Laserfiche WebLink
' BENDER READY-MIX CONCRETE MANUFACTURING PROJECT <br />Initial Study/Mitigated Negative Declaration <br />Project-Related Sources of Greenhouse Gases <br /> <br />w <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br />I <br /> <br /> <br /> <br /> <br /> <br /> <br />Direct project-related GHG emissions include emissions from construction activities, area sources, and <br />mobile sources. Table 4.7-1, Estimated Greenhouse Gas Emissions, presents the estimated C02, N20, <br />and CH4 emissions of the proposed project. GHG emissions from construction are typically amortized <br />over the lifetime of the project (30 years) and added to the operational emissions.4 As seen in Table <br />4.7-1, the proposed project would result in a total of 7.25 MTC02eq/yr from construction activities. <br />Following construction, no other GHG emissions would result with project implementation, as no new <br />vehicle trips would result and no new stationary sources are proposed. However, GHG emissions <br />associated with the existing facility operations have been quantified and are presented in Table 4.7-1. <br />GHGs associated with area sources and mobile sources are 160.00 MTC02eq/yr and 295.80 <br />MTC02eq/yr, respectively. Total project-related direct operational emissions equate to 456.22 <br />MTC02eq/yr. <br />Table 4.7-1 <br />Estimated Greenhouse Gas Emissions <br />a?,.'?a' ?N .p?CVz.? ;Y # 4+t?jQ yK r?7.G.r t C1 F{ <br /> elrlc Eric ->>Tons,:, c lNf?c?Tons <br /> tonsryr of, py/yrzt 5 tijnalyr efC rz a^CO:edtyr.- <br />DIRECT EMISSIONS <br />Construction Emissions' <br />2011 6.50 0,00 0.01 0.00 0.74 7.25 <br />Total Amortized Construction Emissions <br /> <br />(30 years) 0.22 0.00 0.00 0.00 0.20 0.42 <br />Area Source Emissions 160.00 0.00 0.00 0.00 0.00 160.00 <br />Mobile Source Emissions' 273.0 0.07 22.49 0.01 0.31 295.80 <br />INDIRECT EMISSIONS <br />Electricity Consumption 8.85 0.00 0.03 0.00 0.01 8.89 <br />Water Supply 0.36 0.00 0.00 0.00 0.00 0.36 <br />Total Project-Related GHG Emissions 465.47 MTCOseq/yr <br />GHG Threshold of Significance 1,100 MTCO:eq/yr <br />Significance of Impact Less Than Significant <br />Notes: <br />1. Emissions calculated using CARB's Construction Equipment Emissions Table and the URBEMIS 2007 computer model. <br />2. C02 Equivalent values calculated using the U.S. Environmental Protection Agency Website, Greenhouse Gas Equivalencies Cakulator, <br />htt <br />_ p:/hvww.epa.gov/cleanenergy/energy-resources/gkulator.html, accessed January 2011. <br />r <br />Refer to Appendix A, Air QualitylGreenhouse Gases Data, for detailed model imut(outout data. <br />Indirect Project-Related Sources of Greenhouse Gases <br />Electricity Consumption <br />Energy Consumption emissions were calculated using the South Coast Air Quality Management <br />District's (SCAQMD) CEQA Air Quality Handbook,5 the U.S. Energy Information Administration ,6 and <br />project-specific land use data. The emission factors for electricity use (771.62 pounds of C02 per <br />megawatt hour [MWh], 0.00659 pounds of N20 per MWh, and 0.4037 pounds of CH4 per MWh) were <br />4 The project lifetime is based on the standard 30 year assumption of the South Coast Air Quality Management District <br />(http:/hvww.agmd.gov/hb/2008/December/081231 a.htm). <br />5 SCAQMD's CEQA Air Quality Handbook, Table A9-11, November 1993. <br />6 U.S. Energy Information Administration, Domestic Electricity Emissions Factors 1999-2002. <br />JULY 2011 <br />4,7-3 GREENHOUSE GASES <br />31A-59