Laserfiche WebLink
MA <br />I <br />N <br /> <br />R <br />E <br />S <br />I <br />D <br />E <br />N <br />C <br />E <br />: <br />25 <br />1 <br />7 <br /> <br />C <br />O <br />T <br />T <br />E <br />R <br /> <br />S <br />T <br />. <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />B <br />A <br />O <br /> <br /> <br />P <br />H <br />A <br />M <br /> <br /> <br />D <br />E <br />S <br />I <br />G <br />N <br /> <br /> <br />O <br />F <br />F <br />I <br />C <br />E <br />LICENSED ARCHITECT <br />STATEOF CALIFORNIA <br />C-39025 <br />REN. 08/31/25 <br />BAO PHAM <br />ARCHITECT OF RECORD: <br />BAO PHAM, RA <br />13 <br />1 <br />0 <br /> <br />N <br /> <br />H <br />A <br />R <br />B <br />O <br />R <br /> <br />B <br />L <br />V <br />D <br />. <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />3 <br /> <br />| <br /> <br /> <br />b <br />a <br />o <br />@ <br />b <br />p <br />d <br />o <br />- <br />a <br />r <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />s <br />. <br />c <br />o <br />m <br /> <br /> <br />| <br /> <br /> <br />7 <br />1 <br />4 <br />. <br />4 <br />5 <br />7 <br />. <br />0 <br />4 <br />3 <br />6 <br />DE <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />ISSUANCE <br />Designed plans and specifications <br />represented by these drawings are <br />properties of BPDO and were <br />developed for use in connection with <br />each particular project. None of these <br />plans and ideas shall be used, <br />duplicated, disclosed, in part or in <br />whole, without written permission of <br />BPDO. <br />2024.06.28 PLANNING SUBMTTAL <br />2024.08.05 CYCLE 1 SUBMITTAL <br />DE <br />T <br />A <br />C <br />H <br />E <br />D <br /> <br />A <br />D <br />U <br />: <br />25 <br />1 <br />5 <br /> <br />C <br />O <br />T <br />T <br />E <br />R <br /> <br />S <br />T <br />. <br /> <br />S <br />A <br />N <br />T <br />A <br /> <br />A <br />N <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />6 <br />GENERAL NOTES <br />G1.0 <br />GENERAL NOTES <br />APPLICABLE CODES. ALL PROJECTS SHALL COMPLY WITH THE <br />2022 CALIFORNIA RESIDENTIAL CODE (CRC) <br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGREEN) <br />2022 CALIFORNIA ELECTRICAL CODE (CEC) <br />2022 CALIFORNIA MECHANICAL CODE (CMC) <br />2022 CALIFORNIA PLUMBING CODE (CPC) <br />2022 CALIFORNIA FIRE CODE (CFC) <br />2022 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS (CBEES) <br />AND ALL APPLICABLE JURISDICTIONAL AMENDMENTS. <br />FOUNDATION AND UNDERFLOOR <br />1. FOUNDATION REINFORCEMENT. CONTINUOUS FOOTINGS AND STEM WALLS SHALL <br />BE PROVIDED WITH A MINIMUM TWO LONGITUDINAL NO. 4 BARS, ONE AT THE TOP <br />AND ONE AT THE BOTTOM OF THE FOOTING. (CRC R403.1.3.3) <br />2. SHEAR WALL FOUNDATION SUPPORT. SHEAR WALLS SHALL BE SUPPORTED BY <br />CONTINUOUS FOUNDATIONS. (CRC 403.1.2) <br />3. CONCRETE SLABS-ON-GRADE. SLABS-ON-GRADE SHALL BE MINIMUM <br />3-1/2-INCHES THICK. (CRC R506.1) <br />4. VAPOR RETARDER. A 6-MIL POLYETHYLENE OR APPROVED VAPOR RETARDER <br />WITH JOINTS LAPPED MINIMUM 6 INCHES SHALL BE PLACED BETWEEN A <br />CONCRETE SLAB-ON-GRADE AND THE BASE COURSE OR SUBGRADE. (CRC 506.2.3) <br />5. ANCHOR BOLTS AND SILLS. FOUNDATION PLATES OR SILLS SHALL BE BOLTED OR <br />ANCHORED TO THE FOUNDATION OR FOUNDATION WALL PER THE FOLLOWING <br />(CRC R403.1.6 AND CRC R602.11.1): <br />a.MINIMUM 1/2-INCH-DIAMETER STEEL BOLTS <br />b.BOLTS EMBEDDED AT LEAST 7 INCHES INTO CONCRETE OR MASONRY <br />c.BOLTS SPACED MAXIMUM 6 FEET ON CENTER <br />d.MINIMUM TWO BOLTS PER PLATE/SILL PIECE WITH ONE BOLT LOCATED MAXIMUM <br />12 INCHES AND MINIMUM 7 BOLT DIAMETERS FROM EACH END OF EACH SILL <br />PLATE/PIECE <br />e.MINIMUM 3-INCH BY 3-INCH BY 0.299-INCH STEEL PLATE WASHER BETWEEN SILL <br />AND NUT ON EACH BOLT <br />6. HOLD-DOWNS. ALL HOLD-DOWNS MUST BE TIED IN PLACE PRIOR TO FOUNDATION <br />INSPECTION. <br />7. PROTECTION OF WOOD AGAINST DECAY. NATURALLY DURABLE OR <br />PRESERVATIVE-TREATED WOOD SHALL BE PROVIDED IN THE FOLLOWING <br />LOCATIONS (CRC R317.1): <br />a.ALL WOOD IN CONTACT WITH GROUND, EMBEDDED IN CONCRETE IN DIRECT <br />CONTACT WITH GROUND, OR EMBEDDED IN CONCRETE EXPOSED TO WEATHER <br />b.WOOD JOISTS WITHIN 18 INCHES AND WOOD GIRDERS WITHIN 12 INCHES OF THE <br />EXPOSED GROUND IN CRAWL SPACES SHALL BE OF NATURALLY DURABLE OR <br />PRESERVATIVE-TREATED WOOD <br />c.WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR <br />FOUNDATION WALLS AND ARE LESS THAN 8 INCHES FROM EXPOSED EARTH <br />SHALL BE OF NATURALLY DURABLE OR PRESERVATIVE-TREATED WOOD <br />d.WOOD FRAMING, SHEATHING, AND SIDING ON THE EXTERIOR OF THE BUILDING <br />AND HAVING CLEARANCE LESS THAN 6 INCHES FROM THE EXPOSED GROUND OR <br />LESS THAN 2 INCHES VERTICALLY FROM CONCRETE STEPS, PORCH SLABS, PATIO <br />SLABS, AND SIMILAR HORIZONTAL SURFACE EXPOSED TO WEATHER <br />e.SILLS AND SLEEPERS ON CONCRETE OR MASONRY SLAB IN DIRECT CONTACT <br />WITH GROUND UNLESS SEPARATED FROM SUCH SLAB BY IMPERVIOUS MOISTURE <br />BARRIER <br />FOUNDATION AND UNDERFLOOR (CONTINUED) <br />f.ENDS OF WOOD GIRDERS ENTERING MASONRY OR CONCRETE WALLS WITH <br />CLEARANCES LESS THAN 1/2 INCH ON TOPS, SIDES, AND ENDS <br />g.WOOD STRUCTURAL MEMBERS SUPPORTING MOISTURE-PERMEABLE