Laserfiche WebLink
SOUTH COAST TECHNOLOGY CENTER <br />3100 Lake Center Drive, Santa Ana, California <br />SHEET INDEX: <br />T-1 Title Sheet <br />T-2 Notes <br />A-1.1 Overall Existing Site Plan <br />A-1.2 Overall Fire Access & Accessible Path of Travel Site Plan <br />A-1.3 Overall Trash Collection Site Plan <br />A-1.4 Building 1 - Enlarged Site Plan <br />A-1.5 Buildings 2 & 3 - Enlarged Site Plan <br />A-1.5A Building 3 Site Plan - 40' & 60' Yards <br />A-1.6 Overall WB-67 Truck Access -In Site Plan <br />A-1.7 Overall WB-67 Truck Access -Out Site Plan <br />A-1.8 Trash Enclosure Enlarge Plan & Details <br />Site Plan Review <br />3rd u b m itta I (Includes Bldg. 3 Slip Sheets) <br />VICINITY MAP: <br /># ,-Z'h-4 - ! <br />W <br />I -ar <br />Per anente...y <br />o <br />Deo <br />it _, �, .- � • . <br />profession <br />'Super King <br />Market 'Santa -Ana <br />hur Blvd . <br />-�- 0 0 , nve B <br />n�iwr Iy <br />him <br />_ it in <br />Cor Movate Park <br />is <br />1 w_ 1( 3 <br />Jr <br />_ <br />Tec_ D <br />�,�.- 1N .IeCo rfy,, ,t" See • <br />_- Csei non,. k <br />r ve W Sun Rol er A W $W1f10 e e Sunflovrer-A a W `• <br />° c» M• l■= i1, <br />g. Cas o .a /McC nn �4f 00 <br />a .i ■ d , <br />0 <br />C-2.0 <br />Existing <br />Conditions <br />Key Plan <br />C-2.1 <br />Existing <br />Conditions <br />Plan <br />C-2.2 <br />Existing <br />Conditions <br />Plan <br />C-2.3 <br />Existing <br />Conditions <br />Plan <br />C-2.4 <br />Existing <br />Conditions <br />Plan <br />C-2.5 <br />Existing <br />Conditions <br />Plan <br />C-2.6 <br />Existing <br />Conditions <br />Plan <br />C-2.7 <br />Existing <br />Major Street Cross -Section <br />C-3.1 <br />Grading Plan <br />C-3.2 <br />Grading Plan <br />C-3.3 <br />Grading Plan <br />C-3.4 <br />Offsite Improvement Plan <br />C-3.5 <br />Offsite Improvement Plan <br />C-3.6 <br />Offsite Improvement Plan <br />C-4.1 <br />Utility Plan <br />C-4.2 <br />Utility Plan <br />C-4.3 <br />Utility Plan <br />C-5.1 Fire Access and Hydrant Plan <br />C-6.1 BMP Exhibit <br />L-1 Overall Landscape Concept Plan <br />L-2 Building 1 Landscape Concept Plan <br />L-3 Building 2 &3 Landscape Concept Plan <br />L-4 Park Plaza & Corner Landscape Concept Enlargement Plan <br />L-5 Building Entry & Patio Landscape Concept Enlargement Plan <br />A-2.1 Building 1 - 1st Floor Plan <br />A-2.2 Building 2 - 1 st Floor Plan <br />A-2.3 Building 3 - 1 st Floor Plan <br />A-3.1 <br />Renderings Building 2 <br />A-3.2 <br />Renderings Building 2 <br />A-3.3 <br />Renderings Building 1 <br />A-3.4 <br />Renderings Building 2 & 3 <br />A-3.5 <br />Renderings Park <br />A-4.1 <br />Building 1 Exterior Elevations <br />A-4.2 <br />Building 1 Exterior Elevations & Section <br />A-4.3 <br />Building 2 Exterior Elevations <br />A-4.4 <br />Building 2 Exterior Elevations & Section <br />A-4.5 <br />Building 3 Exterior Elevations <br />A-4.6 <br />Building 3 Exterior Elevations & Section <br />OWNER/ C.J. SEGERSTROM & SONS <br />APPLICANT: <br />a Californa general partnership <br />3315 FAIRFVIEW ROAD <br />COSTA MESA, CA 92626 <br />CONTACT: JEFF REESE - E: reesej@southcoastplaza.com <br />C: (714) 949.438.3250 <br />LANDSCAPE <br />ARCHITECT: D P - Conceptual Design & Planning <br />a Californa general partnership <br />3195-C AIRPORT LOOP DRIVE I STUDIO ONE <br />COSTA MESA, CA 92626 <br />CONTACT: ERIK PETERSON - E: epeterson@cdpcinc.com <br />P: (949) 399.0870 <br />SITE TABULATION: <br />OVERALL TABULATIONS BUILDINGS 1 - 3 <br />ARCHITECT: DRA ARCHITECTS <br />32 EXECUTIVE PARK, SUITE 100 IRVINE, CA 92614 <br />CONTACT: CARRIE HOSHINO - E: CHOSHINO@DRA-ARCHITECTS.COM <br />C: 949.280.8307 <br />CIVIL ENGINEER: INCLEDON CONSULTING GROUP <br />1570 CORPORATE DRIVE, SUITE A, COSTA MESA, CA 92626 <br />CONTACT: KEVIN HADLEY - E: khadley@icgcivil.com <br />C: 909.915.4976 <br />TYPE OF BUILDING CONSTRUCTION TYPE III-B <br />AUTOMATIC FIRE SPRINKLERS YES <br />ZONING DISTRICT SD - SPECIFIC DEVELOPMENT <br />LAND USE LAKE CENTER DEV <br />FAR ALLOWED 0.72 <br />APN(S) 414-261-01, 414-272-09, 414-272-10 <br />BUILDING OCCUPANCY S-1, F-1 AND B <br />----------------------- ------------------------------------------------------------------------------------------------------------------------------------------------------------------- <br />WALL CONSTRUCTION Concrete Tilt -Up Walls <br />------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ <br />ROOF CONSTRUCTION Parapet, 4-Ply "Flat -Roof" <br />FIRE SPRINKLERED BUILDINGS YES <br />BUILDING NO. <br />BLDG. 1A <br />BLDG. 1 B <br />BLDG.1 <br />TOTAL <br />BLDG. 2A <br />BLDG. 2B <br />BLDG.2 <br />TOTAL <br />BLDG.3 <br />TOTAL <br />TOTALS <br />SITE AREA AC <br />5.58 <br />5.76 <br />4.49 <br />15.8 AC <br />SITE AREA SF <br />243,212 <br />250,690 <br />195,408 <br />689,310 SF <br />EXISTING BUILDING SF TO BE DEMOLISHED <br />0 <br />117,564 <br />60,462 <br />178,026 SF <br />TOTAL PROPOSED BUILDING AREA <br />56,615 <br />56,115 <br />112,230 <br />60,823 <br />60,823 <br />121,645 <br />79,369 <br />313,244 SF <br />YARD AREA <br />4-UNLIMITED <br />4-UNLIMITED <br />4-UNLIMITED <br />COVERAGE <br />44.1 % <br />44.5% <br />37.0% <br />42.3% <br />FAR -CITY WHICH EXCLUDES MEZZANINES <br />44.1 % <br />44.5% <br />37.0% <br />42.3% <br />FAR - INCLUDES MEZZANINES <br />46.1% <br />48.5% <br />40.6% <br />45.4% <br />TOTAL PARKING REQUIRED <br />164 <br />177 153 <br />494 STALLS <br />TOTAL PARKING PROVIDED <br />164 <br />178 155 <br />497 STALLS <br />PARKING RATIO PROVIDED <br />1.46 <br />1.46 1.95 1.59 RATIO <br />OUTDOOR COVERED PATIO AREA <br />1,210 <br />1 <br />1 707 <br />895 <br />29812 <br />SF <br />9,915 9,915 9,915 <br />1ST FLOOR <br />53,615 <br />53,615 <br />107,230 <br />55,823 <br />55,823 <br />111,645 <br />72,369 <br />2915244 SF <br />Office <br />2,500 <br />2,500 <br />5,000 <br />5,000 <br />5,000 <br />10,000 <br />7,000 <br />22,000 SF <br />Manufacturing <br />23,615 <br />23,615 <br />47,230 <br />23,323 <br />23,323 <br />46,645 <br />60,369 <br />1545244 SF <br />Warehouse <br />27,500 <br />27,500 <br />55,000 <br />27,500 <br />27,500 <br />55,000 <br />5,000 <br />115,000 SF <br />MEZZ FLOOR- Office (includes stairs and 2-story volume lobby <br />3,000 <br />0 <br />5,000 <br />5,000 <br />5,000 <br />10,000 <br />7,000 <br />22,000 SF <br />TOTAL <br />56,615 <br />53,615 <br />112,230 <br />60,823 <br />60,823 <br />121,645 <br />79,369 <br />313,244 SF <br />PARKING REQUIRED <br />% OF OFFICE IN BUILDING <br />8.91% <br />16.44% <br />17.64% <br />OFFICE MAY USE MANUFACTURING PARKING <br />RATIO (2/1000), IF LESS THAN 30% OFFICE <br />9 <br />18 <br />26 <br />53 STALLS <br />OFFICE MAY USE WAREHOUSE PARKING RATIO <br />(1/1000), IF LESS THAN 30% OFFICE <br />5 <br />11 <br />1 <br />17 STALLS <br />MANUFACTURING @ 2/1000 <br />94 <br />93 <br />121 <br />308 STALLS <br />WAREHOUSE @ 1/1000 <br />55 <br />55 <br />5 <br />115 STALLS <br />TOTAL REQUIRED PARKING <br />164 <br />177 <br />153 <br />494 STALLS <br />PARKING PROVIDED <br />STANDARD STALL (8'-6"w. X 18'd.) <br />146 <br />158 <br />138 <br />442 STALLS <br />VAN ACCESSIBLE STALL (9'w. X 18'd. + 8'w. aisle) <br />3 <br />2 <br />1 <br />6 STALLS <br />STANDARD ACCESS.STALL (9'w. X 18'd. + 5'w. aisle) <br />3 <br />6 <br />5 <br />14 STALLS <br />ELECTRIC VEHICLE (EV) (6%) <br />EV STANDARD STALL <br />10 <br />10 <br />9 <br />29 STALLS <br />EV VAN ACCESSIBLE STALL (12'w. X 18'd. + 5'w. <br />aisle) <br />1 <br />1 <br />1 <br />3 STALLS <br />EV STANDARD ACCESS.STALL (9'w. X 18'd. + 5'w. <br />aisle) <br />1 <br />1 <br />1 <br />3 STALLS <br />TOTAL PROVIDED PARKING <br />164 <br />178 <br />155 <br />497 STALLS <br />REQ' LONG TERM BIKE PARKING (5%) <br />8 <br />9 <br />8 <br />25 <br />REQ' SHORT TERM BIKE PARKING (5%) <br />8 <br />9 <br />8 <br />25 <br />PROVIDED LONG TERM BIKE PARKING <br />9 <br />10 <br />8 <br />27 <br />PROVIDED SHORT TERM BIKE PARKING <br />9 <br />10 <br />8 <br />27 <br />CLEAR UNDER BEAM HEIGHT <br />36' <br />36' <br />32' <br />32 Executive, Suite 100 <br />Irvine, CA 92614 <br />T 949.833.3800 - F 949.833.3806 <br />THESE DRAWINGS AND/OR THE ACCOMPANYING SPECIFICATIONS AS <br />INSTRUMENTS OF SERVICE ARE THE EXCLUSIVE PROPERTY OF THE ARCHITECT <br />AND THEIR USE AND PUBLICATION SHALL BE RESTRICTED TO THE ORIGINAL <br />SITE FOR WHICH THEY WERE PREPARED. RE -USE, REPRODUCTION OR <br />PUBLICATION BY ANY METHOD, IN WHOLE OR IN IS PROHIBITED EXCEPT BY <br />WRITTEN PERMISSION FROM THE ARCHITECT. TITLE TO THESE PLANS AND/OR <br />SPECIFICATIONS SHALL REMAIN WITH THE ARCHITECT WITHOUT PREJUDICE. <br />AND VISUAL CONTACT WITH THEM SHALL CONSTITUTE PRIMA FACIA EVIDENCE <br />OF ACCEPTANCE OF THESE RESTRICTIONS. <br />CONSULTANT: <br />PROFESSIONAL SEAL: <br />PROJECT TITLE <br />South Coast <br />Technology Center <br />3100 Lake Center Drive <br />Santa Ana, California <br />APN: 414-261-01 <br />APN(S): 414-272-09; 414-272-10 <br />OWNER/ APPLICANT: <br />.-J ■ SE E l ROM <br />SONS <br />C.J. Segerstrom & Sons <br />a California general partnership <br />3315 Fairview Road <br />Costa Mesa, California 92626 <br />SHEET NAME <br />TITLE <br />SHEET <br />NO: DATE: DESCRIPTION: <br />2023-08-21 <br />1st Submittal Site Plan Review <br />2024-01-22 <br />2nd Submittal Site Plan Review <br />2024-03-08 <br />Mtg. City - Bldg. 1 Fire Access & <br />Bldgs 2 & 3 Unlimited Area <br />2024-04-08 <br />3rd Submittal Site Plan Review <br />2024-04-23 <br />Slip Sheet Changes for Bldg. 3 <br />JOB NO: 22020 <br />DATE ISSUED: 2023-08-21 <br />DRAWN BY: CMH <br />CHECK BY: CMH <br />SHEET NO: <br />2024-04-17 cmh <br />