RESOLUTION 95-081 315 <br /> <br />Ail sections of this National Electrical Code allow- <br />ing the use of aluminum conductors are subject to <br />the limitation that no aluminum conductor smaller <br />than No. 6 AWG shall be used. <br /> <br /> The City Council hereby finds and determines that earthquakes <br />are a common occurrence in the local area; that earthquakes may <br />cause electrical connections and screws to loosen, causing heat <br />problems especially in the smaller sizes of aluminum wire; and that <br />the above amendment is necessary to address the risk of fire due to <br />such causes. <br /> <br /> 4. Section 8-942 of the Santa Ana Municipal Code amends, and <br />will continue to amend, section 336-4 of the National Electrical <br />Code to read as follows: <br /> <br />336-4. Uses Not Permitted. <br /> <br /> (a) Type NM or NMe. Types NM and NMC cables shall <br />not be used: (1) in any dwelling or structure ex- <br />ceeding three floors above grade; (2) as service- <br />entrance cable; (3) in any nonresidential building <br />or structure; (4) in hoist-ways; or (5) embedded in <br />poured cement, concrete, or aggregate. For the <br />purpose of this article, the first floor of a build- <br />ing shall be that floor that has fifty percent or <br />more of the exterior wall surface area level with or <br />above finished grade. One additional level that is <br />the first level and not designed for human habita- <br />tion and used only for vehicle parking, storage, or <br />similar use shall be permitted. <br /> <br />(b) Type NM. Type NM cable shall not be installed: <br />(1) where exposed to corrosive fumes or vapors; (2) <br />where embedded in masonry, concrete, adobe, fill, or <br />plaster; (3) in a shallow chase in masonry, con- <br />crete, or adobe and covered with plaster, adobe, or <br />similar finish. <br /> <br /> The City Council finds and determines that earthquakes are a <br />common occurrence in the local area; that, unlike wire installed in <br />conduit or raceways, non-metallic sheathed cable does not provide <br />the degree of protection that is needed in the event of an <br />earthquake; that exposed non-metallic sheathed cable is particular- <br />ly hazardous; and that this amendment is necessary to assure that <br />adequate protection is provided in the workplace and in other <br />places of public gathering. <br /> <br /> 5. The Clerk of the Council is directed to file a certified <br />true copy of this resolution with the Department of Housing and <br />Community Development of the State of california. <br /> <br />3 <br /> <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.