuit. <br /> <br /> SECTION 5: That Section 8-1025 of the Santa Ana Municipal <br />Code is hereby amended to read as follows: <br /> <br />Sec. 8-1025. Branch-Circuit Sizing (Section 422-5) <br /> <br /> Section 422-5 of the National Electrical Code is amended <br />by adding a paragraph designated (c) to read as follows: <br /> <br /> (c) In every dwelling unit, fixed appliances such as <br />food grinders, dishwasher, washing machines, dryers, laundry <br />tray locations, built-in heaters, or any other fixed appliances <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.