4321EXPANSION GAP @ GRADEEXPANSION JOINT CAVITYBETWEEN TWOSTRUCTURESAIR FLOW5/8" TYPE "X" GYP. BD, SEESTRUCTURAL FORPLYWOOD SHEAR ASOCCURSF.F.(2) LAYERS 5/8" TYPE "X"GYP BOARD4" <br />MIN AIR SPACEPER PLANSEISMIC EXPANSION JOINT COVER BY M.H.POWELL, MODEL #KH-12-5 .INSTALL PER PER SPECS . SYSTEM SHALLINTEGRATE AND SEAL W/ EXPANSION JOINT ATROOF PER DETAILSWALL PER PLANCONCRETE OR CMU GARAGE WALL PER PLANJ-MOLD, 1/4"-1/2" GAP FILL WITH COMPATIBLESEALANT AND BACKER RODRATED DOOR ASSEMBLY HOLD DOORFRAME OFF THE GROUND TOACCOMODATE EXPANSION JOINT COVERPLATECONCRETE OR CMU GARAGE WALLPER PLAN(2) LAYERS 5/8" TYPE XEXTERIOR GYP. SHEATHING2X CORRIDOR FRAMING,PER STRUCTURALWALL BEYONDSEISMIC EXPANSIONJOINT COVER AT JAMB,BEYONDWOOD SHEATHINGCONCRETE TOPPINGEXPANSION JOINT @ WALL - PLANEXPANSION JOINT @ INTERIOR FLOOR10EXPANSION JOINT @ DOORWALL PER PLANS.A.F.24 GA. CORROSION RESISTANT FLASHING W/ DRIPEDGE O/ SELF-ADHERING WATER PROOF MEMBRANE.LAP FLASHING W/ FLASHING OF JOINT COVER.NOTE: BONDERIZE ALL GALV. SHEET METAL THAT RECEIVESFINISH COATING11EXPANSION JOINT @ ROOFWALL PER PLANNOTE: BONDERIZE ALL GALV. SHEETMETAL THAT RECEIVES FINISH COATINGGALV. SHEET METAL FLASHINGEXPANSION JOINT @ ROOFFIRE BARRIER BLANKET (2-HR FIRE RATED)CONSTRUCTION SPECIALTIES FB-17 SERIESUL SYSTEM NO. WW-D-2032 & WW-D-2034TESTED TO UL-2079, ASTME-1966, ASTME-13993 & 4-WALL PER PLAN123-HR EXPANSION JOINT @ FIREWALL - PLANCONCRETE OR CMU GARAGE WALL PER PLANFIRE BARRIER BLANKET (3-HOUR FIRE RATED) -CONSTRUCTION SPECIALTIES FB-17 SERIESUL SYSTEM NO. WW-D-2032 & WW-D-2034TESTED TO UL-2079, ASTME-1966, ASTME-1399-INSTALL CONTINUOUS FROM TOP OF CONCRETEFOOTING TO UNDERSIDE OF ROOF EXPANSION JOINT.WALL PER PLAN20AD-253 HOUR RATED FIREWALL JAMB PERCONCRETE OR CMU GARAGE WALL PER PLAN2 HOURFIRE BARRIER PER PLANRATED DOOR ASSEMBLY PER PLANDOOR HEAD18NOT USEDDOOR JAMBCONCRETE OR CMU GARAGE WALL PER PLAN19EXPANSION JOINT @ FIRE BARRIER - PLANEXTERIOR PLASTER SYSTEM O/ W.R.B. O/ 5/8" TYPE XEXTERIOR GYPBRD SHTH'G O/ EXTERIOR GRADEPLYWOOD SHTH'GCONCRETE OR CMU GARAGE WALL PER PLANJ-MOLD, 1/4"-1/2" GAP FILL WITH COMPATIBLESEALANT AND BACKER RODEXPANSION JOINT @ EXTERIOR WALL - PLANW.R.B. O/ S.A.F.EXTERIOR PLASTER SYSTEM O/ CONCRETE WALLFIRE RETARDANT FRAMING PER STRUCT. DWGS202 HOURFIRE BARRIER PER PLANAIR SPACE PER PLANFIRE BARRIER BLANKET (2-HR FIRE RATED)CONSTRUCTION SPECIALTIES FB-17 SERIESUL SYSTEM NO. WW-D-2032 & WW-D-2034TESTED TO UL-2079, ASTME-1966, ASTME-1399SEISMIC EXPANSION JOINT COVER BY M.H.POWELL , MODEL #ALHD-12 .INSTALL PER PER SPECS .VAPOR BARRIER BY M.H. POWELL.INSTALL PER PER SPECS .1/8" THICK ALUMINUM COVER ORS.S. 304 0.2 MIL FOILAIR SPACE PER PLANSEISMIC EXPANSION JOINT COVER BY M.H.POWELL, MODEL #KH-12-5 .INSTALL PER PER SPECS .HEADER PER STRUCT. DWGS.FIRE BARRIER BLANKET (2-HR FIRE RATED)CONSTRUCTION SPECIALTIES FB-17 SERIESUL SYSTEM NO. WW-D-2032 & WW-D-2034TESTED TO UL-2079, ASTME-1966, ASTME-1399VAPOR BARRIER BY M.H. POWELL.INSTALL