PROPERTY DATA
<br />ADDRESS:1511 S. BIRCH ST.
<br />SANTA ANA, CA 92707
<br />APN:013-182-06
<br />LEGAL DESCRIPTION:TRACT NO 531
<br />LOTS 49/50 BLK C
<br />ZONE:R1 (SINGLE FAMILY RESIDENTIAL)
<br />LOT SIZE:6,000 SF
<br />(E) BUILDING AREA: (E) 1-STORY SFR 1,121 SF
<br /> (E) FRONT PORCH 70 SF
<br /> (E) REAR PATIO COVER 148 SF
<br /> (E) GARAGE 373 SF
<br /> (E) PERGOLA -
<br /> (N) GARAGE ADDITION
<br />(TO BE LEGALIZED) 249 SF
<br /> (N) REAR ATTACHED PATIO 160 SF
<br />TOTAL AREA
<br />LOT COVERAGE: 2,121/ 6,000 SF = .35 = 35%
<br />
<br />DWELLING UNITS:2OWNER INFORMATION
<br />OWNER: SILVIA TORRES
<br />ADDRESS: 1511 S. BIRCH ST.
<br />SANTA ANA, CA 92707
<br />PHONE:(714) 925-3782
<br />SCOPE OF WORK
<br />• CONVERT EXISTING DETACHED GARAGE AND
<br />REAR ADDITION INTO AN ADU
<br />• (TOTAL ADU SIZE 622 SF)
<br />• LEGALIZE A (249 SF) ADDITION ATTACHED TO
<br />GARAGE AND CONVERT TO ADU
<br />• LEGALIZE ATTACHED PATIO COVER (172 SF).
<br />• DEMOLISH EXISTING PERGOLA
<br />CONSTRUCTION NOTES
<br />1. CONTRACTOR TO PROVIDE EXTERIOR GLAZED OPENINGS FOR
<br />NATURAL LIGHT EQUAL TO 1/10TH OF THE FLOOR AREA (10 SQ. FT
<br />MIN.) FOR FAMILY ROOM.
<br />2. ALL ADDITIONAL ROOMS SHALL HAVE A MIN. OF 7’-6”CEILING
<br />HEIGHT (PER 2022 CRC)
<br />3. CONTRACTOR TO PROVIDE SMOKE DETECTOR IN EACH SLEEPING
<br />ROOM AND AT A POINT CENTRALLY LOCATED IN THE CORRIDOR OF
<br />AREA GIVING ACCESS TO EACH SEPARATE SLEEPING AREA AND IN
<br />EACH STORY OR BASEMENT AND IF SLEEPING ROOMS ARE AT AN
<br />UPPER LEVEL, PROVIDE A DETECTOR AT THE CEILING OF THE
<br />UPPER LEVEL IN CLOSE PROXIMITY TO THE STAIRWAY IF
<br />APPLICABLE (PER 2022 CRC).
<br />4. MASTER BEDROOM SHALL HAVE AT LEAST ONE OPERABLE
<br />WINDOW OR DOOR APPROVED FROM EMERGENCY ESCAPE OR
<br />RESCUE WHICH SHALL OPEN DIRECTLY ONTO A PUBLIC STREET,
<br />PUBLIC ALLEY, YARD OR EXIT COURT. THE OPENING SHALL
<br />CONFORM TO THE FOLLOWING:
<br />a. MIN AREA = 5.7 SQ FT.
<br />b. 20”MIN WIDTH
<br />c. 24”MIN HEIGHT
<br />d. FINISH SILL AT 44”MAX ABOVE THE FLOOR
<br />e. SECURITY BARS/GRILLES MAY BE INSTALLED IF EQUIPPED WITH
<br />APPROVED RELEASED DEVICES OPERABLE WITHOUT THE USE OF A
<br />KEY OF SPECIAL KNOWLEDGE AND PROVIDED THE BUILDING
<br />EQUIPPED WITH SMOKE DETECTOR (PER 2022 CRC).
<br />5. PER 2022 CRC:
<br />a. NOTCHING OF STUDS IN BEARING PARTITIONS SHALL NOT
<br />EXCEED 25% OF THE WIDTH.
<br />b. NOTCHING OF STUDS IN NONBEARING PARTITIONS SHALL NOT
<br />EXCEED 40% OF THE WIDTH.
