My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
75D - WATER QUALITY REPORT
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2004
>
07/06/2004
>
75D - WATER QUALITY REPORT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2012 5:02:03 PM
Creation date
7/2/2004 5:27:59 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Item #
75D
Date
7/6/2004
Destruction Year
2009
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
6
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Guidelines Followed: <br /> <br />The Association of California Water Agencies (ACWA) formed a work group, which <br />prepared guidelines for water utilities to use in preparing these required reports. The ACW A <br />guidelines were used in the preparation of this report. <br /> <br />Best Available Technology and Cost Estimates: <br /> <br />Both the USEPA and CDHS adopt what are known as BATs or Best Available <br />Technology, which are the best known methods of reducing contaminant levels to the MCL. <br />Costs can be estimated for such technologies. However, since many PHGs and all MCLGs are <br />set lower than the MCL, it is not always possible nor feasible to detennine what treatment is <br />needed to further reduce a constituent downward to or near the PHG or MCLG, many of which <br />are set at zero. Estimating the costs to reduce a constituent to zero is difficult, if not impossible <br />because it is not possible to verify by analytical means that the level has been lowered to zero. In <br />some cases, installing treatment to try and further reduce very low levels of one constituent may <br />have adverse effects on other aspects of water quality. <br /> <br />Constituents Detected That Exceed a PHG or a MCLG: <br /> <br />The following is a discussion of constituents that were detected in one or more of our <br />drinking water sources at levels above PHG. <br /> <br />Naturally Occurring Uranium <br /> <br />The PHG for Natural Uranium is 0.43 pCi/L. The MCL or drinking water standard for <br />Natural Uranium is 20 pCiIL. We have detected Natural Uranium in 13 of our 20 wells at levels <br />3.0 to 11.4 pCi/L. The levels detected were below the MCL. The category of health risk <br />associated with Natural Uranium, and the reason that a drinking water standard was adopted for <br />it, is that people who drink water containing Natural Uranium above the MCL throughout their <br />lifetime could experience an increased risk of cancer. The 20 pCi/L MCL established by the <br />CDHS if complied with should have no adverse health effect. The numerical risk for cancer for <br />water containing Uranium at the PHG level of 0.43 pCiIL is one case in ] ,000,000. The large <br />water system BAT for Natural Uranium to lower the levels below the PHG is Ion Exchange. <br />Total water production for all affected wells is 32,446 gallons per minute. Based on the USEPA <br />studies, the initial cost to treat one thousand gallons of water at 80 percent removal efficiency for <br />large water systems ranges from $0.54 to $1.68. The on going cost for the treatment ranges from <br />$0.54 to $0.66 per thousand gallons of water treated. For the City of Santa Ana, the estimated <br />cost to install such treatment systems (Ion Exchange) ranges between $6.45 and $20.0 Million. <br />The cost to operate the treatment facilities will range from $6.45 to $7.9 million per year. The <br />cost to build the treatment facilities would result in an assumed increased cost for each customer <br />of$18.53 to $57.45 in the first year and from $18.50 to $22.70 per customer annually. <br /> <br />2 <br />75D-4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.