P.ESOI,UTIO~.~ 93-002 <br />Page 3 <br /> <br />(7) Plastic pipe - Plastic pipe shall be supported at not <br />to exceed four (4) feet (1.2 m) on centers, at end of <br />branches, and at change of direction or elevation. <br />Supports shall allow free movement, but shall restrict <br />upward movement of lateral runs so as to not create <br />reverse grade. <br /> <br />(8) Suspended lines shall be suitably braced at no more <br />than forty (40) foot intervals to prevent horizontal <br />movement. <br /> <br />(c) Hangers and Anchors <br /> <br />(1) Material - Hangers and anchors shall be of material <br />of sufficient strength to maintain their proportional <br />share of the weight of pipe and contents. <br /> <br />(2) Ail piping, fixtures, and equipment shall be <br />adequately supported to the satisfaction of the <br />Administrative Authority. <br /> <br />(3) Ail horizontal cast iron drain, waste and vent <br />piping, and all other horizontal piping 2½" and larger, <br />shall be supported with approved rod and hangers, in <br />accordance with Subsection (b) of this Section and with <br />the following table: <br /> <br />PIPE/TUBE SIZE <br /> <br />MINIMUM ROD SIZE <br /> <br />(Larger) <br /> <br />(Engineered) <br /> <br />Exception: Plumbers tape (perforated strap iron) may be used to <br />support piping 2" and smaller in type V construction only. Plumbers <br />tape shall be galvanized and not less than ~" wide and 22 gauge. <br /> <br /> 2. The city Council hereby finds and determines that the <br />above amendment to section 316 of the Uniform Plumbing Code, 1991 <br />edition, is necessary for the following reasons: <br /> <br />This amendment is intended to provide for a more <br />effective and consistent system of pipe support for <br />piping used in plumbing and piping systems. This is <br />deemed necessary in Santa Ana because of the significant <br />potential for damage due to seismic activity. Santa Ana <br />is in close proximity to major active fault systems in <br />Southern California, and the Uniform Building Code <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.