SIMPLEX/GRINNELL, LP 5 - 2009
Clerk
>
Contracts / Agreements
>
_PENDING FOLDER
>
READY TO DESTROY IN 2018
>
SIMPLEX/GRINNELL, LP 5 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/9/2017 2:06:34 PM
Creation date
8/14/2009 8:24:30 AM
Metadata
Fields
Template:
Contracts
Company Name
SIMPLEX GRINNELL
Contract #
A-2009-105
Agency
FINANCE & MANAGEMENT SERVICES
Council Approval Date
7/6/2009
Expiration Date
6/30/2010
Insurance Exp Date
10/1/2010
Destruction Year
2017
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
➢ Smoke detectors that do not pass the first sensitivity test, shall be <br />dismantled, cleaned internally with approved solution and retested. <br />➢ Smoke sensitivity testing and cleaning shall be performed in such a <br />manner that all smoke detectors will be tested for proper sensitivity, <br />upon completion of the second year. Minimum 50% per year. <br />➢ All peripheral equipment shall be functionally tested for proper alarm <br />operation. Minimum 100% per year. <br />➢ One device on each initiating and signaling zone shall be disconnected <br />to determine proper supervision wiring. <br />➢ All control equipment and auxiliary functions shall be checked for <br />proper response to trouble and alarm conditions (Le., City Response, <br />AHU Shut -down). <br />➢ All control equipment shall be tested for proper voltages during trouble <br />and alarm conditions. <br />All batteries must be tested under load for the required time period to <br />ensure proper operation. <br />➢ Provide complete documentation of the entire fire alarm inspection and <br />test, listing all peripheral equipment (by location, device type, alarm <br />zone, sensitivity test results) and listing discrepancies (including any <br />repairs made while on-site). <br />➢ All inspection, functional testing, and audit functions must be performed <br />in accordance with respective nationally recognized standards (NFPA <br />72), and state fire codes. <br />1.2 Documentation that documents the above tests, (including but not limited to) <br />individual peripheral locations along with their sensitivity test results (rating <br />versus actual) and individual zone test results (normal versus abnormal) must be <br />submitted at the time of the testlinspection. <br />1.3 Tests and inspections shall be performed, utilizing two (2) company qualified <br />personnel. The representatives shall be present during the entire inspection and <br />utilize the following equipment supplied by the Company. <br />1.3.1 Two (2), two-way radios <br />1.3.2 "Gemini" or equivalent smoke detector sensitivity tester <br />1.3.3 Decibel meter <br />1.3.4 Controlled temperature heat detector tester for fixed temperature and <br />rate of rise heat detectors <br />1.3.5 Testing signs (free standing to be placed at entrance of building, <br />minimum 2'x 2'). <br />Rev_ 327(2009 <br />