My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
25I - AGMT - OCWD ASSESSMENT
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2015
>
01/20/2015
>
25I - AGMT - OCWD ASSESSMENT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/15/2015 4:39:07 PM
Creation date
1/15/2015 4:33:26 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Public Works
Item #
25I
Date
1/20/2015
Destruction Year
2020
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
80
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CITY OF SANTA ANA <br />Well No, 32 Mtrate Mitigation and Rehabilitatlon Study <br />A. Nitrate Mitigation Evaluation: We are assuming the following alternatives will be evaluated: <br />No action <br />Blending in the distribution system at the following locations: <br />— Garthe Reservoir <br />— Memory Lane Pressure Reducing Facility (blending Well No. 32 water into the well water <br />from the City's easterly sources) <br />Treatment technologies to reduce the nitrate levels located either on -site at Morrison Park or at <br />Garthe Reservoir. <br />5. Budgetary costs for each of the alternatives shall be prepared. <br />6. Since the well has been out of service for the last five to six years, the City desires to include an <br />estimated cost to rehabilitate the well. <br />7. Pump Design: Tetra Tech will perform an evaluation of the hydraulics and review the existing well <br />pump design and provide a recommendation for the pump design and motor horsepower. Tetra Tech <br />will prepare an engineer's estimate of probable constriction costs for the new well pump and motor. <br />8. Building Modification: Tetra Tech will review the existing underground vault design and then <br />provide a recommendation for modifying the current structure and adding an aboveground building <br />with a stairwell down to the well pump. We are assuming that the new building will be a concrete <br />block building with a gabled roof, similar to other City facilities. <br />9. MCC Replacement: The existing MCC was previously flooded. The new MCC and PLC panels will <br />be located within the proposed building. Tetra Tech will perform a site visit to review the existing <br />panels and instrumentation at the site. <br />RW0597\0086Tngiueering \05\ Welld2-Nitrate- Mitigation \DraRReport\021extdoce 2 - TETRA TECH <br />251 -20 <br />
The URL can be used to link to this page
Your browser does not support the video tag.