PROPERTY DATA <br />ADDRESS:1511 S. BIRCH ST. <br />SANTA ANA, CA 92707 <br />APN:013-182-06 <br />LEGAL DESCRIPTION:TRACT NO 531 <br />LOTS 49/50 BLK C <br />ZONE:R1 (SINGLE FAMILY RESIDENTIAL) <br />LOT SIZE:6,000 SF <br />(E) BUILDING AREA: (E) 1-STORY SFR 1,121 SF <br /> (E) FRONT PORCH 70 SF <br /> (E) REAR PATIO COVER 148 SF <br /> (E) GARAGE 373 SF <br /> (E) PERGOLA - <br /> (N) GARAGE ADDITION <br />(TO BE LEGALIZED) 249 SF <br /> (N) REAR ATTACHED PATIO 160 SF <br />TOTAL AREA <br />LOT COVERAGE: 2,121/ 6,000 SF = .35 = 35% <br /> <br />DWELLING UNITS:2OWNER INFORMATION <br />OWNER: SILVIA TORRES <br />ADDRESS: 1511 S. BIRCH ST. <br />SANTA ANA, CA 92707 <br />PHONE:(714) 925-3782 <br />SCOPE OF WORK <br />• CONVERT EXISTING DETACHED GARAGE AND <br />REAR ADDITION INTO AN ADU <br />• (TOTAL ADU SIZE 622 SF) <br />• LEGALIZE A (249 SF) ADDITION ATTACHED TO <br />GARAGE AND CONVERT TO ADU <br />• LEGALIZE ATTACHED PATIO COVER (172 SF). <br />• DEMOLISH EXISTING PERGOLA <br />CONSTRUCTION NOTES <br />1. CONTRACTOR TO PROVIDE EXTERIOR GLAZED OPENINGS FOR <br />NATURAL LIGHT EQUAL TO 1/10TH OF THE FLOOR AREA (10 SQ. FT <br />MIN.) FOR FAMILY ROOM. <br />2. ALL ADDITIONAL ROOMS SHALL HAVE A MIN. OF 7’-6”CEILING <br />HEIGHT (PER 2022 CRC) <br />3. CONTRACTOR TO PROVIDE SMOKE DETECTOR IN EACH SLEEPING <br />ROOM AND AT A POINT CENTRALLY LOCATED IN THE CORRIDOR OF <br />AREA GIVING ACCESS TO EACH SEPARATE SLEEPING AREA AND IN <br />EACH STORY OR BASEMENT AND IF SLEEPING ROOMS ARE AT AN <br />UPPER LEVEL, PROVIDE A DETECTOR AT THE CEILING OF THE <br />UPPER LEVEL IN CLOSE PROXIMITY TO THE STAIRWAY IF <br />APPLICABLE (PER 2022 CRC). <br />4. MASTER BEDROOM SHALL HAVE AT LEAST ONE OPERABLE <br />WINDOW OR DOOR APPROVED FROM EMERGENCY ESCAPE OR <br />RESCUE WHICH SHALL OPEN DIRECTLY ONTO A PUBLIC STREET, <br />PUBLIC ALLEY, YARD OR EXIT COURT. THE OPENING SHALL <br />CONFORM TO THE FOLLOWING: <br />a. MIN AREA = 5.7 SQ FT. <br />b. 20”MIN WIDTH <br />c. 24”MIN HEIGHT <br />d. FINISH SILL AT 44”MAX ABOVE THE FLOOR <br />e. SECURITY BARS/GRILLES MAY BE INSTALLED IF EQUIPPED WITH <br />APPROVED RELEASED DEVICES OPERABLE WITHOUT THE USE OF A <br />KEY OF SPECIAL KNOWLEDGE AND PROVIDED THE BUILDING <br />EQUIPPED WITH SMOKE DETECTOR (PER 2022 CRC). <br />5. PER 2022 CRC: <br />a. NOTCHING OF STUDS IN BEARING PARTITIONS SHALL NOT <br />EXCEED 25% OF THE WIDTH. <br />b. NOTCHING OF STUDS IN NONBEARING PARTITIONS SHALL NOT <br />EXCEED 40% OF THE WIDTH. <br />c. BORED HOLES IN STUD IN BEARING PARTITIONS SHALL NOT <br />EXCEED 