My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
11A - ORDINANCE - BUILDING CODE
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2010
>
11/15/2010
>
11A - ORDINANCE - BUILDING CODE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2012 3:57:41 PM
Creation date
11/10/2010 7:58:39 AM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Item #
11A
Date
11/15/2010
Destruction Year
2015
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br /> <br /> <br /> <br /> <br /> <br /> SECTION 25: That section 8-152 of the Santa Ana Municipal Code is hereby amended <br /> such that it reads as follows: <br /> Sec. 8-152. Fire protection requirements (Volume 2, Section 3405) <br /> <br /> The first paragraph of Section 3405 of the building code is amended by adding <br /> thereto the following: <br /> <br /> EXCEPTION: If additions, alterations or repairs made to any building constructed <br /> prior to January 1, 1946, other than an R-occupancy building, exceed fifty <br /> thousand dollars ($50,000.00) in cost in any one-year period, then either (A) the <br /> entire building must be completely sprinklered in accordance with fire department <br /> standards, or (B) the building must comply with all the following requirements: <br /> <br /> 1. The ceiling of a roof system shall be of one-hour construction, and <br /> all ceiling or wall penetrations shall have approved fire dampers. <br /> <br /> 2. All stairways shall be completely enclosed with one-hour <br /> construction to exits; and enclosed stairways or required exits shall lead <br /> directly to the outside of the building. <br /> <br /> 3. Draft stops are required in floors in accordance with Section 717.3. <br /> In attic areas, one-hour walls shall be required for every one thousand <br /> (1,000) square feet of area. <br /> <br /> 4. Smoke detectors with an alarm system, receiving their primary <br /> power from the building wiring, shall be required throughout the building in <br /> accordance with NFPA standards. <br /> <br /> 5. Either (a) corridors, regardless of occupant load, shall be one-hour <br /> construction; or (b) a "life safety" sprinkler system, as approved by the fire <br /> department, shall be installed in all corridors. <br /> <br /> SECTION 26: That section 8-184 of the Santa Ana Municipal Code is hereby deleted in its <br /> entirety: <br /> <br /> Sec. 8-184. Reserved. <br /> <br /> SECTION 27: That section 8-290 of the Santa Ana Municipal Code is hereby amended <br /> such that it reads as follows: <br /> <br /> Sec. 8-290. Adoption by reference. <br /> <br /> There is adopted by the city that certain code known as the California Plumbing <br /> Code, 2010 Edition, including the following appendices thereto: A, B, D, I and K, <br /> (hereinafter referred to in this article as the "Plumbing Code"), together with subsequent <br /> <br /> <br /> Ordinance No. NS-XXXX <br /> 11A-12 Page 12 of 43 <br />
The URL can be used to link to this page
Your browser does not support the video tag.