Laserfiche WebLink
Responses to <br />Environmental Checklist <br />For CEQA Compliance <br />No Impact <br />According to the City's General Plan Land Use Element EIR the project site does not contain any unique <br />geologic features. Therefore, implementation of the proposed project would not result in adverse impacts <br />to any unique geologic feature. <br />D. Is the project located on strata or soil that is unstable or that would become unstable as a <br />result of the project and potentially result in on-or off-site landslide, lateral spreading, <br />subsidence, liquefaction or collapse? <br />E. Is the project located on expansive soils creating substantial risks to life and property? <br />Less Than Significant Impact <br />According the City's General Plan Land Use Element EIR, the project site is located on soils that have <br />high/very high shrink /swell potential, high corrosion potential to uncoated steel and low corrosion <br />potential to concrete. The soil conditions on the project site would not provide a constraint that would <br />prevent the development of the proposed project. As part of the City's development review process a <br />geotechnical study is required to be prepared to identify geotechnical design recommendations to ensure <br />the long-term geotechnical stability of the project site as well as the recommendations for site preparation, <br />foundations and overall structural design specific to this project. The report will address the issues of <br />liquefaction, differential settlement, and soils sampling and testing for expansive soils as they apply to the <br />current project and provide recommendations for foundation design which will address any stability or <br />expansive soils issues. Compliance with all the recommendations contained in the report, and <br />compliance with Chapter 33 of the 2007 CBC, project impacts would be reduced to a less than significant <br />level. <br />F. Where sewers are not available for the disposal of wastewater is the soil capable of <br />supporting the use of septic tanks or alternative wastewater disposal systems? <br />No Impact <br />The City of Santa Ana will provide sanitary sewer services to the proposed project. Accordingly, the <br />project will not use septic tanks or alternative wastewater systems to dispose of wastewater and no <br />impact would occur. <br />VII. Hazards and Hazardous Materials <br />A. Create a significant hazard to the public or the environment through the routine transport, <br />use or disposal of hazardous materials? <br />B. Create a significant hazard to the public or the environment through reasonably <br />foreseeable upset and accident conditions involving likely release of hazardous materials <br />into the environment? <br />C. Reasonably be anticipated to emit hazardous emissions or handle hazardous or acutely <br />hazardous materials, substance or waste within one-quarter mile of an existing or <br />proposed school? <br />D. Is the project located on a site which is located on a list of hazardous material sites <br />compiles pursuant to Government Code Section 659662.5 and, as a result, would it create <br />a significant hazard to the public or the environment? <br />No Impact <br />75A-45 <br />