My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1927 (#803-839)
Clerk
>
Ordinances
>
1886 - 1952
>
1926-1930
>
1927 (#803-839)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2012 1:07:21 PM
Creation date
4/22/2003 2:31:51 PM
Metadata
Fields
Template:
Pre-Charter
Year
1927
Pre-Charter - Doc Type
Ordinances
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
99
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Section 23. <br /> <br />Out]ets per circuit in residences. <br /> <br />In arranging circuits for the lighting of residences, flats or apartments, no <br />~ircuit to which is connected a ceiling outlet located in a kitchen, dining room, front or <br />sitting room, shall have more than eight outlets connected thereto. No circuit supplying <br />any part of a residence, flat or apartment shall have more than ten outlets, nor more than <br />sixteen sockets connected thereto. No. 3 wire b~anch lighting circuit shall be installed. <br /> <br /> In arranging circuits in dwellings, flats, and apartments of all buildings, each <br />ceiling outlet shall be wired for not less than the number and size of lamps specified in the <br />following tables: <br /> <br />Room- No. of 4 Ow. lamps <br /> <br />Reception Hall 3 <br />Library 4 <br />Living Room 4 <br />Dining Room 4 <br />Den 5 <br />Breakfast Room 2 <br />Kitchen 2 <br />Bed Room 2 <br />Bath Room 2 <br />Hotel Bed Rooms 2 <br />Ail other rooms 1 <br /> <br />Section 24. <br /> <br /> No additional work shall be attached to any existing installation without ~btaining <br />)ermission from the City Electrician to do so. <br /> <br /> (a) Where alterations or additions are made in any installations the approval for <br />;he use of old material must be obtained from the City Electrician before it is used. <br /> <br /> (b) All hotels, factories, work-shops, school, detention buildings, assembly halls, <br />theaters and all otherrbuildings requiring fire escapes, which are occupied at night, shall <br />have all public halls, stairways, and passageways properly lighted and at the head and the foot <br />of each flight of stairm, and at the point of egress to each fire escape shall be kept burning <br /> red light at all times. <br /> <br /> Permission is given by this ordinance to install four circuits on each 2-wire service <br />ut each circuit must not exceed 880 watts. All lighting circuits unless otherwise specified <br />~ust be considered as 880 watts. <br /> <br />(c) All switches, cutouts, first installations fuses, complete mains and meter <br />loops, and all connections in wiring necessary for placing any meter must be installed by the <br />~ereon, firm or corporation to whom the permit for such installation is issued. <br /> <br /> All main line switches and sub-switches mu~t be kept within six (6) feet of floor; <br />round or working platform. <br /> <br /> All connectims must be soldered and taped, first with rubber and th~n friction tape. <br />.ll wires No. B and over running to switches, must be lugged. <br /> <br /> (d) Bell trans~mmers must be installed in separate metal cabinets or in cutout <br />cabinets. <br /> <br /> (e) Any building or structure (other than private residence) in the Fire District <br />Ihf the City of Santa Aha as now and hereafter fixed by ~dlnance of the City Council, when <br />ltered, repaired, remodeled or changed in any way to exdeed the value of Twelnty-five (25) <br />ollars, all wires which were previously installed in said building or structure and used for <br />e purpose of conducting electricity for heat, light, o~ power must be installed or reinstalle <br />n approved metal conduit, armored cable, or metal moulding and any building or structure <br />ltered, repaired or removed, that is not in the Fire District, must have building service <br />~hanged or installed to conform with the existing electrical ordinance. <br /> <br /> (f) Every system of wiring for light and motor installations shall be so installed <br />~s not to exceed 3% drop over all. <br /> <br /> For <br />?actor will be permitted. <br /> <br />calculating the voltage loss of feeders and sub-feeders the fol2owing demand <br /> <br /> Classification Demand Factor <br />Apartment Houses: ~o. 'Of Apartments. <br /> 1 to 8 100% <br /> 6 to 10 90 <br /> ll to 18 80 <br /> 16 to 26 70 <br /> 26 to 35 60 <br /> ab~ e 35 50 <br />Clothing ~fg. ~lants 90 <br />Department Stores 90 <br />Foundries V5 <br />Garages (Public) 75 <br />Hospitals 60 <br />Hotels 75 <br />~achine Shops ~5 <br />Mfg. Plan (G~neral) 75 <br />Office Buildings BO <br />Packing Houses 80 <br />Prlnt~ng Establishments ~0 <br />Tanneries 75 <br />Theaters and Schools 100 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.