WINDOW ASSEMBLY <br />MATERIALS REQUIRED PER WINDOW <br />I - 1/2" CDX PLYWOOD SHEET -CUT TO DIMENSIONS OF WINDOW FRAME (WEATHER SIDE <br />4 - 2X4 BRACES - CUT TO WIDTH OF PLYWOOD <br />4 - CARRIAGE BOLT ASSEMBLIES <br />NUMBER OF WINDOWS TO BE SECURED (Nw): <br />NUMBER OF WINDOWS BRACES REQUIRED: (Nw X 4) <br />CARRIAGE BOLT ASSEMBLIES REQUIRED (Bw): (Nw X 4) <br />DOOR ASSEMBLY <br />MATERIALS REQUIRED PER DOOR <br />I - 1/2" CDX PLYWOOD SHEET - CUT TO DIMENSIONS OF DOOR FRAME (WEATHER SIDE) <br />I - 1/2" CDX PLYWOOD SHEET - CUT TO OUTSIDE DIMENSIONS OF DOOR FRAME TRIM <br />(INSIDE) <br />6 - 2X4 BRACES - 3 CUT TO WIDTH OF OUTSIDE PLYWOOD <br />- 3 CUT TO WIDTH OF INSIDE PLYWOOD <br />1 - 2X4 BOTTOM BRACE - CUT TO WIDTH OF DOOR "TRIM DRILLED TO FLOOR (INSIDE) <br />6- CARRIAGE BOLT ASSEMBLIES <br />NUMBER OF DOORS TO BE SECURED (ND): <br />NUMBER OF DOOR BRACES REQUIRED: (NI) X 6) <br />NUMBER OF BOTTOM BRACES REQUIRED: (ND) <br />CARRIAGE BOLT ASSEMBLIES REQUIRED (Big): (Nr) X 6) <br />CARRIAGE BOLT ASSEMBLY <br />MATERIALS REQUIRED PER CARRIAGE BOLT ASSEMBLY <br />I - 3/8" X 12' (OR LONGER IF NECESSARY) CARRIAGE BOLT - COURSE THREAD <br />I - 1/2" USS STANDARD FLAT WASHER (WEATHER SIDE) <br />1 - 3/8" USS STANDARD FLAT WASHER (INSIDE) <br />I - 3/8" CONSTRUCTION GRADE NUT - COURSE THREAD <br />(Bw + BD) <br />TOTAL CARRIAGE BOLT ASSEMBLIES REQUIRED FOR WINDOWS AND DOORS: <br />City of Santa Ana RFP 17-066 <br />Page Al -7 <br />25G-42 <br />