FLOORS OR <br />ROOFS EXPOSED TO WEATHER, SUCH AS CONCRETE OR MASONRY SLABS, <br />UNLESS SEPARATED FROM SUCH FLOORS OR ROOFS BY AN IMPERVIOUS <br />MOISTURE BARRIER <br />h.WOOD FURRING STRIPS OR OTHER WOOD FRAMING MEMBERS ATTACHED <br />DIRECTLY TO INTERIOR OF EXTERIOR CONCRETE OR MASONRY WALLS BELOW <br />GRADE EXCEPT WHERE VAPOR RETARDER APPLIED BETWEEN WALL AND <br />FURRING STRIPS OR FRAMING MEMBERS <br />8. UNDERFLOOR VENTILATION. UNDERFLOOR AREAS SHALL HAVE VENTILATION <br />OPENINGS THROUGH FOUNDATION WALLS OR EXTERIOR WALLS, WITH MINIMUM <br />NET AREA OF VENTILATION OPENINGS OF 1 SQUARE FOOT FOR EACH 150 SQUARE <br />FEET OF UNDERFLOOR AREA. ON SUCH VENTILATING OPENING SHALL BE WITHIN 3 <br />FEET OF EACH CORNER OF THE BUILDING. (CRC R408.1) <br />9. UNDERFLOOR ACCESS. UNDERFLOOR AREAS SHALL BE PROVIDED WITH A <br />MINIMUM 18-INCH BY 24-INCH ACCESS OPENING. (CRC R408.4) <br />WOOD FRAMING <br />1. FASTENER REQUIREMENTS. THE NUMBER, SIZE, AND SPACING OF FASTENERS <br />CONNECTING WOOD MEMBERS/ELEMENTS SHALL NOT BE LESS THAN THAT SET FORTH <br />IN CRC TABLE R602.3(1). (CRC R502.9, CRC R602.3, AND CRC R802.2) <br />2. STUD SIZE, HEIGHT, AND SPACING. THE SIZE, HEIGHT, AND SPACING OF STUDS SHALL BE <br />IN ACCORDANCE WITH CRC TABLE R602.3(5). (CRC R602.3.1) <br />3. SILL PLATE. STUDS SHALL HAVE FULL BEARING ON NOMINAL 2-INCH THICK OR LARGER <br />SILL PLATE WITH WIDTH AT LEAST EQUAL TO STUD WIDTH. (CRC R602.3.4) <br />4. BEARING STUDS. WHERE JOISTS, TRUSSES, OR RAFTERS ARE SPACED MORE THAN 16 <br />INCHES ON CENTER AND THE BEARING STUDS BELOW ARE SPACED 24 INCHES ON <br />CENTER, SUCH MEMBERS SHALL BEAR WITHIN 5 INCHES OF THE STUDS BENEATH. (CRC <br />R602.3.3) <br />5. DRILLING AND NOTCHING OF STUDS. ANY STUD IN AN EXTERIOR WALL OR BEARING <br />PARTITION MAY BE CUT OR NOTCHED TO A DEPTH NOT EXCEEDING 25% OF ITS WIDTH. <br />STUDS IN NONBEARING PARTITIONS MAY BE NOTCHED TO A DEPTH NOT TO EXCEED 40% <br />OF A SINGLE STUD WIDTH. ANY STUD MAY BE BORED OR DRILLED, PROVIDED THE <br />DIAMETER OF THE RESULTING HOLE IS NO MORE THAN 60% OF THE STUD WIDTH, THE <br />EDGE OF THE HOLE IS NO MORE THAN 5/8 INCH TO THE EDGE OF THE STUD, AND THE <br />HOLE IS NOT LOCATED IN THE SAME SECTION AS A CUT OR NOTCH. STUDS LOCATED IN <br />EXTERIOR WALL OR BEARING PARTITIONS DRILLED OVER 40% AND UP TO 60% SHALL <br />ALSO BE DOUBLED WITH NO MORE THAN TWO SUCCESSIVE STUDS BORED. (CRC R602.6) <br />6. TOP PLATE. WOOD STUD WALLS SHALL BE CAPPED WITH A DOUBLE TOP PLATE <br />INSTALLED TO PROVIDE OVERLAPPING AT CORNERS AND AT INTERSECTIONS WITH <br />OTHER PARTITIONS. END JOINTS IN DOUBLE TOP PLATES SHALL BE OFFSET AT LEAST 24 <br />INCHES. JOINTS IN PLATES NEED NOT OCCUR OVER STUDS. PLATES SHALL BE MINIMUM <br />NOMINAL 2 INCHES THICK AND HAVE WIDTH AT LEAST EQUAL TO WIDTH OF STUDS. (CRC <br />R602.3.2) <br />7. TOP PLATE SPLICES. TOP PLATE LAP SPLICES SHALL BE FACE-NAILED WITH MINIMUM 8 <br />16D NAILS ON EACH SIDE OF SPLICE. (CRC R602.10.8.1) <br />8. DRILLING AND NOTCHING OF TOP PLATE. WHEN PIPING OR DUCTWORK IS PLACED IN OR <br />PARTLY IN AN EXTERIOR WALL OR INTERIOR LOAD-BEARING WALL, NECESSITATING <br />CUTTING, DRILLING, OR NOTCHING OF THE TOP PLATE BY MORE THAN 50% OF ITS <br />WIDTH, A GALVANIZED METAL TIE NOT LESS THAN 0.054-INCH THICK AND 1-1/2-INCHES <br />WIDE SHALL BE FASTENED ACROSS AND TO THE PLATE AT EACH SIDE OF THE OPENING <br />WITH NOT LESS THAN 8 10D NAILS HAVING A MINIMUM LENGTH OF 1-1/2 INCHES AT EACH <br />SIDE OR EQUIVALENT. THE METAL TIE MUST EXTEND MINIMUM 6 INCHES PAST THE <br />OPENING. (CRC R602.6.1) <br />9. CRIPPLE WALLS. FOUNDATION CRIPPLE WALLS SHALL BE FRAMED OF STUDS NOT LESS <br />IN SIZE THAN THE STUDDING ABOVE. CRIPPLE WALLS MORE THAN 4 FEET IN HEIGHT <br />SHALL HAVE STUDS SIZED AS REQUIRED FOR AN ADDITIONAL STORY. CRIPPLE WALLS <br />WITH STUD HEIGHT LESS THAN 14 INCHES SHALL BE SHEATHED ON AT LEAST ONE SIDE <br />WITH A WOOD STRUCTURAL PANEL FASTENED TO BOTH THE TOP AND BOTTOM PLATES <br />IN ACCORDANCE WITH TABLE R602.3(1), OR THE CRIPPLE WALLS SHALL BE <br />CONSTRUCTED OF SOLID BLOCKING. CRIPPLE WALLS SHALL BE SUPPORTED ON <br />CONTINUOUS FOUNDATIONS. (CRC R602.9) <br />10.WALL BRACING. BUILDINGS SHALL BE BRACED IN ACCORDANCE WITH THE METHODS <br />ALLOWED PER CRC R602.10.2, CRC R602.10.4, AND/OR CRC R602.10.5. <br />11.BRACED WALL LINE SPACING. SPACING BETWEEN BRACED WALL LINES SHALL NOT <br />EXCEED 20 FEET OR ALTERNATE PROVISIONS OF CRC R602.10.1.3. <br />12.SHEAR WALL CUMULATIVE LENGTH. THE CUMULATIVE LENGTH OF SHEAR WALLS WITHIN <br />EACH BRACED WALL LINE SHALL MEET THE PROVISIONS OF CRC TABLE R602.10.3(1) FOR <br />WIND LOADS AND CRC TABLE R602.10.3(2) FOR SEISMIC LOADS. (CRC R602.10.1.1) <br />13.SHEAR WALL SPACING. SHEAR WALLS SHALL BE LOCATED NOT MORE THAN 25 FEET ON <br />CENTER. (CRC R602.10.2.2) <br />14.SHEAR WALL OFFSET. SHEAR WALLS MAY BE OFFSET OUT-OF-PLAN NOT MORE THAN 4 <br />FEET FROM THE DESIGNATED BRACED WALL LINE AND NOT MORE THAN 8 FEET FROM <br />ANY OTHER OFFSET WALL CONSIDERED PART OF THE SAME BRACED WALL LINE. (CRC <br />R602.10.1.2) <br />15.SHEAR WALL LOCATION. SHEAR WALLS SHALL BE LOCATED AT THE ENDS OF EACH <br />BRACED WALL LINE OR MEET THE ALTERNATE PROVISIONS OF CRC R602.10.2.2. <br />16.INDIVIDUAL