2130 E 17th St - Plan
PBA
>
Building
>
ProjectDox
>
S
>
Seventeenth St
>
2130 E Seventeenth St Unit# A
>
2130 E 17th St - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/30/2025 1:40:33 PM
Creation date
5/30/2025 8:00:52 AM
Metadata
Fields
Template:
Plan
Permit Number
101112794
Full Address
2130 E Seventeenth St Unit# A
Document Relationships
101112794 - Permit
(Permit - Plan)
Path:
\Building\Permits\S\Seventeenth St\2130 E Seventeenth St Unit# A
Text box
ID:
1
Creator:
Import Agent
Created:
5/30/2025 10:00 AM
Modified:
5/30/2025 8:28 AM
Text:
http://www.icc-es.org/
ID:
2
Creator:
Import Agent
Created:
5/30/2025 10:00 AM
Modified:
5/30/2025 8:28 AM
Text:
http://www.icc-es.org
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
123
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed <br />as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as <br />to any finding or other matter in this report, or as to any product covered by the report. <br />Copyright © 2022 ICC Evaluation Service, LLC. All rights reserved. Page 20 of 21 <br />ICC-ES Evaluation Report ESR-1308 CBC Supplement <br />Reissued December 2022 <br />This report is subject to renewal December 2023. <br />www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council ® <br />DIVISION: 09 00 00—FINISHES <br />Section: 09 22 26—Suspension Systems <br />Section: 09 53 00—Acoustical Ceiling Suspension Assemblies <br />REPORT HOLDER: <br />WORTHINGTON ARMSTRONG VENTURE (WAVE) <br />EVALUATION SUBJECT: <br />FIRE- AND NONFIRE-RESISTANCE-RATED SUSPENDED CEILING FRAMING SYSTEMS <br />1.0 REPORT PURPOSE AND SCOPE <br />Purpose: <br />The purpose of this evaluation report supplement is to indicate that the Fire- and Nonfire-Resistance-Rated Suspended Ceiling <br />Systems, described in ICC-ES evaluation report ESR-1308, have also been evaluated for compliance with the code noted <br />below. <br />Applicable code edition: <br /> 2019 California Building Code (CBC) <br />For evaluation of applicable chapters adopted by the California Office of Statewide Health Planning and Development <br />(OSHPD) AKA: California Department of Health Care Access and Information (HCAI) and the Division of State Architect (DSA), <br />see Sections 2.1.1 and 2.1.2 below. <br />2.0 CONCLUSIONS <br />The Fire- and Nonfire-Resistance-Rated Suspended Ceiling Systems, described in Sections 2.0 through 7.0 of the evaluation <br />report ESR-1308, comply with CBC Chapters 8, 16, 17 and 25, provided the design and installation are in accordance with the <br />2018 International Building Code (IBC) provisions, as applicable, noted in the evaluation report, and the additional <br />requirements of CBC Chapters 8, 16, 17 and 25, as applicable. <br />2.1. OSHPD: <br />The Fire- and Nonfire-Resistance-Rated Suspended Ceiling Systems, described in Section 2.0 through 7.0 of the evaluation <br />report ESR-1308, comply with CBC Chapters 8, 16, 17 and 25, with applicable amendments, and Chapters 16A and 17A, <br />provided the design and installation are in accordance with the 2018 International Building Code (IBC) provisions noted in <br />the evaluation report, and the additional requirements in Sections 2.1.1 through 2.1.2 of this supplement: <br />2.1.1. Conditions of Use: <br />1. All loads applied shall be determined by a registered structural engineer and shall comply with applicable loads from <br />CBC Chapter 16 and its amendments, and Chapter 16A. <br />2. Section 13.5.6.2 of ASCE 7 shall be revised in accordance with CBC Section 1617A.1.21 [OSHPD 1 & 4]. <br />3. Design and installation shall comply with the requirements of OSHPD Preapproved Details (OPD) OPD-0002-13 and <br />OPD-0003-13, as applicable. <br />2.1.2. Special Inspection Requirements: <br />1. Periodic special inspection is required, in accordance with Section 1705A.12.5 of the CBC [OSHPD 1 & 4]. <br />2. Where gypsum wallboard is used in suspended ceiling installations, additional inspection shall be in accordance with <br />CBC Section 2503.2 [OSHPD 1, 1R, 2, 4 & 5]. <br />2.2. DSA: <br />The Fire- and Nonfire-Resistance-Rated Suspended Ceiling Systems, described in Section 2.0 through 7.0 of the evaluation <br />report ESR-1308, comply with CBC Chapters 8, 16, 17 and 25, with applicable amendments, and Chapters 16A and 17A, <br />2130 E 17th St - <br />10111279406/07/23
The URL can be used to link to this page
Your browser does not support the video tag.