My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
22B - SPEC - HVAC REPAIR
Clerk
>
Agenda Packets / Staff Reports
>
City Council (2004 - Present)
>
2016
>
03/15/2016
>
22B - SPEC - HVAC REPAIR
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/10/2016 3:30:16 PM
Creation date
3/10/2016 3:25:20 PM
Metadata
Fields
Template:
City Clerk
Doc Type
Agenda Packet
Agency
Finance & Management Services
Item #
22B
Date
3/15/2016
Destruction Year
2021
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
90
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
20. Check and record all entering and leaving water temperatures and pressures as required, <br />21, The equipment room shall be left in the same clean condition as existed prior to start of the work. <br />22. Refer to equipment O &M manual for any maintenance clarifications. <br />Cooling Tower: <br />1. Provide four (4) quarterly inspections and maintenance. <br />2. Preventive maintenance as required. <br />3. Lack -out and Tag -out equipment as required. <br />4. Check starter contacts for excessive wear as needed. <br />5. Tighten all starter wire connections. <br />6. Check gear reducer and couplings. <br />7. Meg -Ohm motor and VFD's. <br />8. Check fan balance and motor(s) amps. <br />9, Clean and lubricate unit motor bearings and fan blades. <br />10. Check operation of media and flow. <br />11. Lubricate all dampers and linkages as necessary. <br />Chilled Water Pumps: <br />1. Check pump and motor operation. <br />2. Check fault history report as required. <br />3. Check and operate bypass valves. <br />4. Checks and verify strainers for optimum flow. <br />5. Check and tighten all electrical connections as required <br />6. Check starter contacts for wear as required. <br />7. Check and record motor amp. <br />8. Lube and grease motor bearings as needed. <br />Johnson Controls: <br />1. Inspect and repair NCU 1 to NCU 12 for optimum operations. <br />2. Inspect and repair as needed 46 air handler controls. <br />3. Inspect all damper motors controls and set points. <br />4. Provide JCI parts as needed. <br />5. Check and calibrate all safety and cut -out devices as required. <br />6. Check and adjust programming as required. <br />7. Inspect Energy Management System (EMS) data base and adjust as needed. <br />Shooting Range: <br />1, Perform annual air balancing per requirements, <br />2. Perform Inspection and maintenance as required. <br />3. Lock -out and Tag -out equipment as required. <br />4. Check fan motor amps as required. <br />5. Clean and lubricate components as required. <br />6. Check operation of economy dampers as required. <br />7. Check operation of static vane or dampers as required. <br />8. Check operation of zone dampers as required. <br />9. Check and adjust operating and safety controls as required. <br />Freezers and /or Refrigerators <br />9, Check all operation, electrical, condensers, evaporators and refrigeration. <br />10. Check starter contactor surfaces for wear as required. <br />11. Check compressor amps and record as required. <br />12. Check sight glass for moisture level as required. <br />Facilities HVAC Service, Maintenance and Repairs 15 -114 <br />Page 15 <br />22B -21 <br />
The URL can be used to link to this page