SHEAR WALL LENGTH. SHEAR WALLS SHALL MEET MINIMUM LENGTH <br />REQUIREMENTS OF CRC R602.10.6.5.1. <br />17.CRIPPLE WALL BRACING. CRIPPLE WALLS SHALL BE BRACED PER CRC R602.10.11. <br />18.SHEAR WALL AND DIAPHRAGM NAILING. ALL SHEAR WALLS, ROOF DIAPHRAGMS, AND <br />FLOOR DIAPHRAGMS SHALL BE NAILED TO SUPPORTING CONSTRUCTION PER CRC <br />TABLE R602.3(1). (CRC R604.3) <br />19.SHEAR WALL JOINTS. ALL VERTICAL JOINTS IN SHEAR WALL SHEATHING SHALL OCCUR <br />OVER, AND BE FASTENED TO, COMMON STUDS. HORIZONTAL JOINTS IN SHEAR WALLS <br />SHALL OCCUR OVER, AND BE FASTENED TO, MINIMUM 1-1/2-INCH-THICK BLOCKING. (CRC <br />R602.10.10) <br />20.FRAMING OVER OPENINGS. HEADERS, DOUBLE JOISTS, OR TRUSSES OF ADEQUATE SIZE <br />TO TRANSFER LOADS TO VERTICAL MEMBERS SHALL BE PROVIDED OVER WINDOW AND <br />DOOR OPENINGS IN LOAD-BEARING WALLS AND PARTITIONS. <br /> (CRC 2304.3.2) <br />21.JOISTS UNDER BEARING PARTITIONS. JOISTS UNDER PARALLEL BEARING PARTITIONS <br />SHALL BE OF ADEQUATE SIZE TO SUPPORT THE LOAD. DOUBLE JOISTS, SIZED TO <br />ADEQUATELY SUPPORT THE LOAD, THAT ARE SEPARATED TO PERMIT THE INSTALLATION <br />OF PIPING OR VENTS SHALL BE FULL-DEPTH SOLID-BLOCKED WITH MINIMUM 2-INCH <br />NOMINAL LUMBER SPACED AT MAXIMUM 4 FEET ON CENTER. BEARING PARTITIONS <br />PERPENDICULAR TO JOISTS SHALL NOT BE OFFSET FROM SUPPORTING GIRDERS, <br />WALLS, OR PARTITIONS MORE THAN THE JOIST DEPTH UNLESS SUCH JOISTS ARE OF <br />SUFFICIENT SIZE TO CARRY THE ADDITIONAL LOAD. (CRC R502.4) <br />22.JOISTS ABOVE OR BELOW SHEAR WALLS. WHERE JOISTS ARE PERPENDICULAR TO A <br />SHEAR WALL ABOVE OR BELOW, A RIM JOIST, BAND JOIST, OR BLOCKING SHALL BE <br />PROVIDED ALONG THE ENTIRE LENGTH OF THE SHEAR WALL. WHERE JOISTS ARE <br />PARALLEL TO A SHEAR WALL ABOVE OR BELOW, A RIM JOIST, END JOIST, OR OTHER <br />PARALLEL FRAMING SHALL BE PROVIDED DIRECTLY ABOVE AND/OR BELOW THE SHEAR <br />WALL. WHERE A PARALLEL FRAMING MEMBER CANNOT BE LOCATED DIRECTLY ABOVE <br />AND/OR BELOW THE SHEAR WALL, FULL-DEPTH BLOCKING AT 16-INCH SPACING SHALL <br />BE PROVIDED BETWEEN THE PARALLEL FRAMING MEMBERS TO EACH SIDE OF THE <br />SHEAR WALL. (CRC R602.10.8) <br />23.FLOOR MEMBER BEARING. THE ENDS OF EACH FLOOR JOIST, BEAM, OR GIRDER SHALL <br />HAVE MINIMUM 1-1/2 INCHES OF BEARING ON WOOD OR METAL AND MINIMUM 3 INCHES <br />OF BEARING ON MASONRY OR CONCRETE EXCEPT WHERE SUPPORTED ON A <br />1-INCH-BY-4-INCH RIBBON STRIP AND NAILED TO THE ADJOINING STUD OR BY THE USE <br />OF APPROVED JOIST HANGERS. (CRC R502.6) <br />24.FLOOR JOIST LAP. FLOOR JOISTS FRAMING OPPOSITE SIDES OVER A BEARING SUPPORT <br />SHALL LAP MINIMUM 3 INCHES AND SHALL BE NAILED TOGETHER WITHIN MINIMUM 3 10D <br />FACE NAILS. A WOOD OR METAL SPLICE WITH STRENGTH EQUAL TO OR GREATER THAN <br />THAT PROVIDED BY THE LAP IS PERMITTED. (CRC R502.6.1) <br />25.FLOOR JOIST-TO-GIRDER SUPPORT. FLOOR JOISTS FRAMING INTO THE SIDE OF A WOOD <br />GIRDER SHALL BE SUPPORTED BY APPROVED FRAMING ANCHORS OR ON LEDGER <br />STRIPS MINIMUM NOMINAL 2 INCHES BY 2 INCHES. (CRC R502.6.2) <br />26.FLOOR JOIST LATERAL RESTRAINT. FLOOR JOISTS SHALL BE SUPPORTED LATERALLY AT <br />ENDS AND EACH INTERMEDIATE SUPPORT BY MINIMUM 2-INCH FULL-DEPTH BLOCKING, <br />BY ATTACHMENT TO FULL-DEPTH HEADER, BAND JOIST, OR RIM JOIST, TO AN ADJOINING <br />STUD, OR SHALL BE OTHERWISE PROVIDED WITH LATERAL SUPPORT TO PREVENT <br />ROTATION. (CRC R502.7) <br />27.FLOOR JOIST BRIDGING. FLOOR JOISTS EXCEEDING NOMINAL 2 INCHES BY 12 INCHES <br />SHALL BE SUPPORTED LATERALLY BY SOLID BLOCKING, DIAGONAL BRIDGING (WOOD OR <br />METAL), OR A CONTINUOUS 1-INCH-BY-3-INCH STRIP NAILED ACROSS THE BOTTOM OF <br />JOISTS PERPENDICULAR TO JOISTS AT MAXIMUM 8-FOOT INTERVALS. (CRC R502.7.1) <br />28.FRAMING OF FLOOR OPENINGS. OPENINGS IN FLOOR FRAMING SHALL BE FRAMED WITH <br />A HEADER AND TRIMMER JOISTS. WHEN THE HEADER JOIST SPAN DOES NOT EXCEED 4 <br />FEET, THE HEADER JOIST MAY BE A SINGLE MEMBER THE SAME SIZE AS THE FLOOR <br />JOIST. SINGLE TRIMMER JOISTS MAY BE USED TO CARRY A SINGLE HEADER JOIST <br />LOCATED WITHIN 3 FEET OF THE TRIMMER JOIST BEARING. WHEN THE HEADER JOIST <br />SPAN EXCEEDS 4 FEET, THE TRIMMER JOISTS AND HEADER JOIST SHALL BE DOUBLED <br />AND OF SUFFICIENT CROSS SECTION TO SUPPORT THE FLOOR JOISTS FRAMING INTO <br />THE HEADER. APPROVED HANGERS SHALL BE USED FOR THE <br />HEADER-JOIST-TO-TRIMMER-JOIST CONNECTIONS WHEN THE HEADER JOIST SPAN <br />EXCEEDS 6 FEET. TAIL JOISTS OVER 12 FEET LONG SHALL BE SUPPORTED AT THE <br />HEADER BY FRAMING ANCHORS OR ON LEDGER STRIPS MINIMUM 2 INCHES BY 2 INCHES. <br />(CRC R502.10) <br />A. WOOD FRAMING (CONTINUED) <br />29.GIRDERS. GIRDERS FOR SINGLE-STORY CONSTRUCTION OR GIRDERS SUPPORTING <br />LOADS FROM A SINGLE FLOOR SHALL NOT BE LESS THAN 4 INCHES BY 6 INCHES FOR <br />SPANS 6 FEET OR LESS, PROVIDED THAT GIRDERS ARE SPACED NOT MORE THAN 8 FEET <br />ON CENTER. OTHER GIRDERS SHALL BE DESIGNED TO SUPPORT THE LOADS SPECIFIED <br />IN THE CBC. GIRDER END JOINTS SHALL OCCUR OVER SUPPORTS. WHEN A GIRDER IS <br />SPLICED OVER A SUPPORT, AN ADEQUATE TIE SHALL BE PROVIDED. THE ENDS OF <br />BEAMS OR GIRDERS SUPPORTED ON MASONRY OR CONCRETE SHALL NOT HAVE LESS <br />THAN 3 INCHES OF BEARING. (CHAPTER 5 CRC) <br />30.RIDGES, HIPS, AND