SIMPLEX/GRINNELL, LP 5 - 2009
Clerk
>
Contracts / Agreements
>
_PENDING FOLDER
>
READY TO DESTROY IN 2018
>
SIMPLEX/GRINNELL, LP 5 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2017 2:06:34 PM
Creation date
8/14/2009 8:24:30 AM
Metadata
Fields
Template:
Contracts
Company Name
SIMPLEX GRINNELL
Contract #
A-2009-105
Agency
FINANCE & MANAGEMENT SERVICES
Council Approval Date
7/6/2009
Expiration Date
6/30/2010
Insurance Exp Date
10/1/2010
Destruction Year
2017
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2.1.1 Service personnel shall be factory trained and certified to test and <br />maintain fire alarm systems in the state of California. <br />2.1.2 Service personnel shall be National Institute for Certification in <br />Engineering Technologies (NICET) certified in the field of Fire <br />Protection Engineering Technology. (Level 2, minimum) <br />2.1.3 Service personnel shall have two (2) or more years experience <br />performing service work on Fire Alarm Systems. <br />2.2 Service personnel shall be knowledgeable of current National Fire Protection <br />Association (NFPA) codes and how they affect fire alarm systems. <br />2.3 Service personnel shall be capable of demonstrating, upon request, the proper <br />trouble shooting techniques, service procedures and testing procedures for the <br />Fire Alarm Systems. <br />3. Testing/Inspection Personnel <br />3.1 The Company shall employ testinglinspection personnel (identified in the <br />following as inspection personnel) as full-time fire alarm inspectors. <br />3.2 The Lead Inspector shall be factory trained and certified to perform all NFPA <br />required testing procedures. <br />4. Design Engineering Personnel <br />4.1 Engineering personnel shall be factory trained and certified. <br />4.2 Engineering personnel shall be NICET certified. <br />II. SERVICES <br />1. Test and Inspections <br />1.1 Annual test and inspections of the fire alarm systems shall include, but not be <br />limited to, the following: <br />• Sensitivity testing of smoke detectors as follows: <br />➢ Smoke detectors shall be internally cleaned by using a vacuum device <br />and the exterior cleaned with approved solution. <br />➢ Smoke detectors shall be checked for proper sensitivity with <br />manufacturer's calibrated Sensitivity Test Instrument. <br />Rec_ 3/2712009 <br />