My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
25E - FIRE ALARM SYSTEMS
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2009
>
07/06/2009
>
25E - FIRE ALARM SYSTEMS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2012 4:18:15 PM
Creation date
7/1/2009 2:53:22 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Item #
25E
Date
7/6/2009
Destruction Year
2014
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2.1.1 Service personnel shall be factory trained and certified to test and <br />maintain fire alarm systems in the state of California. <br />2.1.2 Service personnel shall be National Institute for Certification in <br />Engineering Technologies (NICET) certified in the field of Fire <br />Protection Engineering Technology. (Level 2, minimum) <br />2.1.3 Service personnel shall have two (2) or more years experience <br />performing service work on Fire Alarm Systems. <br />2.2 Service personnel shall be knowledgeable of current National Fire Protection <br />Association (NFPA) codes and how they affect fire alarm systems. <br />2.3 Service personnel shall be capable of demonstrating, upon request, the proper <br />trouble shooting techniques, service procedures and testing procedures for the <br />Fire Alarm Systems. <br />3. Testing/Inspection Personnel <br />3.1 The Company shall employ testing/inspection personnel (identified in the <br />following as inspection personnel) as full-time fire alarm inspectors. <br />3.2 The Lead Inspector shall be factory trained and certified to perform all NFPA <br />required testing procedures. <br />4. Design Engineering Personnel <br />4.1 Engineering personnel shall be factory trained and certified. <br />4.2 Engineering personnel shall be NICET certified. <br />II. SERVICES <br />1. Test and Inspections <br />1.1 Annual test and inspections of the fire alarm systems shall include, but not be <br />limited to, the following: <br />• Sensitivity testing of smoke detectors as follows: <br />- Smoke detectors shall be internally cleaned by using a vacuum device <br />and the exterior cleaned with approved solution. <br />- Smoke detectors shall be checked for proper sensitivity with <br />manufacturer's calibrated Sensitivity Test Instrument. <br />Rev: 3/27/2009 <br />25E-11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.