40% OF THE WIDTH. <br />d. BORED HOLES IN THE STUDS IN NONBEARING PARTITIONS SHALL <br />NOT EXCEED 60% OF THE WIDTH (UNLESS THE BORED STUDS ARE <br />DOUBLE AND NO MORE THAN TWO SUCH SUCCESSIVE DOUBLE <br />STUDS ARE SO BORED) <br />e. BORE HOLES MAY NOT BE LOCATED NEARER THAN 5/8”TO THE <br />EDGE OF THE STUD AND MAY NOT BE LOCATED IN THE SAME <br />DIRECTION OF THE STUD AS A CUT OR NOTCH. <br />6. PURLINS SHALL NOT BE SMALLER THAN THE SUPPORTED <br />RAFTERS. MAX SPAN OF 2X4 AND 2X6 PURLINS IS 4’-0”AND 6’-0” <br />RESPECTIVELY. STUDS SHALL BE 2X4 MIN. 8-‘0”LONG MAX AND NOT <br />LESS THAN 45 DEGREES FROM THE HORIZONTAL (PER 2022 CRC). <br />7. FOR ATTICS WITH A VERTICAL CLEAR HEIGHT OF 30”OR MORE, <br />PROVIDE A READILY ACCESSIBLE ATTIC ACCESS OPENING IN THE <br />CEILING. OPENING SHALL BE 22X30 MIN. AND HAVE 30”MIN HEAD <br />ROOM (PER 2022 CRC). <br />8. CONTRACTOR TO PROVIDE VENTILATION FOR ATTIC SPACES AND <br />ENCLOSE RAFTER SPACES. VENTILATION OPENINGS SHALL BE NOT <br />LESS THAN 1/150 OF THE AREA VENTILATED. OPENINGS MAY BE <br />REDUCED TO 1/300 IF 50% OF THE OPENING ARE IN THE UPPER <br />PORTION OF THE SPACE AND AT LEAST 3’-0”ABOVE THE EAVES. <br />CORROSION RESISTANT MESH WITH ¼”MAX OPENING IS REQUIRED <br />(PER 2022 CRC). <br />9. IN ACCORDANCE WITH THE 2022 CALIFORNIA GREEN BUILDING <br />STANDARDS CODE AND CALIFORNIA CIVIL CODE SECTION 1101.1; <br />ALL EXISTING RESIDENTIAL BUILDINGS UNDERGOING PERMITTED <br />ALTERATION, ADDITIONS, OR IMPROVEMENTS SHALL REPLACE ALL <br />NON-COMPLIANT PLUMBING FIXTURES WITH WATER CONSERVING <br />PLUMBING FIXTURES PRIOR TO ANY PERMIT FINAL APPROVALS OR <br />THE ISSUANCE OF CERTIFICATE OF OCCUPANCY UNLESS NOTED <br />OTHERWISE. <br />10. WHERE THE PERMIT IS REQUIRED FOR ALTERATION, REPAIRS <br />OR ADDITIONS EXCEEDING $1,000 EXISTING DWELLING THAT HAVE <br />ATTACHED GARAGES OF FUEL-BURNING APPLIANCES SHALL BE <br />PROVIDE WITH CARBON MONOXIDE ALARM(S) IN ACCORDANCE <br />WITH CRC 315.1 EXCEPTIONS: HARD WIRING WITH BATTERY BACKUP <br />INTERCONNECTION IS NOT REQUIRED WITHIN EXISTING DWELLING <br />UNITS WHERE THERE IS NO COMMERCIAL POWER SUPPLY OR ANY <br />ALTERATION OR REPAIRS DOES NOT RESULT IN THE REMOVAL OF <br />WALL AND CEILING FINISHES OR THERE IS NO ACCESS BY MEANS OF <br />ATTIC; BASEMENT OR CRAWL SPACE. <br />11. WHERE ALTERATIONS, REPAIR OR ADDITIONS REQUIRING A <br />PERMIT OCCUR, OR WHEN ONE OR MORE SLEEPING ROOMS ARE <br />ADDED OR CREATED IN EXISTING DWELLING, SMOKE ALARMS <br />LISTED IN ACCORDANCE WITH UL 217 SHALL BE INSTALLED A <br />REQUIRED FOR NEW CONSTRUCTION. R314.3.1 EXCEPTION: HARD <br />WIRING WITH BATTERY BACKUP AND INTERCONNECTIONS IS NOT <br />REQUIRED WITHIN EXISTING DWELLING UNITS WHERE THERE IS NO <br />COMMERCIAL POWER SUPPLY OR ANY ALTERATION OR REPAIR <br />DOES NOT RESULT IN THE REMOVAL OF WALL AND CEILING <br />FINISHES OR THERE IS NO ACCESS BY MEAN OF ATTIC; BASEMENT <br />OR CRAWL SPACE. <br />12. ALL OUTLETS INSTALLED IN DWELLING UNIT BEDROOMS, FAMILY <br />ROOMS, DINING ROMS, LIVING ROOMS, PARLORS, DENS, LIBRARIES, <br />SUN ROOMS, RECREATIONS ROOMS, CLOSETS, HALLWAYS, OR <br />SIMILAR ROOMS OR AREAS SHALL BE PROTECTED BY A LISTED <br />“COMBINES TYPE”ARC-FAULT CIRCUIT INTERRUPTED, INSTALLED TO <br />PROVIDE PROTECTION OF BRANCH CIRCUIT. 2022 CEC, 210.12(B). <br />13. IN ALL AREAS SPECIFIED IN CEC 210.52, ALL NEW 15 AND 20 <br />AMPERE DWELLING UNIT RECEPTACLES SHALL BE LISTED TAMPER <br />RESISTANT RECEPTACLES. 2022 CEC 406.12 <br />14. SEC 903.2.1 CRC ROOF FLASHING SHALL BE INSTALLED IN <br />ACCORDANCE WITH THIS CODE AT ALL WALL AND ROOF <br />INTERSECTIONS, WHEREVER THERE IS A CHANGE IN ROOF SLOPE <br />OR DIRECTION AND AROUND ALL ROOF OPENINGS AND <br />PENETRATIONS, ALL METAL FLASHING SHALL BE CORROSION <br />RESISTANT WITH THICKNESS OF NOT LESS THAN (0.019) INCHES (NO. <br />26 GAGE GALVANIZED SHEET METAL. <br />15. A RADIANT BARRIER IS REQUIRED (FOR CLIMATE ZONES 2-15). <br />RADIANT BARRIERS SHALL MEET SPECIFIC ELIGIBILITY AND <br />INSTALLATION CRITERIA TO RECEIVE ENERGY CREDIT FOR <br />COMPLIANCE WITH THE BUILDING ENERGY EFFICIENCY STANDARDS <br />FOR LOW-RISE RESIDENTIAL BUILDING. REFER TO RA4.2.1 THE <br />EMITTANCE OF THE RADIANT BARRIER SHALL BE LESS THAN OR <br />EQUAL TO 0.05 AS TESTED IN ACCORDANCE WITH ASTM C1371 OR <br />ASTM E408. FOR PRESCRIPTIVE COMPLIANCE, THE ATTIC SHALL BE <br />VENTILATED TO PROVIDE A MINIMUM FREE VENTILATION AREA OF <br />NOT LESS THAN ONE SQ. FT. OF VENT AREA FOR EACH 300 SQ. FT. <br />OF ATTIC FLOOR ARE WITH NO LESS THAN 30% UPPER VENT. RIDGE <br />VENTS OR GABLE END VENTS ARE RECOMMENDED TO ACHIEVE THE <br />BEST PERFORMANCE. THE MATERIAL SHOULD BE CUT TO ALLOW <br />FOR FULL AIRFLOW TO THE VENTING. <br />SITE PLAN LEGEND <br />PROPERTY LINE (E) STRUCTURE <br />(E) STRUCTURE TO BE MODIFIEDCMU WALL W/ <br />FENCE ABOVE <br />6'-0" DECORATIVE <br />IRON FENCE <br />CMU BLOCK WALL <br />VINYL FENCE <br />(N) ADDITION <br />SHEET FLOW @ MIN. 2% SLOPE <br />SHEET FLOW NOTE: <br />IMPERVIOUS IMPERVIOUS SURFACE SHALL BE SLOPED AWAY FROM THE BUILDING AT <br />2% MINIMUM SLOPE FOR A