My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
75A - PH - RESO AND ORDINANCE ADOPTING BUILDING AND FIRE CODES
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2010
>
10/18/2010
>
75A - PH - RESO AND ORDINANCE ADOPTING BUILDING AND FIRE CODES
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2012 3:58:50 PM
Creation date
10/14/2010 1:05:33 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Item #
75A
Date
10/18/2010
Destruction Year
2015
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
2. All stairways shall be completely enclosed with one-hour <br />construction to exits: and enclosed stairways or required exits shall lead <br />directly to the outside of the building. <br />3. Draft stops are required in floors in accordance with Section 717 3 <br />In attic areas. one-hour walls shall be required for every one thousand <br />X1,000) square feet of area. <br />4. Smoke detectors with an alarm system receiving their primary <br />power from the building wiring shall be required throughout the building in <br />accordance with NFPA standards. <br />5. Either (a) corridors. regardless of occupant load shall be one-hour <br />construction: or (b) a "life safety" sprinkler system. as approved by the fire <br />department. shall be installed in all corridors. <br />SECTION 25: That section 8-152 of the Santa Ana Municipal Code is hereby amended <br />such that it reads as follows (new language underlined, deleted language in strikeout for tracking <br />purposes only): <br />Sec. 8-152. ,°?°?? Fire protection requirements (Volume 2. Section 3405) <br />The first paragraph of Section 3405 of the building code is amended by adding <br />thereto the following: <br />EXCEPTION: If additions, alterations or repairs made to any building constructed <br />prior to January 1 , 1946, other than an R-occupancy building exceed fifty <br />thousand dollars ($50.000.00) in cost in any one-year period then either (A) the <br />entire building must be completely sprinklered in accordance with fire department <br />standards or (B) the building must comply with all the following requirements <br />1. The ceiling of a roof system shall be of one-hour construction and <br />all ceiling or wall penetrations shall have approved fire dampers. <br />2. All stairways shall be completely enclosed with one-hour <br />construction to exits: and enclosed stairways or required exits shall lead <br />directly to the outside of the building. <br />3. Draft stops are required in floors in accordance with Section 717.3. <br />In attic areas. one-hour walls shall be required for every one thousand <br />??000) square feet of area. <br />4. Smoke detectors with an alarm system receiving their primary <br />power from the building wiring shall be required throuahout the building in <br />accordance with NFPA standards. <br />Ordinance No. NS-XXXX <br />7e A _?f? Page '15 of 50
The URL can be used to link to this page
Your browser does not support the video tag.