<br />c. BORED HOLES IN STUD IN BEARING PARTITIONS SHALL NOT
<br />EXCEED 40% OF THE WIDTH.
<br />d. BORED HOLES IN THE STUDS IN NONBEARING PARTITIONS SHALL
<br />NOT EXCEED 60% OF THE WIDTH (UNLESS THE BORED STUDS ARE
<br />DOUBLE AND NO MORE THAN TWO SUCH SUCCESSIVE DOUBLE
<br />STUDS ARE SO BORED)
<br />e. BORE HOLES MAY NOT BE LOCATED NEARER THAN 5/8”TO THE
<br />EDGE OF THE STUD AND MAY NOT BE LOCATED IN THE SAME
<br />DIRECTION OF THE STUD AS A CUT OR NOTCH.
<br />6. PURLINS SHALL NOT BE SMALLER THAN THE SUPPORTED
<br />RAFTERS. MAX SPAN OF 2X4 AND 2X6 PURLINS IS 4’-0”AND 6’-0”
<br />RESPECTIVELY. STUDS SHALL BE 2X4 MIN. 8-‘0”LONG MAX AND NOT
<br />LESS THAN 45 DEGREES FROM THE HORIZONTAL (PER 2022 CRC).
<br />7. FOR ATTICS WITH A VERTICAL CLEAR HEIGHT OF 30”OR MORE,
<br />PROVIDE A READILY ACCESSIBLE ATTIC ACCESS OPENING IN THE
<br />CEILING. OPENING SHALL BE 22X30 MIN. AND HAVE 30”MIN HEAD
<br />ROOM (PER 2022 CRC).
<br />8. CONTRACTOR TO PROVIDE VENTILATION FOR ATTIC SPACES AND
<br />ENCLOSE RAFTER SPACES. VENTILATION OPENINGS SHALL BE NOT
<br />LESS THAN 1/150 OF THE AREA VENTILATED. OPENINGS MAY BE
<br />REDUCED TO 1/300 IF 50% OF THE OPENING ARE IN THE UPPER
<br />PORTION OF THE SPACE AND AT LEAST 3’-0”ABOVE THE EAVES.
<br />CORROSION RESISTANT MESH WITH ¼”MAX OPENING IS REQUIRED
<br />(PER 2022 CRC).
<br />9. IN ACCORDANCE WITH THE 2022 CALIFORNIA GREEN BUILDING
<br />STANDARDS CODE AND CALIFORNIA CIVIL CODE SECTION 1101.1;
<br />ALL EXISTING RESIDENTIAL BUILDINGS UNDERGOING PERMITTED
<br />ALTERATION, ADDITIONS, OR IMPROVEMENTS SHALL REPLACE ALL
<br />NON-COMPLIANT PLUMBING FIXTURES WITH WATER CONSERVING
<br />PLUMBING FIXTURES PRIOR TO ANY PERMIT FINAL APPROVALS OR
<br />THE ISSUANCE OF CERTIFICATE OF OCCUPANCY UNLESS NOTED
<br />OTHERWISE.
<br />10. WHERE THE PERMIT IS REQUIRED FOR ALTERATION, REPAIRS
<br />OR ADDITIONS EXCEEDING $1,000 EXISTING DWELLING THAT HAVE
<br />ATTACHED GARAGES OF FUEL-BURNING APPLIANCES SHALL BE
<br />PROVIDE WITH CARBON MONOXIDE ALARM(S) IN ACCORDANCE
<br />WITH CRC 315.1 EXCEPTIONS: HARD WIRING WITH BATTERY BACKUP
<br />INTERCONNECTION IS NOT REQUIRED WITHIN EXISTING DWELLING
<br />UNITS WHERE THERE IS NO COMMERCIAL POWER SUPPLY OR ANY
<br />ALTERATION OR REPAIRS DOES NOT RESULT IN THE REMOVAL OF
<br />WALL AND CEILING FINISHES OR THERE IS NO ACCESS BY MEANS OF
<br />ATTIC; BASEMENT OR CRAWL SPACE.