MINIMUM DISTANCE OF 10 FEET; LOT SHALL BE GRADED TO <br />DRAIN SURFACE WATER AWAY FROM FOUNDATION WALLS; GRADE SHALL FALL 6” <br />MINIMUM WITHIN THE FIRST 10 FT. –PER SECTION R401.3 <br />CONSULTANTS <br />STRUCTURAL ENGINEERING: <br />FRANCISCO GARCIA, P.E. <br />FJ ENGINEERING+DESIGN <br />600 W. MAIN ST. SUITE 207 <br />ALHAMBRA, CA 91801 <br />(626)548-3874 <br />MECHANICAL ENGINEERING: <br />LAWRENCE GORDON <br />LRG DESIGNS <br />P.O. BOX 47478 <br />LOS ANGELES, CA 90047 <br />(323)955-9827 <br />DEFFERED SUBMITTALS <br />• N/A <br />UNDERGROUND SLEEVING <br />FOR GAS LINE <br />1. CONDUIT SHALL BE SOLID AND NON-METALIC FOR 1-INCH THROUGH <br />4-INCH SIZE. <br />2. CONDUIT MUST BE A CONTINUOUS LENGTH, AND BENDS MUST BE <br />GRADUAL. <br />3. IF INSTALLED IN SAME TRENCH AS ELECTRICAL LINES, CONDUITS <br />MUST HAVE A MINIMUM SEPARATION EITHER VERTICALLY OR <br />HORIZONTALLY OF 12 INCHES. <br />4. MINIMUM DEPTH SHALL BE 24 INCHES FROM FINAL GRADE. <br />5. CONDUIT SIZE SHALL BE AS FOLLOWS: <br />6. THE ENDS OF THE CONDUIT SHALL BE SEALED TO PREVENT ENTRY <br />OF SOIL OR WATER. <br />7. CONDUIT SHALL BE TAG "GAS" UNDERGROUND. <br />GAS SERVICE SIZE (INCHES) <br />5/8" <br />1-1/8" <br />1-1/4" <br />2" <br />CONDUIT SIZE (INCHES) <br />1" SOLID / NON-METALLIC <br />2" SOLID / NON-METALLIC <br />3" SOLID / NON-METALLIC <br />4" SOLID / NON-METALLIC <br />UNDERGROUND GAS-LINE LEGEND <br />(E) CONC. DRIVEWAY <br />(E) SINGLE- <br />FAMILY <br />RESIDENCE <br />(1121 SF) <br />(E) FRONT <br />PORCH <br />(E) CANOPY TO <br />BE REMOVED <br />AND REBUILT. <br />(E) LANDSCAPE <br />(E) POOL <br />NOT A PART <br />G <br />(E) GAS <br />METER <br />(E) MAIN <br />ELEC. <br />PANEL <br />BIRCH ST. <br />(E) 3/4" WATER <br />METER (V.I.F.) <br />w (E) PARKWAY <br />(E) SIDEWALK <br />50'-0" <br />12 <br />0 <br />' <br />- <br />0 <br />" <br />6' <br />- <br />0 <br />" <br />4' <br />- <br />0 <br />" <br />20'-0" <br />(E) REAR <br />PATIO COVER <br />(N) ADDITION <br />(TO BE LEGALIZED) <br />(249 SF) <br />(E) PERGOLA <br />TO BE REMOVED <br />(E) CONC. <br />PAVING <br />(E) ELECT. <br />SUBPANEL <br />3'-2" <br />TO BE <br />PARTIALLY <br />DEMO. <br />5' <br />- <br />0 <br />" <br />18 <br />' <br />- <br />8 <br />" <br />4'-0" <br />ADDRESS: 1511 <br />(E) GARAGE <br />TO BE CONVERTED <br />TO AN ADU <br />(373 SF) <br />TOTAL ADU SIZE <br />622 SF <br />(E) FENCE <br />(E) GATE W/ ALARM <br />DROWNING <br />PREVENTION ITEMS: <br />(E) FENCE & ALARM <br />1'-0" <br />(E) CONC. DRIVEWAY <br />(E) POOL <br />G <br />BIRCH ST. <br />(E) 3/4" WATER <br />METER (V.I.F.) <br />w (E) PARKWAY <br />(E) SIDEWALK <br />50'-0" <br />12 <br />0 <br />' <br />- <br />0 <br />" <br />(E) CONC. <br />PAVING <br />6' <br />- <br />0 <br />" <br />4' <br />- <br />0 <br />" <br />20'-0" <br />6' <br />- <br />0 <br />" <br />(E) SINGLE-FAMILY <br />RESIDENCE <br />(1121 SF) <br />(E) FRONT <br />PORCH <br />NOT A PART <br />(E) MAIN <br />ELEC. <br />PANEL <br />(E) REAR PATIO COVER <br />(N) PATIO COVER <br />(N) ADDITION <br />(TO BE LEGALIZED) <br />(249 SF) <br />(E) GARAGE <br />TO BE CONVERTED <br />TO AN ADU <br />(373 SF) <br />(E) ELECT. <br />SUBPANEL <br />(E) LANDSCAPE <br />(E) GAS <br />METER <br />(E) FENCECLR. <br />5'-0" <br />13'-9" <br />11 <br />' <br />- <br />8 <br />" <br />@ <br />W <br />A <br />L <br />L <br />(E <br />) <br /> <br />5 <br />' <br />- <br />0 <br />" <br />@ <br />R <br />O <br />O <br />F <br />(E <br />) <br /> <br />3 <br />' <br />- <br />9 <br />" <br />@ ROOF/WALL <br />4'-0" <br />18 <br />' <br />- <br />7 <br />" <br />13'-4 1/2" <br />SL <br />O <br />P <br />E <br />1511 S. BIRCH STREET <br />SANTA ANA, CA 90727 <br />1513 S. BIRCH STREET <br />SANTA ANA, CA 90727 <br />(E) GATE W/ ALARM <br />DROWNING <br />PREVENTION ITEMS: <br />(E) FENCE & ALARM <br />TOTAL ADU SIZE <br />622 SF <br />1'-0" <br />ISSUED <br />DATE: <br />REVISIONS <br />DRAWINGS, SPECIFICATIONS AND OTHER VISUAL AIDS, AS <br />INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE <br />DRAFTER/DESIGNER WHETHER THE PROJECT FOR <br />WHICH THEY ARE MADE BE EXECUTED OR NOT, AND <br />THEY ARE NOT TO BE USED FOR ANY OTHER SITE THAN <br />THE ONE FOR WHICH THEY ARE PREPARED, EXCEPT BY <br />AGREEMENT IN WRITING. <br />NO <br />. <br /> <br />D <br />E <br />S <br />C <br />R <br />I <br />P <br />T <br />I <br />O <br />N <br /> <br />D <br />A <br />T <br />E <br />DRAFTER/DESIGNER: <br />LUIS N OROZCO <br />562.661.9281 <br />LUIS.OROZCO.A@LIVE.COM <br />DATE: <br />11/19/2024 <br />G101 <br />COVER SHEET <br />PR <br />O <br />P <br />E <br />R <br />T <br />Y <br /> <br />O <br />W <br />N <br />E <br />R <br />: <br /> <br />S <br />I <br />L <br />V <br />I <br />A <br /> <br />T <br />O <br />R <br />R <br />E <br />S <br />15 <br />1 <br />1 <br /> <br />S <br />. <br /> <br />B <br />I <br />R <br />C <br />H <br /> <br />S <br />T <br />. <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br /> <br />9 <br />0 <br />7 <br />2 <br />7 <br />GA <br />R <br />A <br />G <br />E <br /> <br />C <br />O <br />N <br />V <br />E <br />R <br />S <br />I <br />O <br />N <br /> <br />T <br />O <br /> <br />A <br />N <br />AC <br />C <br />E <br />S <br />S <br />O <br />R <br />Y <br /> <br />D <br />W <br />E <br />L <br />L <br />I <br />N <br />G <br /> <br />U <br />N <br />I <br />T <br />09/10/2024 <br />SHEET INDEXADU -GARAGE CONVERSION <br />1511 S. BIRCH ST., SANTA ANA, CA 90727 -SFR <br />APPLICABLE CODES <br />THIS PROJECT SHALL COMPLY WITH THE FOLLOWING: <br />2022 CALIFORNIA BUILDING CODE -TITLE 24, PART 2 <br />2022 CALIFORNIA RESIDENTIAL CODE -TITLE 24, PART 2.5 <br />2022 CALIFORNIA MECHANICAL CODE -TITLE 24, PART 4 <br />2022 CALIFORNIA PLUMBING CODE -TITLE 24, PART 5 <br />2022 CALIFORNIA ELECTRICAL CODE -TITLE 24, PART 3 <br />2022 CALIFORNIA ENERGY CODE -TITLE 24, PART 6 <br />2022 CALIFORNIA GREEN BUILDING STANDARDS CODE - <br />TITLE 24, PART 11 <br />2022 ORANGE COUNTY FIRE CODE <br />CITY OF SANTA ANA REGULATIONS AND ORDINANCES <br />BUILDING DATA <br />CONSTRUCTION TYPE: V-B -RESIDENTIAL PRESCRIPTIVE WOOD <br />NUMBER OF STORIES/ HEIGHT: ONE STORY <br />FIRE SPRINKLER SYSTEM: NONE EXISTING/ NONE REQUIRED <br />BASEMENT: NO <br />TYPE OF ROOF: ASPHALT COMPOSITION SHINGLES <br />OCCUPANCY LOADS: <br />ADU: R-3 OCCUPANCY (200 OCCUPANT LOAD) = 373/200= 2 OCCUPANTS <br />CAL. GREEN BLDG. <br />STANDARDS <br />1. ALL FINISH MATERIALS, SUCH AS ADHESIVES, SEALANTS, <br />CAULKS, PAINTS, AEROSOLS PAINTS, COATING, CARPET <br />SYSTEMS, RESILIENT FLOORING SYSTEMS AND COMPOSITE <br />WOOD PRODUCTS SHALL CONFORM TO THE VOC. AND <br />FORMALDEHYDE LIMITS SET FORTH IN SECTION 4.504.2. 4.504.3, <br />4.504.4, 4.504.5 AND TABLE 4.504.1, 4.504.2, 4.504.3 AND 4.504.5 <br />(4.405.2 CGBSC) <br />2. BATHROOM EXHAUST FANS, A ROOM WHICH CONTAINS A <br />BATHTUB, SHOWER OR TUB/SHOWER COMBINATION, SHALL <br />COMPLY WITH THE FOLLOWING. PROVIDE NOTES ON THE PLANS. <br />(4.506.1 CGBSC) <br />A) FANS SHALL BE ENERGY STAR COMPLIANT AND BE <br />DUCTED TO TERMINATE OUTSIDE THE BUILDING. <br />B) UNLESS FUNCTIONING AS A COMPONENT OF A WHOLE <br />HOUSE VENTILATION SYSTEM, THE FAN MUST BE <br />CONTROLLED BY A HUMIDISTAT WHICH SHALL BE <br />READILY ACCESSIBLE. HUMIDISTAT CONTROLS SHALL BE <br />CAPABLE OF ADJUSTMENT BETWEEN A RELATIVE <br />HUMIDITY RANGE OF 50 TO 80%. A HUMIDITY CONTROL <br />MAY BE A SEPARATE COMPONENT TO AN EXHAUST FAN <br />AND IS NOT REQUIRED TO BE INTEGRAL (I.E. BUILT-IN). <br />ASSESSOR'S MAP VICINITY MAP <br />NORTH <br />01 - GENERAL <br />G101 COVER SHEET <br />G102 GENERAL NOTES <br />G103 GENERAL