My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
31A - 3770 W. MCFADDEN AVE.
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2005
>
09/06/2005
>
31A - 3770 W. MCFADDEN AVE.
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2012 4:52:49 PM
Creation date
8/31/2005 10:48:17 AM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Item #
31A
Date
9/6/2005
Destruction Year
2010
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
76
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />would not displace existing public transportation <br />facilities. <br /> <br />XVI. UTILITIES <br /> <br />A. Exceed wastewater treatment requirements of the <br />applicable Regional Water Quality Control Board? <br /> <br />B. Require or result in the construction of new water or <br />wastewater treatment facilities or expansion of existing <br />facilities, the construction of which could cause <br />significant environmental effects? <br /> <br />E. Result in the determination by the wastewater treatment <br />provider, which serves or may serve the project that it <br />has adequate capacity to serve the project's projected <br />demand in addition to the providers existing commitments. <br /> <br />Less Than Significant Impact <br /> <br />The City of Santa Ana and/or the Orange County Sanitation <br />District would provide wastewater service to the project <br />site. The treatment of wastewater would be provided at <br />Reclamation Plant 1 in the City of Fountain Valley. The <br />proposed project would be required to provide appropriate <br />sewer connection fees. The proposed project would not <br />significantly increase the demand for additional wastewater <br />facilities. <br /> <br />C. Require or result in the construction of new storm <br />water drainage facilities or expansion of existing <br />facilities, the construction of which could cause <br />significant effects. <br /> <br />Less Than Significant Impact <br /> <br />The project site is situated within an area that is <br />currently improved with drainage facilities. Implementation <br />of the proposed project would not significantly increase <br />the amount of surface water runoff generated from the <br />project site. Implementation of the proposed project would <br />not require the construction of new drainage facilities <br />that would impact the environment. <br /> <br />D. Are sufficient water supplies available to serve the <br />project from existing entitlements and resources or <br />are new or expanded entitlements needed? <br /> <br />24 <br /> <br />31A-48 <br />
The URL can be used to link to this page
Your browser does not support the video tag.