Laserfiche WebLink
<br />. <br /> <br />57. Prior to the issuance of grading permits, the project developer shall submit <br />a Final Water Quality Management Plan (WQMP) based on the Final <br />Grading Plan, to be approved by the City's Director of Public Works. The <br />WQMP shall be consistent with the DAMP and shall contain provisions <br />and BMP's for construction and operation conditions. <br /> <br />58. Prior to the issuance of building permits, the project developer shall pay <br />the City's drainage impact fee. <br /> <br />59. Prior to the issuance of grading permits, the project developer shall verify <br />that structural BMP's have been permanently incorporated into project <br />plans. Such BMP's shall ensure that pollutants from project-related storm <br />water runoff are mitigated consistently with applicable state and local <br />standards. <br /> <br />60. Prior to issuance of grading permits, the project developer shall submit a <br />final drainage plan to the City identifying the exact size and location of <br />drainage facilities. <br /> <br />61. Prior to issuance of grading permits, the project developer shall provide <br />proof of an NPDES permit from RWQCB to the City for onsite dewatering <br />activities. <br /> <br />. <br /> <br />62. Prior to issuance of building permits for tenant improvements for <br />restaurant uses, the project developer shall ensure that the proposed <br />restaurants are fitted with grease interceptors to the size and capacity as <br />designated by the City of Santa Ana Building Division. <br /> <br />63. Prior to issuance of building permits, building plans shall reflect the <br />construction of noise barriers to ensure an exterior noise level of 65 CNEL <br />or less around patios and balconies that are considered open space by <br />the City of Santa Ana. The barriers shall be constructed of materials that <br />provide a surface density of at least four pounds per square foot and shall <br />be continuous (without gaps or gates). The height of the barriers shall be <br />sufficient to reduce the exterior noise level to a CNEL of 65 dB or less, <br />and shall be determined by a qualified acoustical consultant as part of the <br />final engineering design of the project. <br /> <br />64. Prior to issuance of building permits, building plans shall specify the STC <br />rating of windows and doors for all residential land uses. Window and <br />door ratings shall be sufficient to reduce the interior noise level to a CNEL <br />of 45 dB or less, and shall be determined by a qualified acoustical <br />consultant as part of the final engineering design of the project. <br /> <br />. <br /> <br />Exhibit "B" <br />Page 9 of 15 <br />