VALLEYS. RAFTERS SHALL BE FRAMED TO A RIDGE BOARD OR TO <br />EACH OTHER WITH A GUSSET PLATE AS A TIE. RIDGE BOARDS SHALL BE MINIMUM <br />1-INCH NOMINAL THICKNESS AND NOT LESS IN DEPTH THAN THE CUT END OF THE <br />RAFTER. AT ALL VALLEY AND HIPS, THERE SHALL BE A VALLEY OR HIP RAFTER NOT <br />LESS THAN 2-INCH NOMINAL THICKNESS AND NOT LESS IN DEPTH THAN THE CUT END OF <br />THE RAFTER. HIP AND VALLEY RAFTERS SHALL BE SUPPORTED AT THE RIDGE BY A <br />BRACE TO A BEARING PARTITION OR BE DESIGNED TO CARRY AND DISTRIBUTE THE <br />SPECIFIC LOAD AT THAT POINT. WHERE THE ROOF PITCH IS LESS THAN 3:12 SLOPE (25% <br />GRADIENT), STRUCTURAL MEMBERS THAT SUPPORT RAFTERS AND CEILINGS JOISTS, <br />SUCH AS RIDGES, HIPS, AND VALLEYS, SHALL BE DESIGNED AS BEAMS. (CRC R802.3) <br />31.CEILING JOIST AND RAFTER CONNECTIONS. CEILING JOISTS AND RAFTERS SHALL BE <br />NAILED TO EACH OTHER PER CRC TABLE R802.5.1(9), AND THE RAFTER SHALL BE NAILED <br />TO THE WALL TOP PLATE PER CRC TABLE R602.3(1). CEILING JOISTS SHALL BE <br />CONTINUOUS OR SECURELY JOINED PER CRC TABLE R802.5.1(9) WHERE THEY MEET <br />OVER INTERIOR PARTITIONS AND ARE NAILED TO ADJACENT RAFTERS TO PROVIDE A <br />CONTINUOUS TIE ACROSS THE BUILDING WHEN SUCH JOISTS ARE PARALLEL TO <br />RAFTERS. WHERE CEILING JOISTS ARE NOT CONNECTED TO THE RAFTERS AT THE <br />WALL TOP PLATE, JOISTS CONNECTED HIGHER IN THE ATTIC SHALL BE INSTALLED AS <br />RAFTER TIES, OR RAFTER TIES SHALL BE INSTALLED TO PROVIDE A CONTINUOUS TIE. <br />WHERE CEILING JOISTS ARE NOT PARALLEL TO RAFTERS, RAFTER TIES SHALL BE <br />INSTALLED. RAFTER TIES SHALL BE MINIMUM 2 INCHES BY 4 INCHES NOMINAL, <br />INSTALLED PER CRC TABLE R802.5.1(9), OR CONNECTIONS OF EQUIVALENT CAPACITIES <br />SHALL BE PROVIDED. WHERE CEILINGS JOISTS OR RAFTER TIES ARE NOT PROVIDED, <br />THE RIDGE FORMED BY THESE RAFTERS SHALL BE SUPPORTED BY A WALL OR <br />ENGINEER-DESIGNED GIRDER. (CRC R802.3.1) <br />32.CEILING JOISTS LAPPED. ENDS OF CEILING JOISTS SHALL BE LAPPED MINIMUM 3 INCHES <br />OR BUTTED OVER BEARING PARTITIONS OR BEAMS AND TOENAILED TO THE BEARING <br />ELEMENT. WHERE CEILING JOISTS PROVIDE RESISTANCE TO RAFTER THRUST, LAPPED <br />JOISTS SHALL BE NAILED TOGETHER PER CRC TABLE R602.3(1) AND BUTTED JOISTS <br />SHALL BE TIED TOGETHER IN A MANNER TO RESIST SUCH THRUST. (CRC R802.3.2) <br />33.COLLAR TIES. COLLAR TIES OR RIDGE STRAPS TO RESIST WIND UPLIFT SHALL BE <br />CONNECTED IN THE UPPER THIRD OF THE ATTIC SPACE. COLLAR TIES SHALL BE A <br />MINIMUM 1 INCH BY 4 INCHES NOMINAL AND SPACED AT MAXIMUM 4 FEET ON CENTER. <br />(CRC R802.3.1) <br />34.PURLINS. PURLINS INSTALLED TO REDUCE THE SPAN OF RAFTERS SHALL BE SIZED NOT <br />LESS THAN THE REQUIRED SIZE OF THE RAFTERS THEY SUPPORT. PURLINS SHALL BE <br />CONTINUOUS AND SHALL BE SUPPORTED BY 2-INCH-BY-4-INCH NOMINAL BRACES <br />INSTALLED TO BEARING WALLS AT A MINIMUM 45-DEGREE SLOPE FROM HORIZONTAL. <br />THE BRACES SHALL BE SPACED MAXIMUM 4 FEET ON CENTER WITH A MAXIMUM 8-FOOT <br />UNBRACED LENGTH. (CRC R802.5.1) <br />35.ROOF/CEILING MEMBER BEARING. THE ENDS OF EACH RAFTER OR CEILING JOIST SHALL <br />HAVE NOT LESS THAN 1-1/2 INCHES OF BEARING ON WOOD OR METAL AND NOT LESS <br />THAN 3 INCHES OF BEARING ON MASONRY OR CONCRETE. (CRC R802.6) <br />36.ROOF/CEILING MEMBER LATERAL SUPPORT. ROOF FRAMING MEMBERS AND CEILING <br />JOISTS WITH A NOMINAL DEPTH-TO-THICKNESS RATIO EXCEEDING 5:1 SHALL BE <br />PROVIDED WITH LATERAL SUPPORT AT POINTS OF BEARING TO PREVENT ROTATION. <br />(CRC R802.8) <br />37.ROOF/CEILING BRIDGING. RAFTERS AND CEILING JOISTS WITH A NOMINAL <br />DEPTH-TO-THICKNESS RATIO EXCEEDING 6:1 SHALL BE SUPPORTED LATERALLY BY <br />SOLID BLOCKING, DIAGONAL BRIDGING (WOOD OR METAL), OR A CONTINUOUS <br />1-INCH-BY-3-INCH WOOD STRIP NAILED ACROSS THE RAFTERS OR CEILING JOISTS AT <br />MAXIMUM 8-FOOT INTERVALS. (CRC R802.8.1) <br />38.FRAMING OF ROOF/CEILING OPENINGS. OPENINGS IN ROOF AND CEILING FRAMING <br />SHALL BE FRAMED WITH A HEADER AND TRIMMER JOISTS. WHEN THE HEADER JOIST <br />SPAN DOES NOT EXCEED 4 FEET, THE HEADER JOIST MAY BE A SINGLE MEMBER THE <br />SAME SIZE AS THE CEILING JOIST OR RAFTER. SINGLE TRIMMER JOISTS MAY BE USED <br />TO CARRY A SINGLE HEADER JOIST LOCATED WITHIN 3 FEET OF THE TRIMMER JOIST <br />BEARING. WHEN THE HEADER JOIST SPAN EXCEEDS 4 FEET, THE TRIMMER JOISTS AND <br />HEADER JOIST SHALL BE DOUBLED AND OF SUFFICIENT CROSS SECTION TO SUPPORT <br />THE CEILING JOISTS OR RAFTERS FRAMING INTO THE HEADER. APPROVED HANGERS <br />SHALL BE USED FOR THE HEADER-JOIST-TO-TRIMMER-JOIST CONNECTIONS WHEN THE <br />HEADER JOIST SPAN EXCEEDS 6 FEET. TAIL JOISTS OVER 12 FEET LONG SHALL BE <br />SUPPORTED AT THE HEADER BY FRAMING ANCHORS OR ON LEDGER STRIPS MINIMUM 2 <br />INCHES BY 2 INCHES. (CRC R502.10) <br />39.ROOF FRAMING ABOVE SHEAR WALLS. RAFTERS OR ROOF TRUSSES SHALL BE <br />CONNECTED TO TOP PLATES OF SHEAR WALLS WITH BLOCKING BETWEEN THE RAFTERS <br />OR TRUSSES. (CRC R602.10.8) <br />40.ROOF DIAPHRAGM UNDER FILL FRAMING. ROOF PLYWOOD SHALL BE CONTINUOUS <br />UNDER CALIFORNIA FILL FRAMING. <br />41.ROOF DIAPHRAGM AT RIDGES. MINIMUM 2-INCH NOMINAL BLOCKING REQUIRED FOR <br />ROOF DIAPHRAGM NAILING AT RIDGES. <br />42.BLOCKING OF ROOF TRUSSES. MINIMUM 2-INCH NOMINAL BLOCKING