PER PER SPECS .EXPANSION JOINT AT FLOOR, PER DETAIL11-SEISMIC EXPANSION JOINT COVER BY M.H.POWELL, MODEL #KH-12-5 .INSTALL PER PER SPECS .FIRE BARRIER BLANKET (2-HR FIRE RATED)CONSTRUCTION SPECIALTIES FB-17 SERIESUL SYSTEM NO. WW-D-2032 & WW-D-2034TESTED TO UL-2079, ASTME-1966, ASTME-1399VAPOR BARRIER BY M.H. POWELL.INSTALL PER PER SPECS .CONCRETE OR CMU GARAGE WALL PER PLAN2 HOURFIRE BARRIER PER PLANSEISMIC EXPANSION JOINT COVER BY M.H.POWELL, MODEL #KH-12-5 .INSTALL PER PER SPECS .FIRE BARRIER BLANKET (2-HR FIRE RATED)CONSTRUCTION SPECIALTIES FB-17 SERIESUL SYSTEM NO. WW-D-2032 & WW-D-2034TESTED TO UL-2079, ASTME-1966, ASTME-1399VAPOR BARRIER BY M.H. POWELL.INSTALL PER PER SPECS .(2) LAYERS 5/8" TYPE X GYPBRD SHTH'GSEISMIC EXPANSION JOINT COVER BY M.H.POWELL, MODEL #KH-12-5 .INSTALL PER PER SPECS .FIRE BARRIER BLANKET (2-HR FIRE RATED)CONSTRUCTION SPECIALTIES FB-17 SERIESUL SYSTEM NO. WW-D-2032 & WW-D-2034TESTED TO UL-2079, ASTME-1966, ASTME-1399VAPOR BARRIER BY M.H. POWELL.INSTALL PER PER SPECS .VAPOR BARRIER BY M.H. POWELL.INSTALL PER PER SPECS .SEISMIC EXPANSION JOINT COVER BY M.H.POWELL, MODEL #RW-12 .INSTALL PER PER SPECS .SEISMIC EXPANSION JOINT COVER BY M.H.POWELL , MODEL #RPW-12 .INSTALL PER PER SPECS .AIR SPACE PER PLANAIR SPACE PER PLANAIR SPACE PER PLANFIRE BARRIER BLANKET (2-HR FIRE RATED)CONSTRUCTION SPECIALTIES FB-17 SERIESUL SYSTEM NO. WW-D-2032 & WW-D-2034TESTED TO UL-2079, ASTME-1966, ASTME-1399VAPOR BARRIER BY M.H. POWELL.INSTALL PER PER SPECS .GALV. SHEET METAL FLASHINGWALL PER PLANHATCH INDICATES FIRERETARDANT-TREATED LUMBERHATCH INDICATES FIRERETARDANT-TREATED LUMBERHATCH INDICATES FIRERETARDANT-TREATED LUMBERHATCH INDICATES FIRERETARDANT-TREATED LUMBERHATCH INDICATES FIRERETARDANT-TREATEDLUMBERHATCH INDICATES FIRERETARDANT-TREATED LUMBERHATCH INDICATES FIRE RETARDANT-TREATED LUMBERHATCH INDICATES FIRERETARDANT-TREATED LUMBERCCOPYRIGHTIt is the clients responsibility prior to or during construction to notify the architect in writingof any perceived errors or omissions in the plans and specifications of which a contractorthoroughly knowledgeable with the building codes and methods of construction shouldreasonably be aware. Written instructions addressing such perceived errors or omissionsshall be received from the architect prior to the client or clients subcontractors proceedingwith the work. The client will be responsible for any defects in construction if theseprocedures are not followed.Architecture + Planning17911 Von Karman Ave.Suite 200Irvine, CA 92614ktgy.com949.851.2133License StampProject Contact:Email:Principal: Project Designer:Project Director:KTGY Project No:2017-0934Debbie Hollanddholland@ktgy.comWil WongD. SchoolmeesterDebbie HollandDeveloperPHONE NO.4199 CAMPUS DRIVEIRVINE, CA 92612(714) 342-2502415 & 515 E. 4TH STREET, SANTA ANA, CA 92701 <br />4TH AND MORTIMERNo.Date Description06-21-2023 FIFTH BUILDING DEPARTMENT SUBMITTALA03-21-23ADDENDUM AAD-33EXPANSION JOINTDETAILS06-21-23