My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
75A - PH - RESO - WATER RATES
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2015
>
02/17/2015
>
75A - PH - RESO - WATER RATES
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2015 5:35:38 PM
Creation date
2/12/2015 5:23:40 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Public Works
Item #
75A
Date
2/17/2015
Destruction Year
2020
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
324
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Authorize Staff to Prepare Documents for <br />Proposed Water and Sewer Rate Adjustments <br />December 2, 2014 <br />Page 2 <br />Cag_ital Improvement Program <br />During the review of available asset records and operational data to develop a comprehensive <br />repair and replacement (R &R) program for the City, the following observations were made: <br />Average age of the water and sewer systems is 50 years <br />Life expectancy for water and sewer mains range from 40 to 60 years <br />More than 70% of the water system was installed pre -1980s <br />More than 85% of the sewer system was installed pre -1980s <br />Average age of water pipe breakage is 35 to 45 years <br />• Current replacement rate for water /sewer lines is less than the industry standard of 1% of <br />total system miles per year. <br />A risk -based analysis to determine the risk of failure, the consequence of failure, and a business - <br />risk exposure (BRIE) rating for each asset was conducted. The analyses concluded the following: <br />• Approximately 13 miles of water lines (5% of the system), costing $35.3 million, have a high <br />probability of failure in the next 5 years <br />• Approximately 62 miles of sewer lines (15% of the system), costing $29 million, has a high <br />probability of failure in the next 5 years <br />The proposed Capital Improvement Programs (CIP) for the water and sewer utilities Incorporate <br />the critical R &R projects identified by the risk assessment as well as a ramp -up of annual R &R <br />replacements. (See Exhibit 1, Table 7; and Exhibit 2, Table 8.) <br />The studies also examined the impact to the City in a scenario where CIP activities are deferred. <br />Using a methodology developed by the American Society of Civil Engineers (ASCE), the cost <br />impacts to Santa Ana households, businesses, and local economy were estimated, These <br />potential costs would be in addition to the cost of replacing the asset and possible fines issued by <br />oversight agencies. Included in the projections are Items such as claim payments made for <br />temporary relocation or property damage, impacts to businesses due to main failures /spills, and <br />the economic loss due to lost water supply, loss of jobs, and business closures. (See Exhibit 1, <br />Table ES -3; and Exhibit 2, Table ES -3.) <br />Financial Plan <br />To support the proposed water and sewer CIPs, the financial analysis recommends issuing <br />revenue bonds. For the water CIP, an estimated $24 million in debt financing is needed; for the <br />sewer CIP, the amount is $18.2 million. <br />As part of the analysis, existing reserve levels were examined to determine if changes were <br />required. To maintain the programs on a solid financial footing, It is recommended that the utilities <br />maintain a working capital reserve of 90 days of operations and maintenance plus a $1 million <br />emergency reserve, Staff also recommends that as the CIP backlogs are reduced and the <br />systems regain financial stability, an R &R reserve be established for each utility. Annual funding of <br />the reserves would gradually build to a level equal the depreciation of the system. <br />65B -2 <br />75A -26 <br />
The URL can be used to link to this page
Your browser does not support the video tag.