REQUIRED <br />BETWEEN TRUSSES AT RIDGE LINES AND AT POINTS OF BEARING AT EXTERIOR WALLS. <br />43.TRUSS CLEARANCE. MINIMUM 1/2-INCH CLEARANCE REQUIRED BETWEEN TOP PLATES <br />OF INTERIOR NON-BEARING PARTITIONS AND BOTTOM CHORDS OF TRUSSES. <br />44.DRILLING, CUTTING, AND NOTCHING OF ROOF/FLOOR FRAMING. NOTCHES IN SOLID <br />LUMBER JOISTS, RAFTERS, BLOCKING, AND BEAMS SHALL NOT EXCEED ONE-SIXTH THE <br />MEMBER DEPTH, SHALL BE NOT LONGER THAN ONE-THIRD THE MEMBER DEPTH, AND <br />SHALL NOT BE LOCATED IN THE MIDDLE ONE-THIRD OF THE SPAN. NOTCHES AT <br />MEMBER ENDS SHALL NOT EXCEED ONE-FOURTH THE MEMBER DEPTH. THE TENSION <br />SIDE OF MEMBERS 4 INCHES OR GREATER IN NOMINAL THICKNESS SHALL NOT BE <br />NOTCHED EXCEPT AT MEMBER ENDS. THE DIAMETER OF HOLES BORED OR CUT INTO <br />MEMBERS SHALL NOT EXCEED ONE-THIRD THE MEMBER DEPTH. HOLES SHALL NOT BE <br />CLOSER THAN 2 INCHES TO THE TOP OR BOTTOM OF THE MEMBER OR TO ANY OTHER <br />HOLE LOCATED IN THE MEMBER. WHERE THE MEMBER IS ALSO NOTCHED, THE HOLE <br />SHALL NOT BE CLOSER THAN 2 INCHES TO THE NOTCH. (CRC R502.8.1) <br />45.EXTERIOR LANDINGS, DECKS, BALCONIES, AND STAIRS. SUCH ELEMENTS SHALL BE <br />POSITIVELY ANCHORED TO THE PRIMARY STRUCTURE TO RESIST BOTH VERTICAL AND <br />LATERAL FORCES OR SHALL BE DESIGNED TO BE SELF-SUPPORTING. ATTACHMENT <br />SHALL NOT BE ACCOMPLISHED BY USE OF TOENAILS OR NAILS SUBJECT TO <br />WITHDRAWAL. (CRC R311.3) <br />46.FIREBLOCKING. FIREBLOCKING SHALL BE PROVIDED IN THE FOLLOWING LOCATIONS <br />(CRC R302.11 AND CRC R1003.19): <br />a.IN CONCEALED SPACES OF STUD WALLS AND PARTITIONS, INCLUDING FURRED <br />SPACES, AND PARALLEL ROWS OF STUDS OR STAGGERED STUDS, AS FOLLOWS: <br />i.VERTICALLY AT THE CEILING AND FLOOR LEVELS <br />ii.HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FEET <br />b.AT ALL INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND HORIZONTAL <br />SPACES SUCH AS OCCUR AT SOFFITS, DROP CEILINGS, AND COVE CEILINGS <br />c.IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE <br />RUN <br />d.AT OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES AND WIRES AT CEILING AND <br />FLOOR LEVEL, WITH AN APPROVED MATERIAL TO RESIST THE FREE PASSAGE OF <br />FLAME AND PRODUCTS OF COMBUSTION <br />e.AT CHIMNEYS AND FIREPLACES PER ITEM E.49 <br />f.CORNICES OF A TWO-FAMILY DWELLING AT THE LINE OF DWELLING-UNIT SEPARATION <br />47.FIREBLOCKING MATERIALS. EXCEPT AS OTHERWISE SPECIFIED IN ITEMS E.48 AND E.49, <br />FIREBLOCKING SHALL CONSIST OF THE FOLLOWING MATERIALS WITH THE INTEGRITY <br />MAINTAINED (CRC R302.11.1): <br />a.TWO-INCH NOMINAL LUMBER <br />b.TWO THICKNESSES OF ONE-INCH NOMINAL LUMBER WITH BROKEN LAP JOINTS <br />c.ONE THICKNESS OF 23/32-INCH WOOD STRUCTURAL PANEL WITH JOINTS BACKED BY <br />23/32-INCH WOOD STRUCTURAL PANEL <br />d.ONE THICKNESS OF 3/4-INCH PARTICLEBOARD WITH JOINTS BACKED BY 3/4-INCH <br />PARTICLEBOARD <br />e.1/2-INCH GYPSUM BOARD <br />f.1/4-INCH CEMENT-BASED MILLBOARD <br />g.BATTS OR BLANKETS OF MINERAL OR GLASS FIBER OF OTHER APPROVED MATERIALS <br />INSTALLED IN SUCH A MANNER AS TO BE SECURELY RETAINED IN PLACE. BATTS OR <br />BLANKETS OF MINERAL OR GLASS FIBER OR OTHER APPROVED NON-RIGID MATERIALS <br />SHALL BE PERMITTED FOR COMPLIANCE WITH THE 10-FOOT HORIZONTAL <br />FIREBLOCKING IN WALLS CONSTRUCTED USING PARALLEL ROWS OF STUDS OR <br />STAGGERED STUDS. UNFACED FIBERGLASS BATT INSULATION USED AS FIREBLOCKING <br />SHALL FILL THE ENTIRE CROSS-SECTION OF THE WALL CAVITY TO A MINIMUM HEIGHT <br />OF 16 INCHES MEASURED VERTICALLY. WHEN PIPING, CONDUIT, OR SIMILAR <br />OBSTRUCTIONS ARE ENCOUNTERED, THE INSULATION SHALL BE PACKED TIGHTLY <br />AROUND THE OBSTRUCTION. LOOSE-FILL INSULATION MATERIAL SHALL NOT BE USED <br />AS A FIREBLOCK UNLESS SPECIFICALLY TESTED IN THE FORM AND MANNER INTENDED <br />FOR USE TO DEMONSTRATE ITS ABILITY TO REMAIN IN PLACE AND TO RETARD THE <br />SPREAD OF FIRE AND HOT GASES. <br />48.FIREBLOCKING AT OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES, AND WIRES AT <br />CEILING AND FLOOR LEVEL. SUCH OPENINGS SHALL BE FIREBLOCKED WITH AN <br />APPROVED MATERIAL TO RESIST THE FREE PASSAGE OF FLAME AND PRODUCTS OF <br />COMBUSTION. (CRC R302.11) <br />WOOD FRAMING (CONTINUED) <br />49.FIREBLOCKING OF CHIMNEYS AND FIREPLACES. ALL SPACES BETWEEN CHIMNEYS AND <br />FLOORS AND CEILINGS THROUGH WHICH CHIMNEYS PASS SHALL BE FIREBLOCKED WITH <br />NONCOMBUSTIBLE MATERIAL SECURELY FASTENED IN PLACE. THE FIREBLOCKING OF <br />SPACES BETWEEN CHIMNEYS AND WOOD JOISTS, BEAMS, OR HEADERS SHALL BE <br />SELF-SUPPORTING OR BE PLACED ON STRIPS OF METAL OR METAL LATH LAID ACROSS <br />THE SPACES BETWEEN COMBUSTIBLE MATERIAL AND THE CHIMNEY. (CRC R1003.19) <br />50.DRAFTSTOPPING. IN COMBUSTIBLE CONSTRUCTION WHERE THERE IS USABLE SPACE <br />BOTH ABOVE AND BELOW THE CONCEALED SPACE OF A FLOOR/CEILING ASSEMBLY, <br />DRAFTSTOPS SHALL BE INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE <br />DOES NOT EXCEED 1000 SQUARE FEET. DRAFTSTOPPING SHALL DIVIDE THE <br />CONCEALED SPACE INTO APPROXIMATELY EQUAL AREAS. WHERE THE ASSEMBLY IS <br />ENCLOSED BY A FLOOR MEMBRANE ABOVE AND A CEILING MEMBRANE BELOW, <br />DRAFTSTOPPING SHALL BE PROVIDED IN FLOOR/CEILING ASSEMBLIES UNDER THE <br />FOLLOWING