Laserfiche WebLink
MS <br />P <br />AC <br />CB <br />B <br />A <br />A <br />A <br />A <br />A <br />AA <br />A <br />A <br />A <br />A <br />A <br />B B B B <br />B B B B B <br />EV <br />SP <br />SITE PLAN LAYOUT <br />(E) MAIN SERVICE PANEL WITH UTILITY METER <br />(N)PV UTILITY AC DISCONNECT SWITCH <br />(N)ENPHASE IQ COMBINER 4 <br />APPROX 45' AC TRENCHED <br />CONDUIT RUN <br />·ELECTRIC CODE:CEC 2019 <br />·FIRE CODE:CFC 2019 <br />·BUILDING CODE:CBC 2019 <br />·RESIDENTIAL CODE:CRC 2019 <br />APPLICABLE CODES <br />COVER PAGE <br />T-01SCALE:1"=20'-0" <br />POOL <br />PHOTOVOLTAIC ARRAY ON <br />DETACHED NON-HABITABLE <br />STRUCTURE-02 <br />ENGINEERING SCOPE OF WORK <br />1. ILLUMINE INDUSTRIES INC. HAS ONLY PROVIDED DRAFTING SERVICES FOR THE PERMIT DRAWINGS. NO ACTUAL ENGINEERING <br />WORK, ENGINEERING REVIEW OR ENGINEERING. <br />APPROVAL HAS BEEN CONDUCTED BY ILLUMINE INDUSTRIES INC UNLESS NOTED OTHERWISE. <br />2. WHEN A PROFESSIONAL ENGINEER APPROVES AND SEALS THE DESIGN FOR COMPONENTS OF THEIR RESPECTIVE DISCIPLINE <br />(STRUCTURAL/ELECTRICAL) SHOWN ON THESE PERMIT. <br />DRAWINGS, HE/SHE: <br />a. TAKES FULL DIRECT CONTROL OF THE ENGINEERED DESIGN. <br />b. IS GIVEN ACCESS TO PERSONALLY SUPERVISE AND RECTIFY ANY ASPECT OF THE ENGINEERED DESIGN. <br />c. HAS FULLY ACCEPTED RESPONSIBILITY FOR THE ENGINEERED DESIGN. <br />GENERAL SYSTEM INFORMATION: <br />SYSTEM SIZE: <br />8800W DC, 6380W AC, 7928W CEC AC <br />MODULES: <br />(22)HANWHA QCELLS Q.PEAK DUO BLK ML-G10+ <br />400W <br />INVERTER: <br />(22)ENPHASE IQ8PLUS-72-2-US(240V)(SI-1), <br />BRANCH DETAILS: <br />1X12, 1X10 MICRO INVERTER BRANCHES <br />SCOPE OF WORK <br />SHEET CATALOG <br />INDEX NO. DESCRIPTION <br />T-01 COVER PAGE <br />S-01 MOUNTING DETAIL <br />S-02 STRUCTURAL DETAIL <br />E-01 SINGLE LINE DIAGRAM <br />E-02 THREE LINE DIAGRAM <br />E-03 ELECTRICAL CALCULATIONS <br />PL-01 WARNING PLACARDS <br />PL-02 SAFETY PLANS-1 <br />PL-03 SAFETY PLANS-2 <br />SS SPEC SHEET(S) <br />1.MODULES ARE LISTED UNDER UL 1703 AND <br />CONFORM TO THE STANDARDS. <br />2.INVERTERS ARE LISTED UNDER UL 1741 AND <br />CONFORM TO THE STANDARDS. <br />3.DRAWINGS ARE DIAGRAMMATIC, INDICATING <br />GENERAL ARRANGEMENT OF THE PV SYSTEM AND <br />THE ACTUAL SITE CONDITION MIGHT VARY. <br />4.WORKING CLEARANCES AROUND THE NEW PV <br />ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN <br />ACCORDANCE WITH CEC 110.26. <br />5.ALL GROUND WIRING CONNECTED TO THE MAIN <br />SERVICE GROUNDING IN MAIN SERVICE PANEL/ <br />SERVICE EQUIPMENT. <br />6.ALL CONDUCTORS SHALL BE 600V, 75°C <br />STANDARD COPPER UNLESS OTHERWISE NOTED. <br />7.WHEN REQUIRED, A