NOTES <br />G104 CALGREEN RESIDENTIAL MANDATORY MEASURES <br />G105 CALGREEN RESIDENTIAL MANDATORY MEASURES <br />02 - ARCHITECTURAL <br />A101 FLOOR PLANS <br />A102 REFLECTED CEILING PLAN & ROOF PLAN <br />A201 EXTERIOR ELEVATIONS <br />A301 ENLARGED FLOOR PLANS & INTERIOR ELEVATIONS <br />A401 WALL SECTIONS <br />A501 DETAILS - CONSTRUCTION <br />A502 DETAILS - CONSTRUCTION <br />A503 DETAILS - TYP. CONSTRUCTION <br />A601 SCHEDULES <br />STRUCTURAL <br />S-0 STRUCTURAL NOTES & SCHEDULES <br />S-1 FOUNDATION PLA <br />S-2 CEILING AND ROOF FRAMING PLANS <br />SD-1 STRUCTURAL DETAILS <br />T24 / CALGREEN <br />T24 1 CERTIFICATE OF COMPLIANCE FORMS <br />T24 2 CERTIFICATE OF COMPLIANCE FORMS <br />T24 3 RESIDENTIAL MEASURES SUMMARY <br />GRAND TOTAL: 21 1 <br />P <br />L <br />A <br />N <br />N <br />I <br />N <br />G <br /> <br />1 <br />S <br />T <br /> <br />P <br />C <br /> <br />R <br />E <br />S <br />U <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br /> <br />1 <br />0 <br />/ <br />2 <br />3 <br />/ <br />2 <br />0 <br />2 <br />4 <br />2 <br />B <br />U <br />I <br />L <br />D <br />I <br />N <br />G <br /> <br />S <br />U <br />B <br />M <br />I <br />T <br />T <br />A <br />L <br /> <br />1 <br />1 <br />/ <br />1 <br />9 <br />/ <br />2 <br />0 <br />2 <br />4 <br />Scale:3/32" = 1'-0"1 SP - EXISTING <br />Scale:3/32" = 1'-0"2 SP - PROPOSED <br />NORTH NOTES: <br />-ALL UTILITY CABLES OR WIRES <br />BETWEEN THE PRIMARY RESIDENCE <br />AND THE DETACHED ADU SHALL BE <br />PLACED UNDERGROUND PER <br />SECTION 41-626 OF THE SAMC <br />-NO EASEMENTS LOCATED ON <br />PROPERTY <br />1513 S. BIRCH ST., SANTA ANA, CA 90727 -ADU <br />ADU / SFD = 622 SF/ 1121 SF = .55% <br />THE ADU/SFD RATIO IS FOR PARK & REC FEE PURPOSE <br />ONLY. THE APPLICANT IS RESPONSIBLE FOR THE GIVEN <br />SFR PERCENTAGE OF THE EXISTING PRIMARY <br />RESIDENCE; BUILDING SAFETY STAFF ARE NOT <br />RESPONSIBLE FOR THE ACCURACY OF THE GIVEN SFR <br />SF. <br />MECHANICAL, ELECTRICAL AND PLUMBING ARE NOT <br />PART OF THIS PLAN REVIEW AND APPROVAL. THE <br />BUILDING AND SAFETY DIVISION PLAN REVIEW DOES NOT <br />INCLUDE POTENTIAL ELECTRICAL, WATER, OR GAS <br />REVISIONS REQUIRED BY ANY NON-CITY UTILITY <br />COMPANY. IT IS SOLELY ON THE CONTRACTOR TO <br />ENSURE PROPOSED ADDITION OR ALTERATION CAN AND <br />WILL MEET UTILITY COMPANY REQUIREMENTS. MEP ARE <br />SUBJECT TO BUILDING FIELD INSPECTION. <br />Bldg #102122347 <br />APPROVALS: <br />PLNG - C. Santana <br />BLDG - J, Lo <br />POLICE - B. Martin <br />PUBLIC WORKS - Y. Soto