CIRCUMSTANCES (CRC R302.12): <br />a.CEILING IS SUSPENDED UNDER THE FLOOR FRAMING <br />b.FLOOR FRAMING IS CONSTRUCTED OF TRUSS-TYPE OPEN-WEB OR PERFORATED <br />MEMBERS <br />51.DRAFTSTOPPING MATERIALS. DRAFTSTOPPING SHALL NOT BE LESS THAN 1/2-INCH <br />GYPSUM BOARD, 3/8-INCH WOOD STRUCTURAL PANELS, OR OTHER APPROVED <br />MATERIALS ADEQUATELY SUPPORTED. DRAFTSTOPPING SHALL BE INSTALLED <br />PARALLEL TO THE FLOOR FRAMING MEMBERS UNLESS OTHERWISE APPROVED BY THE <br />BUILDING OFFICIAL. THE INTEGRITY OF DRAFTSTOPS SHALL BE MAINTAINED. (CRC <br />R302.12.1) <br />52.COMBUSTIBLE INSULATION CLEARANCE. COMBUSTIBLE INSULATION SHALL BE <br />SEPARATED MINIMUM 3 INCHES FROM RECESSED LUMINAIRES, FAN MOTORS, AND <br />OTHER HEAT-PRODUCING DEVICES. (CRC R302.14) <br />GENERAL MATERIAL SPECIFICATIONS <br />LUMBER. ALL JOISTS, RAFTERS, BEAMS, AND POSTS 2-INCHES TO 4-INCHES THICK <br />SHALL BE NO. 2 GRADE DOUGLAS FIR-LARCH OR BETTER. ALL POSTS AND BEAMS 5 <br />INCHES AND THICKER SHALL BE NO. 1 GRADE DOUGLAS FIR-LARCH OR BETTER. STUDS <br />NOT MORE THAN 8 FEET LONG SHALL BE STUD-GRADE DOUGLAS FIR-LARCH OR <br />BETTER WHEN SUPPORTING NOT MORE THAN ONE FLOOR, ROOF, AND CEILING. STUDS <br />LONGER THAN 8 FEET SHALL BE NO. 2 GRADE DOUGLAS FIR-LARCH OR BETTER. <br />1. CONCRETE. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF <br />3,000 PSI AT 28 DAYS AND SHALL CONSIST OF 1 PART CEMENT, 3 PARTS SAND, 4 <br />PARTS 1-INCH MAXIMUM SIZE ROCK, AND NOT MORE THAN 7-1/2 GALLONS OF <br />WATER PER SACK OF CEMENT. (CRC R402.2) <br />2. MORTAR. MORTAR USED IN CONSTRUCTION OF MASONRY WALLS, FOUNDATION <br />WALLS, AND RETAINING WALLS SHALL CONFORM TO ASTM C 270 AND SHALL <br />CONSIST OF 1 PART PORTLAND CEMENT, 2-1/4 TO 3 PARTS SAND, AND 1/4 TO 1/2 <br />PART HYDRATED LIME. (CRC CHAPTER 4) <br />3. GROUT. GROUT SHALL CONFORM TO ASTM C 476 AND SHALL CONSIST OF 1 PART <br />PORTLAND CEMENT, 1/10 PART HYDRATED LIME, 2-1/4 TO 3 PARTS SAND, AND 1 TO <br />2 PARTS GRAVEL. GROUT SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH OF <br />2,000 PSI AT 28 DAYS. (CRC CHAPTER 4) <br />4. MASONRY. MASONRY UNITS SHALL COMPLY WITH ASTM C 90 FOR LOAD-BEARING <br />CONCRETE MASONRY UNITS. (CRC CHAPTER 4) <br />5. REINFORCING STEEL. REINFORCING STEEL USED IN CONSTRUCTION OF <br />REINFORCED MASONRY OR CONCRETE STRUCTURES SHALL BE DEFORMED AND <br />COMPLY WITH ASTM A 615. (CRC CHAPTER 4) <br />6. STRUCTURAL STEEL. STEEL USED AS STRUCTURAL SHAPES SUCH AS <br />WIDE-FLANGE SECTIONS, CHANNELS, PLATES, AND ANGLES SHALL COMPLY WITH <br />ASTM A36. PIPE COLUMNS SHALL COMPLY WITH ASTM A53. STRUCTURAL TUBES <br />SHALL COMPLY WITH ASTM A500, GRADE B. <br />7. FASTENERS FOR PRESERVATIVE-TREATED WOOD. FASTENERS FOR <br />PRESERVATIVE-TREATED AND FIRE-RETARDANT-TREATED WOOD - INCLUDING <br />NUTS AND WASHERS -- SHALL BE OF HOT DIPPED ZINC-COATED GALVANIZED <br />STEEL, STAINLESS STEEL, SILICON BRONZE, OR COPPER. (CRC R317.3.1) <br />EXCEPTION: 1/2-INCH DIAMETER OR GREATER STEEL BOLTS <br />EXCEPTION: FASTENERS OTHER THAN NAILS AND TIMBER RIVETS MAY BE OF <br />MECHANICALLY DEPOSITED ZINC-COATED STEEL WITH COATING WEIGHTS IN <br />ACCORDANCE WITH ASTM B 695, CLASS 55 MINIMUM <br />EXCEPTION: PLAIN CARBON STEEL FASTENERS ACCEPTABLE IN SBX/DOT AND ZINC <br />BORATE PRESERVATIVE-TREATED WOOD IN AN INTERIOR, DRY ENVIRONMENT <br />8. 9. FASTENERS FOR FIRE-RETARDANT-TREATED WOOD. FASTENERS FOR <br />FIRE-RETARDANT-TREATED WOOD USED IN EXTERIOR APPLICATIONS OR WET OR <br />DAMP LOCATIONS SHALL BE OF HOT DIPPED ZINC-COATED GALVANIZED STEEL, <br />STAINLESS STEEL, SILICON BRONZE, OR COPPER. (CRC R317.3.3) <br />9. <br />ROOFING AND WEATHERPROOFING <br />1. THE ENTIRE ROOF COVERING OF EVERY EXISTING STRUCTURE WHERE MORE <br />THAN 50 PERCENT OF THE TOTAL ROOF AREA IS REPLACED WITHIN ANY ONE-YEAR <br />PERIOD, THE ENTIRE ROOF COVERING OF EVERY NEW STRUCTURE, AND ANY <br />ROOF COVERING APPLIED IN THE ALTERATION, REPAIR OR REPLACEMENT OF THE <br />ROOF OF EVERY EXISTING STRUCTURE, SHALL BE A FIRE-RETARDANT ROOF <br />COVERING THAT IS AT LEAST CLASS C. (CRC R902.1.3) <br />2. ROOF FLASHING. FLASHING SHALL BE INSTALLED AT WALL AND ROOF <br />INTERSECTIONS, AT GUTTERS, WHEREVER THERE IS A CHANGE IN ROOF SLOPE <br />OR DIRECTION, AND AROUND ROOF OPENINGS. WHERE FLASHING IS OF METAL, <br />THE METAL SHALL BE CORROSION-RESISTANT WITH A THICKNESS OF NOT LESS <br />THAN 0.019 INCH (NO. 26 GALVANIZED SHEET). (CRC R903.2.1) <br />3. CRICKETS AND SADDLES. A CRICKET OR SADDLE SHALL BE INSTALLED ON THE <br />RIDGE SIDE OF ANY CHIMNEY OR PENETRATION MORE THAN 30 INCHES WIDE AS <br />MEASURED PERPENDICULAR TO THE SLOPE. CRICKET OR SADDLE COVERING <br />SHALL BE SHEET METAL OR THE SAME MATERIAL AS THE ROOF COVERING. (CRC <br />R903.2.2) <br />4. WATER-RESISTIVE BARRIER. A MINIMUM OF ONE LAYER OF NO. 15 ASPHALT FELT <br />SHALL BE ATTACHED TO STUDS OR SHEATHING OF ALL EXTERIOR WALLS. SUCH <br />FELT OR MATERIAL SHALL BE APPLIED HORIZONTALLY, WITH THE UPPER LAYER <br />LAPPED OVER THE LOWER LAYER MINIMUM 2 INCHES. WHERE JOINTS OCCUR, <br />FELT SHALL BE LAPPED MINIMUM 6 INCHES. THE FELT SHALL BE CONTINUOUS TO <br />THE TOP OF WALLS AND TERMINATED AT PENETRATIONS AND BUILDING <br />APPENDAGES IN A MANNER TO MAINTAIN A WEATHER-RESISTANT