LADDER SHALL BE IN PLACE <br />FOR INSPECTION IN COMPLIANCE WITH OSHA <br />REGULATIONS. <br />8.THE SYSTEM WILL NOT BE INTERCONNECTED BY <br />THE CONTRACTOR UNTIL APPROVAL FROM THE <br />LOCAL JURISDICTION AND/OR THE UTILITY. <br />9.ROOF ACCESS POINT SHALL BE LOCATED IN <br />AREAS THAT DO NOT REQUIRE THE PLACEMENT <br />OF GROUND LADDERS OVER OPENINGS SUCH AS <br />WINDOWS OR DOORS, AND LOCATED AT STRONG <br />POINTS OF BUILDING CONSTRUCTION WHERE THE <br />ACCESS POINT DOES NOT CONFLICT WITH <br />OVERHEAD OBSTRUCTIONS SUCH AS TREES, <br />WIRES OR SIGNS. <br />10.PV ARRAY COMBINER/JUNCTION BOX <br />PROVIDES TRANSITION FROM ARRAY WIRING TO <br />CONDUIT WIRING <br />GENERAL NOTES <br />BEATRICE RAYA - 8.800kW DC, 6.380kW AC, 7.928kW CEC AC VICINITY MAP <br />33.762753, -117.872883 <br />APN: 002-10-305 <br />CUSTOMER INFORMATION <br />NAME:BEATRICE RAYA <br />DATE:7/21/2022 <br />SCALE:AS NOTED REV:D <br />AHJ:CA-CITY OF SANTA ANA <br />UTILITY:SOUTHERN CALIFORNIA EDISON <br />PRN NUMBER:TPS-56928 <br />DRAFTED BY: <br />P.SANKET <br />QC'ED BY: <br />A.N.KRISHNAN <br />PAPER SIZE:17"X11" <br />ADDRESS:2004 N ROSS ST, SANTA ANA, <br />CA 92706 <br />ADDRESS: 525W, BASELINE RD <br />MESA AZ,85210 <br />LICENSE#'S CA:1062072 BL:010238 <br />TSP NUMBER:TSP133481 <br />STRING CONFIGURATION <br />BRANCH DETAILS <br />A 12 MODULES <br />B 10 MODULES <br />FENCE <br />174'-10" <br />174'-10" <br />52' <br />PROPERTY LINE <br />PHOTOVOLTAIC ARRAY ON <br />DETACHED NON-HABITABLE <br />STRUCTURE-01 <br />CONDUIT RUN <br />TOTAL AREA OF ROOF (SQ.FT) 3910 <br />TOTAL ARRAY AREA (SQ.FT) 464.6583 <br />TOTAL AREA OF ARRAY COVERED <br />IN THE ROOF (%)11.88 <br />2'-5" <br />44'-10" <br />20'-1" <br />1'-1" <br />GATE <br />GATE <br />RESIDENCE <br />APPROX 8' AC <br />TRENCHED <br />CONDUIT RUN <br />DRIVE WAY <br />N <br />R <br />O <br />S <br />S <br /> <br />S <br />T <br />WALK <br /> <br />WAY <br />NOTE: PV SYSTEM TO BE INSTALLED ON <br />DETACHED NON-HABITABLE STRUCTURE. <br />DETACHED STRUCTURE-02 <br />DETACHED <br />STRUCTURE-01 <br />(N)EV CHARGER <br />(N) SUB PANEL <br />Structural <br />Only <br />Signed: 11/10/2022 <br />BLDG# 101113123 ISS 12/13/22 ELEC# 20178209 ISS 12/13/22 <br />The scope of the plans is for the installation of the solar photovoltaic system only and the approval is <br />subject to compliance with all applicable city and state codes and regulations regarding construction. The <br />approval of the plans does not constitute any certification of the accuracy, completeness, or building <br />permit status of the existing buildings and structures as shown <br />2004 N Ross St <br />12/14/22