<br />11. WHERE ALTERATIONS, REPAIR OR ADDITIONS REQUIRING A
<br />PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE
<br />ADDED OR CREATED IN EXISTING DWELLING, SMOKE ALARMS
<br />LISTED IN ACCORDANCE WITH UL 217 SHALL BE INSTALLED A
<br />REQUIRED FOR NEW CONSTRUCTION. R314.3.1 EXCEPTION: HARD
<br />WIRING WITH BATTERY BACKUP AND INTERCONNECTIONS IS NOT
<br />REQUIRED WITHIN EXISTING DWELLING UNITS WHERE THERE IS NO
<br />COMMERCIAL POWER SUPPLY OR ANY ALTERATION OR REPAIR
<br />DOES NOT RESULT IN THE REMOVAL OF WALL AND CEILING
<br />FINISHES OR THERE IS NO ACCESS BY MEAN OF ATTIC; BASEMENT
<br />OR CRAWL SPACE.
<br />12. ALL OUTLETS INSTALLED IN DWELLING UNIT BEDROOMS, FAMILY
<br />ROOMS, DINING ROMS, LIVING ROOMS, PARLORS, DENS, LIBRARIES,
<br />SUN ROOMS, RECREATIONS ROOMS, CLOSETS, HALLWAYS, OR
<br />SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED
<br />“COMBINES TYPE”ARC-FAULT CIRCUIT INTERRUPTED, INSTALLED TO
<br />PROVIDE PROTECTION OF BRANCH CIRCUIT. 2022 CEC, 210.12(B).
<br />13. IN ALL AREAS SPECIFIED IN CEC 210.52, ALL NEW 15 AND 20
<br />AMPERE DWELLING UNIT RECEPTACLES SHALL BE LISTED TAMPER
<br />RESISTANT RECEPTACLES. 2022 CEC 406.12
<br />14. SEC 903.2.1 CRC ROOF FLASHING SHALL BE INSTALLED IN
<br />ACCORDANCE WITH THIS CODE AT ALL WALL AND ROOF
<br />INTERSECTIONS, WHEREVER THERE IS A CHANGE IN ROOF SLOPE
<br />OR DIRECTION AND AROUND ALL ROOF OPENINGS AND
<br />PENETRATIONS, ALL METAL FLASHING SHALL BE CORROSION
<br />RESISTANT WITH THICKNESS OF NOT LESS THAN (0.019) INCHES (NO.
<br />26 GAGE GALVANIZED SHEET METAL.
<br />15. A RADIANT BARRIER IS REQUIRED (FOR CLIMATE ZONES 2-15).
<br />RADIANT BARRIERS SHALL MEET SPECIFIC ELIGIBILITY AND
<br />INSTALLATION CRITERIA TO RECEIVE ENERGY CREDIT FOR
<br />COMPLIANCE WITH THE BUILDING ENERGY EFFICIENCY STANDARDS
<br />FOR LOW-RISE RESIDENTIAL BUILDING. REFER TO RA4.2.1 THE
<br />EMITTANCE OF THE RADIANT BARRIER SHALL BE LESS THAN OR
<br />EQUAL TO 0.05 AS TESTED IN ACCORDANCE WITH ASTM C1371 OR
<br />ASTM E408. FOR PRESCRIPTIVE COMPLIANCE, THE ATTIC SHALL BE
<br />VENTILATED TO PROVIDE A MINIMUM FREE VENTILATION AREA OF
<br />NOT LESS THAN ONE SQ. FT. OF VENT AREA FOR EACH 300 SQ. FT.
<br />OF ATTIC FLOOR ARE WITH NO LESS THAN 30% UPPER VENT. RIDGE
<br />VENTS OR GABLE END VENTS ARE RECOMMENDED TO ACHIEVE THE
<br />BEST PERFORMANCE. THE MATERIAL SHOULD BE CUT TO ALLOW
<br />FOR FULL AIRFLOW TO THE VENTING.
