My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
UNITED STORM WATER, INC. -2011
Clerk
>
Contracts / Agreements
>
U
>
UNITED STORM WATER, INC. -2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/8/2020 1:23:02 PM
Creation date
3/7/2012 5:29:20 PM
Metadata
Fields
Template:
Contracts
Company Name
$Lookup1_NAME$
Contract #
A-2011-253
Agency
Public Works
Council Approval Date
11/28/2011
Expiration Date
6/30/2012
Insurance Exp Date
12/31/2012
Destruction Year
2017
Notes
$Lookup1_AMENDS$
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
19
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
accumulates at the site. Field inspections of catch basins will determine if this product is appropriate for each <br />respective storm drain. <br />Regulatory Permits Required for Installation <br />No regulatory permits are required for the installation of this product. <br />Maintenance Requirements <br />For best performance of the DrainPac'm United Storm Water recommends cleaning by means of industrial vacuum <br />(usually does not require confined space entry) once during the dry season (June-September) and as often as <br />monthly during the wet season (October-May) for effective filtration and to prevent the possibility of flooding. <br />Average number of cleanings is three to four per year. Cleaning is particularly important prior to the wet season <br />and after the first storm event of 314° of rain to prevent the possibility of flooding. Actual scheduling will be based <br />on United recommendations and customer approval based on county stormwater management ordinances and the <br />storm drain flows and loads subjected to the site. <br />Per the local Stormwater Management and Discharge Control Ordinance, BMPs at manned facilities must be <br />inspected by the discharger before and following predicted rain events, and BMPs at unmanned facilities must be <br />inspected by the discharger at least once during the rainy season and at least once between each rainy season. <br />For best performance of the DrainPac"I United Storm Water recommends inspections as often as once during the <br />dry season (June-September) and in the wet season (October-May) between or during scheduled cleaning events <br />(depending on actual established schedule). Average number of separate inspections is three per year. Actual <br />scheduling will be based on United recommendations and customer approval based on county stormwater <br />management ordinances and the storm drain flows and loads subjected to the site. Inspection services will ensure <br />that the product is functioning properly and will aid in establishing/changing cleaning schedules accordingly. Any <br />items in need of repaldreplacement should be performed as soon as it is safe to do so. If failure of the product <br />indicates that it is inappropriate or inadequate to the circumstances, the product must be modified or upgraded to <br />prevent any further failure in the same or similar circumstances. <br />Durability <br />The DrainPacTI" is constructed from high quality materials that can withstand normal wear and tear. Any damage <br />that may be caused by fire, sharp objects, vandalism, or other forms of product mistreatment can be repaired by <br />replacing the filter liner and/or support basket as needed utilizing the original frame. The durability of this product <br />will in no way be affected by external factors such as street sweeping and car parking. United Storm Water is not <br />aware of any incidents of vandalism of the product and may be due In part to the need of special tools for removing <br />traffic grates and/or manhole covers in order to access the product. <br />Replacement Parts & Life Expectancy <br />Any damage that may be caused by fire, sharp objects, vandalism, or other forms of product mistreatment can be <br />repaired by replacing the filter liner and/or support basket as needed utilizing the original frame. Not only are our <br />standard rates for new filters economical, yet filter replacements (filter liner and support basket material) that may <br />be required due to normal wear and tare can be provided at 50% of the cost of a same size new DralnPac"". No <br />other replacement parts are required. <br />Life expectancy of the DrainPacTm is dependent on the flows to the site. Average life of a properly maintained unit <br />is three to five years for the filter liner before requiring liner change-out, and the stainless steel frame it reusable for <br />liner replacement which is generally only required due to mishandling/abuse of the product. <br />Warranty Coverage <br />United Storm Water agrees to repair and or replace the frame assembly of this product at no cost to the purchaser <br />for a period of ten (10) years from the date of delivery should failure occur during normal use. The purchaser of <br />this product must be aware that the filter cloth and support basket may become damaged or torn due to retention <br />of items such as sharp objects, corrosives, or enflamed items. Such damage falls outside of the coverage of this <br />p. 5