EXTERIOR WALL <br />ENVELOPE. (CRC R703.2) <br />5. WALL FLASHING. APPROVED CORROSION-RESISTANT FLASHING SHALL BE APPLIED <br />SHINGLE FASHION AT THE FOLLOWING LOCATIONS TO PREVENT ENTRY OF WATER <br />INTO THE WALL CAVITY OR PENETRATION OF WATER TO THE BUILDING <br />STRUCTURAL FRAMING COMPONENTS (CRC R703.8): <br />a.EXTERIOR DOOR AND WINDOW OPENINGS, EXTENDING TO THE SURFACE OF THE <br />EXTERIOR WALL FINISH OR TO THE WATER-RESISTIVE BARRIER FOR <br />SUBSEQUENT DRAINAGE <br />b.AT THE INTERSECTION OF CHIMNEYS OR OTHER MASONRY CONSTRUCTION WITH <br />FRAME OR STUCCO WALLS, WITH PROJECTING LIPS ON BOTH SIDES UNDER <br />STUCCO COPINGS <br />c.UNDER AND AT THE ENDS OF MASONRY, WOOD, OR METAL COPINGS AND SILLS <br />d.CONTINUOUSLY ABOVE ALL PROJECTING WOOD TRIM <br />e.WHERE EXTERIOR PORCHES, DECKS, OR STAIRS ATTACH TO A WALL OR FLOOR <br />ASSEMBLY OF WOOD-FRAME CONSTRUCTION <br />f.AT WALL AND ROOF INTERSECTIONS <br />g.AT BUILT-IN GUTTERS <br />6. DAMPPROOFING. DAMPPROOFING MATERIALS FOR FOUNDATION WALLS <br />ENCLOSING USABLE SPACE BELOW GRADE SHALL BE INSTALLED ON THE <br />EXTERIOR SURFACE OF THE WALL, AND SHALL EXTEND FROM THE TOP OF THE <br />FOOTING TO FINISHED GRADE. (CRC R406.1) <br />7. WEEP SCREED. A MINIMUM 0.019-INCH (NO. 26 GALVANIZED SHEET GAGE), <br />CORROSION-RESISTANT WEEP SCREED OR PLASTIC WEEP SCREED WITH A <br />MINIMUM VERTICAL ATTACHMENT FLANGE OF 3-1/2 INCHES SHALL BE PROVIDED <br />AT OR BELOW THE FOUNDATION PLATE LINE ON EXTERIOR STUD WALLS IN <br />ACCORDANCE WITH ASTM C 92. THE WEEP SCREED SHALL BE PLACED A MINIMUM <br />4 INCHES ABOVE THE EARTH OR 2 INCHES ABOVE PAVED AREAS AND SHALL BE OF <br />A TYPE ALLOWING TRAPPED WATER TO DRAIN TO THE EXTERIOR OF THE <br />BUILDING. (CRC R703.7.2.1) <br />8. <br />PLUMBING FIXTURES <br />1. PLUMBING FIXTURES TO COMPLY W/ CONSERVATION FLOW RATES:\ <br />SHOWERHEAD - 1.8 GPM @ 80 PSI <br />LAVATORY FAUCETS - 1.2 GPM @ 60 PSI <br />KITCHEN FAUCETS - 1.8 GPM @ 60 PSI <br />WATER CLOSET - 1.28 GPF <br />URINALS - .5 GPF <br />WALL MOUNTED URINALS - .125 GPF <br />MULTIPLE SHOWER HEAD - 2.0 GPM @ 80 PSI <br />FOR ALL COMBINED SHOWERHEAD, LAVATORY FAUCETS IN PUBLIC AREAS - .5 <br />GPM @ 60 PSI METERING FAUCETS - .25 GALLONS PER CYCLE <br />2. GFIC OUTLET IF LESS THAN 6' AWAY FROM WATER, (SINK) <br />3. ALL SHOWER AND TUB-SHOWER SHALL HAVE A PRESSURE BALANCE <br />THERMOSTATIC MIXING VALVE OR A COMBINATION PRESSURE BALANCE <br />THERMOSTATIC MIXING TYPE VALVE <br />4. WALL COVERING SHALL BE CEMENT PLASTER, TILE OR APPROVED EQUAL TO 72" <br />INCHES ABOVE DRAIN AT SHOWERS OR TUBS WITH SHOWER. MATERIALS OTHER <br />THAN STRUCTURAL ELEMENTS SHALL BE MOISTURE RESISTANT. GLASS <br />ENCLOSURE DOORS AND PANELS MUST BE LABELED CATEGORY II SWING DOOR <br />OUTWARD. NET AREA OF SHOWER RECEPTOR SHALL NOT BE LESS THAN 1,024 SQ <br />IN OF FLOOR AREA, AND ENCOMPASS 30" DIA CIRCLE <br />ELECTRICAL/ MECHANICAL <br />1. ELECTRICAL PLAN IS FOR SCHEMATIC LOCATION OF ELECTRICAL OUTLETS AND <br />LIGHT FIXTURES. VERIFY EXACT LOCATIONS W/ OWNER PRIOR TO INSTALLATION. <br />INSTALLATION MUST BE PER 2019 ELECTRICAL CODE <br />2. ALL BRANCH CIRCUIT AND RECEPTACLES OUTLETS IN BEDROOM SHALL BE <br />PROTECTED BY AND ARC-FAULT CIRCUIT-INTERRUPTER 2019 CEC <br />3. CONTRACTOR TO VERIFY LOCATIONS W/ HOME OWNER <br />4. GENERAL LIGHTING IN KITCHEN SHALL HAVE LAMPS W/ AN EFFICACY OF NOT LESS <br />THAN 40 LUMENS PER WATT. GENERAL LIGHTING MUST PROVIDE A SUFFICIENT <br />LIGHT LEVEL FOR BASIC KITCHEN TASKS AND PROVIDE A UNIFORM PATTERN OF <br />ILLUMINATION. THE HIGH-EFFICIENCY LUMINARIES SHALL BE SWITCHED AT AN <br />ENTRANCE TO THE KITCHEN <br />7. EACH ROOM CONTAINING A SHOWER OR BATHTUB SHALL HAVE AT LEAST ONE <br />LUMINARIES W/ LAMP(S) W/ AN EFFICACY OF 40 LUMENS PER WATT OR GREATER IF <br />THERE IS MORE THAN ONE LUMINARIES IN THE ROOM, THE HIGH-EFFICACY <br />LUMINARIES SHALL BE SWITCHED AT AN ENTRANCE OF THE ROOM. <br />8. G.F.C.I PROTECTION FOR RECEPTACLES SERVING WET BAR COUNTERTOP <br />SURFACES AND LOCATED WITHIN 6' OF THE OUTSIDE EDGE OF WET BAR SINK <br />9. BRANCH CIRCUITS THAT SUPPLY 125 - VOLT, SINGLE PHASE, 15-20 AMPERE <br />RECEPTACLES OUTLETS INSTALLED IN DWELLING UNIT BEDROOMS SHALL BE <br />PROTECTED BY AN ARC-FAULT CIRCUIT INTERRUPTER (CEC 210-12) <br />10.PROVIDE 20' UFER GROUND IN FOOTING <br />11.HIGH EFFICACY LUMINAIRES MUST BE PIN BASED <br />12.TRANSFER AIR. VENTILATION AIR SHALL BE PROVIDED DIRECTLY FROM THE <br />OUTDOORS AND NOT AS TRANSFER AIR FROM ADJACENT DWELLING UNITS OR <br />OTHER SPACES, SUCH AS GARAGES, UNCONDITIONED CRAWLSPACES, OR <br />UNCONDITIONED ATTICS. (CBEES 150.0(O)) <br />13.INSTRUCTIONS AND LABELING. VENTILATION SYSTEM CONTROLS SHALL BE LABELED <br />AND THE HOME OWNER SHALL BE PROVIDED WITH INSTRUCTIONS ON HOW TO <br />OPERATE THE SYSTEM. (CBEES 150.0(O)) <br />14.COMBUSTION AND SOLID-FUEL BURNING APPLIANCES. COMBUSTION APPLIANCES <br />SHALL BE PROPERLY VENTED AND AIR SYSTEMS SHALL BE DESIGNED TO PREVENT <br />BACK DRAFTING. (CBEES 150.0(O)) <br />15.GARAGES. THE WALL AND OPENINGS BETWEEN OCCUPIABLE SPACES AND THE <br />GARAGE SHALL BE SEALED. HVAC SYSTEMS THAT INCLUDE AIR HANDLERS OR <br />RETURN DUCTS LOCATED IN GARAGES SHALL HAVE TOTAL AIR LEAKAGE OF NO <br />MORE THAN 