<br />SITE PLAN LEGEND
<br />PROPERTY LINE (E) STRUCTURE
<br />(E) STRUCTURE TO BE MODIFIEDCMU WALL W/
<br />FENCE ABOVE
<br />6'-0" DECORATIVE
<br />IRON FENCE
<br />CMU BLOCK WALL
<br />VINYL FENCE
<br />(N) ADDITION
<br />SHEET FLOW @ MIN. 2% SLOPE
<br />SHEET FLOW NOTE:
<br />IMPERVIOUS IMPERVIOUS SURFACE SHALL BE SLOPED AWAY FROM THE BUILDING AT
<br />2% MINIMUM SLOPE FOR A MINIMUM DISTANCE OF 10 FEET; LOT SHALL BE GRADED TO
<br />DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS; GRADE SHALL FALL 6”
<br />MINIMUM WITHIN THE FIRST 10 FT. –PER SECTION R401.3
<br />CONSULTANTS
<br />STRUCTURAL ENGINEERING:
<br />FRANCISCO GARCIA, P.E.
<br />FJ ENGINEERING+DESIGN
<br />600 W. MAIN ST. SUITE 207
<br />ALHAMBRA, CA 91801
<br />(626)548-3874
<br />MECHANICAL ENGINEERING:
<br />LAWRENCE GORDON
<br />LRG DESIGNS
<br />P.O. BOX 47478
<br />LOS ANGELES, CA 90047
<br />(323)955-9827
<br />DEFFERED SUBMITTALS
<br />• N/A
<br />UNDERGROUND SLEEVING
<br />FOR GAS LINE
<br />1. CONDUIT SHALL BE SOLID AND NON-METALIC FOR 1-INCH THROUGH
<br />4-INCH SIZE.
<br />2. CONDUIT MUST BE A CONTINUOUS LENGTH, AND BENDS MUST BE
<br />GRADUAL.
<br />3. IF INSTALLED IN SAME TRENCH AS ELECTRICAL LINES, CONDUITS
<br />MUST HAVE A MINIMUM SEPARATION EITHER VERTICALLY OR
<br />HORIZONTALLY OF 12 INCHES.
<br />4. MINIMUM DEPTH SHALL BE 24 INCHES FROM FINAL GRADE.
<br />5. CONDUIT SIZE SHALL BE AS FOLLOWS:
<br />6. THE ENDS OF THE CONDUIT SHALL BE SEALED TO PREVENT ENTRY
<br />OF SOIL OR WATER.
<br />7. CONDUIT SHALL BE TAG "GAS" UNDERGROUND.
<br />GAS SERVICE SIZE (INCHES)
<br />5/8"
<br />1-1/8"
<br />1-1/4"
<br />2"
<br />CONDUIT SIZE (INCHES)
<br />1" SOLID / NON-METALLIC
<br />2" SOLID / NON-METALLIC
<br />3" SOLID / NON-METALLIC
<br />4" SOLID / NON-METALLIC
<br />UNDERGROUND GAS-LINE LEGEND
<br />(E) CONC. DRIVEWAY
<br />(E) SINGLE-
<br />FAMILY
<br />RESIDENCE
<br />(1121 SF)
<br />(E) FRONT
<br />PORCH
<br />(E) CANOPY TO
<br />BE REMOVED
<br />AND REBUILT.
<br />(E) LANDSCAPE
<br />(E) POOL
<br />NOT A PART
<br />G
<br />(E) GAS
<br />METER
<br />(E) MAIN
<br />ELEC.
<br />PANEL
<br />BIRCH ST.
<br />(E) 3/4" WATER
<br />METER (V.I.F.)
<br />w (E) PARKWAY
<br />(E) SIDEWALK
<br />50'-0"
<br />12
<br />0
<br />'
<br />-
<br />0
<br />"
<br />6'
<br />-
<br />0
<br />"
<br />4'
<br />-
<br />0
<br />"
<br />20'-0"
<br />(E) REAR
<br />PATIO COVER
<br />(N) ADDITION
<br />(TO BE LEGALIZED)
<br />(249 SF)
<br />(E) PERGOLA
<br />TO BE REMOVED
<br />(E) CONC.
<br />PAVING
<br />(E) ELECT.
<br />SUBPANEL
<br />3'-2"
<br />TO BE
<br />PARTIALLY
<br />DEMO.
<br />5'
<br />-
<br />0
<br />"
<br />18
<br />'
<br />-
<br />8
<br />"
<br />4'-0"
<br />ADDRESS: 1511
<br />(E) GARAGE
<br />TO BE CONVERTED
<br />TO AN ADU
<br />(373 SF)
<br />TOTAL ADU SIZE
<br />622 SF
<br />(E) FENCE
<br />(E) GATE W/ ALARM
<br />DROWNING
<br />PREVENTION ITEMS:
<br />(E) FENCE & ALARM
<br />1'-0"
<br />(E) CONC. DRIVEWAY
<br />(E) POOL
<br />G
<br />BIRCH ST.
