Laserfiche WebLink
ORDINANCE NO. NS- 1598 <br />Page Five <br /> <br />constitute grounds for denial of the application by the <br />director, and such owners shall have no right of appeal from <br />such denial. <br /> <br /> (c) APPEAL. If an application is denied, other than <br />for the owners' failure to execute and file with the director <br />the agreement specified in subsection (b) of this section, <br />the director shall specify in writing the reason or reasons <br />why said application is denied. Within fifteen (15) days after <br />the director mails notice of the denial of the application, <br />any owner may appeal the director's denial to the uniform <br />code appeals board in the manner specified by subsection (d) <br />of Section 8-2004 of this article. Thereafter, said appeal <br />shall be governed by the provisions of subsection (d) of <br />Section 8-2004 of this article. <br /> <br />SECTION 4: That section 8-2005 of the Santa Aha Municipal <br />Code, is hereby amended to read as follows: <br /> <br />Sec. 8-2005. ANALYSIS AND DESIGN <br /> <br /> (a) GENERAL. Every structure within the scope of this <br />article shall be analyzed and constructed to resist minimum <br />total lateral seismic forces assumed to act nonconcurrently <br />in the direction of each of the main axes of the structure <br />in accordance with the following equation: <br /> <br />V = IKCSW <br /> <br />The value of "IKCS" need not exceed the values set forth in <br />Table B based on the appropriate priority rating. <br /> <br />TABLE B <br />HORIZONTAL FORCE FACTORS BASED <br /> ON RATING CLASSIFICATION <br /> <br />RATING <br />CLASSIFICATION IKCS <br /> <br />I 0.186 <br />II 0.133 <br />III & IV 0.100 <br /> <br /> (b) LATERAL FHRCES ON ELEMENTS OF STRUCTURES. Parts <br />or portions of structures shall be analyzed and designed for <br />lateral loads in accordance with Chapter 23 of the Uniform <br />Building Code but no less than the value from the following <br />equation: <br /> <br />F = IC SW <br /> P P P <br /> <br />For the provision of this subsection, the product of "IS" <br />need not exceed the values as set forth in Table C. <br /> <br /> EXCEPTION: Unreinforced masonry walls in buildings <br />not having a rating classification of I may be analyzed in <br />accordance with Section 8-2006. <br /> <br /> (c) ANCHORAGE AND INTERCONNECTION. Anchorage and <br />interconnection of all parts, portions and elements of the <br />structure shall be analyzed and designed for lateral forces <br />in accordance with the equation F IC SW as modified by <br />Table C. Minimum anchorage of masonry ~all~ to each floor <br />or roof shall resist a minimum force of two hundred (200) <br />pounds per lineal foot acting normal to the wall at the <br />level of the floor or roof. <br /> <br /> <br />