6% OF TOTAL FAN FLOW WHEN MEASURED AT 0.1 IN. W.C. USING <br />CALIFORNIA TITLE 24 OR EQUIVALENTS. (CBEES 150.0(O)) <br />16.MINIMUM FILTRATION. MECHANICAL SYSTEMS SUPPLYING AIR TO OCCUPIABLE <br />SPACE THROUGH DUCTWORK SHALL BE PROVIDED WITH A FILTER HAVING A <br />MINIMUM EFFICIENCY OF MERV 6 OR BETTER. (CBEES 150.0(O)) <br />17.AIR INLETS. AIR INLETS (NOT EXHAUST) SHALL BE LOCATED AWAY FROM KNOWN <br />CONTAMINANTS. (CBEES 150.0(O)) <br />18.AIR MOVING EQUIPMENT. AIR MOVING EQUIPMENT USED TO MEET EITHER THE <br />WHOLE-BUILDING VENTILATION REQUIREMENT OR THE LOCAL VENTILATION <br />EXHAUST REQUIREMENT SHALL BE RATED IN TERMS OF AIRFLOW AND SOUND. <br />(CBEES 150.0(O)) <br />a.ALL CONTINUOUSLY OPERATING FANS SHALL BE RATED AT A MAXIMUM OF 1.0 <br />SONE. <br />b.INTERMITTENTLY OPERATED WHOLE-BUILDING VENTILATION FANS SHALL BE <br />RATED AT A MAXIMUM OF 1.0 SONE. <br />c.INTERMITTENTLY OPERATED LOCAL EXHAUST FANS SHALL BE RATED AT MAXIMUM <br />OF 3.0 SONE. <br />d.REMOTELY LOCATED AIR-MOVING EQUIPMENT (MOUNTED OUTSIDE OF HABITABLE <br />SPACES) NEED NOT MEET SOUND REQUIREMENTS IF AT LEAST 4 FEET OF <br />DUCTWORK BETWEEN FAN AND INTAKE GRILL. <br />19.EXTERIOR LIGHTING. ALL PROJECTS SHALL COMPLY WITH LOCAL LIGHTING <br />ORDINANCE. <br />20.GFCI OUTLETS. GROUND FAULT CIRCUIT INTERRUPTER (GFCI) OUTLETS ARE <br />REQUIRED IN BATHROOMS, AT KITCHEN COUNTERTOPS, AT LAUNDRY AND WET BAR <br />SINKS, IN GARAGES, IN CRAWLSPACES, IN UNFINISHED BASEMENTS, AND <br />OUTDOORS. (CEC 210.8) <br />1. AFCI OUTLETS. ELECTRICAL CIRCUITS IN BEDROOMS, LIVING ROOMS, DINING <br />ROOMS, DENS, CLOSETS, HALLWAYS, OR SIMILAR ROOMS MUST BE PROTECTED BY <br />ARC FAULT CIRCUIT INTERRUPTERS (AFCI). (CEC 210.12) <br />2. LUMINAIRE REQUIREMENTS. INSTALLED LUMINAIRES SHALL MEET THE EFFICACY <br />AND FIXTURE REQUIREMENTS OF CBEES 150.0(K). <br />3. SMOKE DETECTORS IN BUILDING REMODELS. SMOKE DETECTORS ARE REQUIRED IN <br />EACH EXISTING SLEEPING ROOM, OUTSIDE EACH SEPARATE SLEEPING AREA IN THE <br />IMMEDIATE VICINITY OF SLEEPING ROOMS, AND ON EACH STORY OF A DWELLING <br />INCLUDING BASEMENTS. BATTERY-OPERATED DETECTORS ARE ACCEPTABLE IN <br />EXISTING AREAS WITH NO CONSTRUCTION TAKING PLACE AND IN ALTERATIONS NOT <br />RESULTING IN REMOVAL OF INTERIOR WALL OR CEILING FINISHES AND WITHOUT <br />ACCESS VIA AN ATTIC, CRAWL SPACE, OR BASEMENT. (CRC R314.3) <br />4. CARBON MONOXIDE DETECTORS IN BUILDING REMODELS. CARBON MONOXIDE <br />DETECTORS ARE REQUIRED OUTSIDE EACH SEPARATE SLEEPING AREA IN THE <br />IMMEDIATE VICINITY OF SLEEPING ROOMS AND ON EACH STORY OF A DWELLING <br />INCLUDING BASEMENTS. BATTERY-OPERATED DETECTORS ARE ACCEPTABLE IN <br />EXISTING AREAS WITH NO CONSTRUCTION TAKING PLACE AND IN ALTERATIONS NOT <br />RESULTING IN REMOVAL OF INTERIOR WALL OR CEILING FINISHES AND WITHOUT <br />ACCESS VIA AN ATTIC, CRAWL SPACE, OR BASEMENT. (CRC R315.3) <br />5. WATER HEATER SEISMIC STRAPPING. MINIMUM TWO 3/4-INCH-BY-24-GAUGE STRAPS <br />REQUIRED AROUND WATER HEATERS, WITH 1/4-INCH-BY-3-INCH LAG BOLTS <br />ATTACHED DIRECTLY TO FRAMING. STRAPS SHALL BE AT POINTS WITHIN UPPER <br />THIRD AND LOWER THIRD OF WATER HEATER VERTICAL DIMENSION. LOWER <br />CONNECTION SHALL OCCUR MINIMUM 4 INCHES ABOVE CONTROLS. (CPC 507.2) <br />6. GAS APPLIANCES IN GARAGES. WATER HEATERS AND HEATING/COOLING <br />EQUIPMENT CAPABLE OF IGNITING FLAMMABLE VAPORS SHALL BE PLACED ON <br />MINIMUM 18-INCH-HIGH PLATFORM UNLESS LISTING REPORT NUMBER PROVIDED <br />SHOWING IGNITION-RESISTANT APPLIANCE. (CPC 507.13 AND CMC 305.1) <br />7. IMPACT PROTECTION OF APPLIANCES. WATER HEATERS AND HEATING/COOLING <br />EQUIPMENT SUBJECT TO VEHICULAR IMPACT SHALL BE PROTECTED BY BOLLARDS <br />OR AN EQUIVALENT MEASURE. (CPC 507.13.1 AND CMC 305.11) <br />8. WATER CLOSET CLEARANCE. MINIMUM 30-INCH-WIDE BY 24-INCH-DEEP CLEARANCE <br />REQUIRED AT FRONT OF WATER CLOSETS. (CPC 402.5) <br />9. SHOWER SIZE. SHOWER COMPARTMENTS SHALL HAVE MINIMUM AREA OF 1024 <br />SQUARE INCHES AND BE ABLE TO ENCOMPASS A 30-INCH-DIAMETER CIRCLE. <br />SHOWER DOORS SHALL HAVE A MINIMUM 22-INCH UNOBSTRUCTED WIDTH. (CPC <br />408.5 AND CPC 408.6) <br />10.FIREPLACE APPLIANCES. FIREPLACES WITH GAS APPLIANCES ARE REQUIRED TO <br />HAVE THE FLUE DAMPER PERMANENTLY FIXED IN THE OPEN POSITION AND <br />FIREPLACES WITH LPG APPLIANCES ARE TO HAVE NO 'PIT' OR 'SUMP' <br />CONFIGURATIONS. (CMC 303.7.1) <br />11.CHIMNEY CLEARANCE. MINIMUM 2-FOOT CHIMNEY CLEARANCE REQUIRED ABOVE <br />BUILDING WITHIN 10-FOOT HORIZONTALLY OF CHIMNEY. THE CHIMNEY SHALL <br />EXTEND MINIMUM 3 FEET ABOVE HIGHEST POINT WHERE CHIMNEY PASSES <br />THROUGH ROOF. (CRC R1003.9) <br />CALGREEN REQUIREMENTS <br />APPLICABILITY. CALGREEN RESIDENTIAL MANDATORY MEASURES SHALL APPLY TO <br />EVERY NEWLY CONSTRUCTED BUILDING OR STRUCTURE AND WITHIN ANY <br />ADDITION OR ALTERATION INCREASING A BUILDING'S CONDITIONED AREA, VOLUME, <br />OR SIZE. (CALGREEN 101.3, CALGREEN 301.1.1) <br />EXCEPTION: ALL RESIDENTIAL BUILDINGS UNDERGOING PERMITTED <br />ALTERATIONS,ADDITIONS, OR IMPROVEMENTS SHALL REPLACE <br />NONCOMPLIANT PLUMBING FIXTURES WITH WATER-CONSERVING PLUMBING <br />FIXTURES PER CALGREEN 301.1.1 AND CALGREEN 4.303.1 <br />1. <br />WOOD FRAMING CONT. <br />2515 & 2517 N <br />Cotter St5/1/2025