<br />(E) 3/4" WATER
<br />METER (V.I.F.)
<br />w (E) PARKWAY
<br />(E) SIDEWALK
<br />50'-0"
<br />12
<br />0
<br />'
<br />-
<br />0
<br />"
<br />(E) CONC.
<br />PAVING
<br />6'
<br />-
<br />0
<br />"
<br />4'
<br />-
<br />0
<br />"
<br />20'-0"
<br />6'
<br />-
<br />0
<br />"
<br />(E) SINGLE-FAMILY
<br />RESIDENCE
<br />(1121 SF)
<br />(E) FRONT
<br />PORCH
<br />NOT A PART
<br />(E) MAIN
<br />ELEC.
<br />PANEL
<br />(E) REAR PATIO COVER
<br />(N) PATIO COVER
<br />(N) ADDITION
<br />(TO BE LEGALIZED)
<br />(249 SF)
<br />(E) GARAGE
<br />TO BE CONVERTED
<br />TO AN ADU
<br />(373 SF)
<br />(E) ELECT.
<br />SUBPANEL
<br />(E) LANDSCAPE
<br />(E) GAS
<br />METER
<br />(E) FENCECLR.
<br />5'-0"
<br />13'-9"
<br />11
<br />'
<br />-
<br />8
<br />"
<br />@
<br />W
<br />A
<br />L
<br />L
<br />(E
<br />)
<br />
<br />5
<br />'
<br />-
<br />0
<br />"
<br />@
<br />R
<br />O
<br />O
<br />F
<br />(E
<br />)
<br />
<br />3
<br />'
<br />-
<br />9
<br />"
<br />@ ROOF/WALL
<br />4'-0"
<br />18
<br />'
<br />-
<br />7
<br />"
<br />13'-4 1/2"
<br />SL
<br />O
<br />P
<br />E
<br />1511 S. BIRCH STREET
<br />SANTA ANA, CA 90727
<br />1513 S. BIRCH STREET
<br />SANTA ANA, CA 90727
<br />(E) GATE W/ ALARM
<br />DROWNING
<br />PREVENTION ITEMS:
<br />(E) FENCE & ALARM
<br />TOTAL ADU SIZE
<br />622 SF
<br />1'-0"
<br />ISSUED
<br />DATE:
<br />REVISIONS
<br />DRAWINGS, SPECIFICATIONS AND OTHER VISUAL AIDS, AS
<br />INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE
<br />DRAFTER/DESIGNER WHETHER THE PROJECT FOR
<br />WHICH THEY ARE MADE BE EXECUTED OR NOT, AND
<br />THEY ARE NOT TO BE USED FOR ANY OTHER SITE THAN
<br />THE ONE FOR WHICH THEY ARE PREPARED, EXCEPT BY
<br />AGREEMENT IN WRITING.
<br />NO
<br />.
<br />
<br />D
<br />E
<br />S
<br />C
<br />R
<br />I
<br />P
<br />T
<br />I
<br />O
<br />N
<br />
<br />D
<br />A
<br />T
<br />E
<br />DRAFTER/DESIGNER:
<br />LUIS N OROZCO
<br />562.661.9281
<br />LUIS.OROZCO.A@LIVE.COM
<br />DATE:
<br />11/19/2024
<br />G101
<br />COVER SHEET
<br />PR
<br />O
<br />P
<br />E
<br />R
<br />T
<br />Y
<br />
<br />O
<br />W
<br />N
<br />E
<br />R
<br />:
<br />
<br />S
<br />I
<br />L
<br />V
<br />I
<br />A
<br />
<br />T
<br />O
<br />R
<br />R
<br />E
<br />S
<br />15
<br />1
<br />1
<br />
<br />S
<br />.
<br />
<br />B
<br />I
<br />R
<br />C
<br />H
<br />
<br />S
<br />T
<br />.
