Laserfiche WebLink
VTTM No. 2024-02 and DBA No. 2024-02 — Santa Ana-8 Townhomes (510 & 520 N. <br />Harbor Blvd.) <br />December 9, 2024 <br />Page 8 <br />Table 4: Analvsis of the Requested Concession (1) and Waivers (3) <br />Standard <br />Analysis <br />Building Frontage <br />(Concession) - SP-2, Ch. 3, Frontyard/Porch Frontage Type, 1 <br />SP-2 requires minimum floor heights based on proposed frontage type (e.g., <br />Ground Floor Height <br />forecourt, stoop, etc.). The project proposes a frontyard/porch frontage type with <br />9'-1" ground floor height and is below the minimum 10' required. <br />The project's location in a flood zone necessitates raising the site's base flood <br />elevation, impacting ground floor -to -ceiling heights. To comply with flood <br />regulations, interior floor levels must be elevated, reducing first -floor ceiling <br />heights. Maintaining the proposed unit count while adhering to these <br />requirements would require a redesign, potentially leading to fewer residential <br />units, affecting the project's density and efficiency. Moreover, SP-2 was originally <br />intended to achieve a specific urban form, and since existing nearby multi -family <br />residential developments do not maintain a minimum building floor height, the <br />proposed design is consistent with the existing multi -family residences. <br />The minimum dimensions for porch type building frontages is 6' depth. No <br />Dimension — Depth <br />porches fully meet these requirements. <br />Modifying porch depth is challenging due to the flood zone location. Changes <br />would require building reconfiguration to accommodate proper stairs from street <br />level, given elevated floor requirements. This would affect unit layouts, disrupting <br />the efficient stacked floor plan and potentially reducing interior space and <br />bedroom counts. <br />Dimension — Width <br />The minimum dimensions for porch type building frontages is 10' width if an <br />asymmetrical entry. No porches fully meet these requirements. <br />Modifying porch width is challenging due to the flood zone location. Changes <br />would require building reconfiguration to accommodate proper stairs from street <br />level, given elevated floor requirements. This would affect unit layouts, disrupting <br />the efficient stacked floor plan and potentially reducing interior space and <br />bedroom counts. <br />Open Space <br />(Waivers) - SP-2, Ch. 3, Table 3-9. Onsite Open Space Requirements <br />The total common open space required for the project site (net) is equal to 15 <br />Common — Area <br />percent of the lot, or approximately 12,290 sq. ft. Instead, the project provides a <br />3,853 sq. ft. of common open space (approximately 5 percent), which is a <br />difference of 8,437 sq. ft. or 10 percent. <br />Meeting the minimum required open space would eliminate six or more units, <br />affecting project feasibility. To maintain the proposed unit count, the developer <br />would need to modify the building type and construct additional floors, potentially <br />exceeding the maximum allowable height in the Harbor Mixed Use Transit <br />Corridor Plan (SP-2) and increasing development costs. To help alleviate the <br />open space deficiency, the project proposes an average of 174 sq. ft. of private <br />open space per unit, through private balconies/decks. <br />