<br />SA
<br />N
<br />T
<br />A
<br />
<br />A
<br />N
<br />A
<br />,
<br />
<br />C
<br />A
<br />
<br />9
<br />0
<br />7
<br />2
<br />7
<br />GA
<br />R
<br />A
<br />G
<br />E
<br />
<br />C
<br />O
<br />N
<br />V
<br />E
<br />R
<br />S
<br />I
<br />O
<br />N
<br />
<br />T
<br />O
<br />
<br />A
<br />N
<br />AC
<br />C
<br />E
<br />S
<br />S
<br />O
<br />R
<br />Y
<br />
<br />D
<br />W
<br />E
<br />L
<br />L
<br />I
<br />N
<br />G
<br />
<br />U
<br />N
<br />I
<br />T
<br />09/10/2024
<br />SHEET INDEXADU -GARAGE CONVERSION
<br />1511 S. BIRCH ST., SANTA ANA, CA 90727 -SFR
<br />APPLICABLE CODES
<br />THIS PROJECT SHALL COMPLY WITH THE FOLLOWING:
<br />2022 CALIFORNIA BUILDING CODE -TITLE 24, PART 2
<br />2022 CALIFORNIA RESIDENTIAL CODE -TITLE 24, PART 2.5
<br />2022 CALIFORNIA MECHANICAL CODE -TITLE 24, PART 4
<br />2022 CALIFORNIA PLUMBING CODE -TITLE 24, PART 5
<br />2022 CALIFORNIA ELECTRICAL CODE -TITLE 24, PART 3
<br />2022 CALIFORNIA ENERGY CODE -TITLE 24, PART 6
<br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE -
<br />TITLE 24, PART 11
<br />2022 ORANGE COUNTY FIRE CODE
<br />CITY OF SANTA ANA REGULATIONS AND ORDINANCES
<br />BUILDING DATA
<br />CONSTRUCTION TYPE: V-B -RESIDENTIAL PRESCRIPTIVE WOOD
<br />NUMBER OF STORIES/ HEIGHT: ONE STORY
<br />FIRE SPRINKLER SYSTEM: NONE EXISTING/ NONE REQUIRED
<br />BASEMENT: NO
<br />TYPE OF ROOF: ASPHALT COMPOSITION SHINGLES
<br />OCCUPANCY LOADS:
<br />ADU: R-3 OCCUPANCY (200 OCCUPANT LOAD) = 373/200= 2 OCCUPANTS
<br />CAL. GREEN BLDG.
<br />STANDARDS
<br />1. ALL FINISH MATERIALS, SUCH AS ADHESIVES, SEALANTS,
<br />CAULKS, PAINTS, AEROSOLS PAINTS, COATING, CARPET
<br />SYSTEMS, RESILIENT FLOORING SYSTEMS AND COMPOSITE
<br />WOOD PRODUCTS SHALL CONFORM TO THE VOC. AND
<br />FORMALDEHYDE LIMITS SET FORTH IN SECTION 4.504.2. 4.504.3,
<br />4.504.4, 4.504.5 AND TABLE 4.504.1, 4.504.2, 4.504.3 AND 4.504.5
<br />(4.405.2 CGBSC)
<br />2. BATHROOM EXHAUST FANS, A ROOM WHICH CONTAINS A
<br />BATHTUB, SHOWER OR TUB/SHOWER COMBINATION, SHALL
<br />COMPLY WITH THE FOLLOWING. PROVIDE NOTES ON THE PLANS.
<br />(4.506.1 CGBSC)
<br />A) FANS SHALL BE ENERGY STAR COMPLIANT AND BE
<br />DUCTED TO TERMINATE OUTSIDE THE BUILDING.
<br />B) UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE
<br />HOUSE VENTILATION SYSTEM, THE FAN MUST BE
<br />CONTROLLED BY A HUMIDISTAT WHICH SHALL BE
<br />READILY ACCESSIBLE. HUMIDISTAT CONTROLS SHALL BE
<br />CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE
<br />HUMIDITY RANGE OF 50 TO 80%. A HUMIDITY CONTROL
<br />MAY BE A SEPARATE COMPONENT TO AN EXHAUST FAN
<br />AND IS NOT REQUIRED TO BE INTEGRAL (I.E. BUILT-IN).
<br />ASSESSOR'S MAP VICINITY MAP
<br />NORTH
<br />01 - GENERAL
<br />G101 COVER SHEET
<br />G102 GENERAL NOTES
<br />G103 GENERAL NOTES
<br />G104 CALGREEN RESIDENTIAL MANDATORY MEASURES
<br />G105 CALGREEN RESIDENTIAL MANDATORY MEASURES
<br />02 - ARCHITECTURAL
<br />A101 FLOOR PLANS
<br />A102 REFLECTED CEILING PLAN & ROOF PLAN
<br />A201 EXTERIOR ELEVATIONS
<br />A301 ENLARGED FLOOR PLANS & INTERIOR ELEVATIONS
<br />A401 WALL SECTIONS
<br />A501 DETAILS - CONSTRUCTION
<br />A502 DETAILS - CONSTRUCTION
<br />A503 DETAILS - TYP. CONSTRUCTION
<br />A601 SCHEDULES
<br />STRUCTURAL
<br />S-0 STRUCTURAL NOTES & SCHEDULES
<br />S-1 FOUNDATION PLA
<br />S-2 CEILING AND ROOF FRAMING PLANS
<br />SD-1 STRUCTURAL DETAILS
<br />T24 / CALGREEN
<br />T24 1 CERTIFICATE OF COMPLIANCE FORMS
<br />T24 2 CERTIFICATE OF COMPLIANCE FORMS
<br />T24 3 RESIDENTIAL MEASURES SUMMARY
<br />GRAND TOTAL: 21 1
<br />P
<br />L
<br />A
<br />N
<br />N
<br />I
<br />N
<br />G
<br />
<br />1
<br />S
<br />T
<br />
<br />P
<br />C
<br />
<br />R
<br />E
<br />S
<br />U
<br />B
<br />M
<br />I
<br />T
<br />T
<br />A
<br />L
<br />
<br />1
<br />0
<br />/
<br />2
<br />3
<br />/
<br />2
<br />0
<br />2
<br />4
<br />2
<br />B
<br />U
<br />I
<br />L
<br />D
<br />I
<br />N
<br />G
<br />
<br />S
<br />U
<br />B
<br />M
<br />I
<br />T
<br />T
<br />A
<br />L
<br />
<br />1
<br />1
<br />/
<br />1
<br />9
<br />/
<br />2
<br />0
<br />2
<br />4
<br />Scale:3/32" = 1'-0"1 SP - EXISTING
<br />Scale:3/32" = 1'-0"2 SP - PROPOSED
<br />NORTH NOTES:
<br />-ALL UTILITY CABLES OR WIRES
<br />BETWEEN THE PRIMARY RESIDENCE
<br />AND THE DETACHED ADU SHALL BE
<br />PLACED UNDERGROUND PER
<br />SECTION 41-626 OF THE SAMC
<br />-NO EASEMENTS LOCATED ON
<br />PROPERTY
<br />1513 S. BIRCH ST., SANTA ANA, CA 90727 -ADU
<br />ADU / SFD = 622 SF/ 1121 SF = .55%
<br />THE ADU/SFD RATIO IS FOR PARK & REC FEE PURPOSE
<br />ONLY. THE APPLICANT IS RESPONSIBLE FOR THE GIVEN
<br />SFR PERCENTAGE OF THE EXISTING PRIMARY
<br />RESIDENCE; BUILDING SAFETY STAFF ARE NOT
<br />RESPONSIBLE FOR THE ACCURACY OF THE GIVEN SFR
<br />SF.
<br />MECHANICAL, ELECTRICAL AND PLUMBING ARE NOT
<br />PART OF THIS PLAN REVIEW AND APPROVAL. THE
<br />BUILDING AND SAFETY DIVISION PLAN REVIEW DOES NOT
<br />INCLUDE POTENTIAL ELECTRICAL, WATER, OR GAS
<br />REVISIONS REQUIRED BY ANY NON-CITY UTILITY
<br />COMPANY. IT IS SOLELY ON THE CONTRACTOR TO
<br />ENSURE PROPOSED ADDITION OR ALTERATION CAN AND
<br />WILL MEET UTILITY COMPANY REQUIREMENTS. MEP ARE
<br />SUBJECT TO BUILDING FIELD INSPECTION.
<br />Bldg #102122347
<br />APPROVALS:
<br />PLNG - C. Santana
<br />BLDG - J, Lo
<br />POLICE - B. Martin
<br />PUBLIC WORKS - Y. Soto
|