My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1202 W Edinger Ave - Plan
PBA
>
Building
>
ProjectDox
>
E
>
Edinger Ave
>
1202 W Edinger Ave
>
1202 W Edinger Ave - Plan
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/1/2025 11:56:49 AM
Creation date
6/1/2025 11:56:24 AM
Metadata
Fields
Template:
Plan
Permit Number
20180981
40138401
101116627
Full Address
1202 W Edinger Ave
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
307
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
1 (TYPICAL) <br />X (TYPICAL) <br />2 (TYPICAL) <br />L <br />L <br />ab <br />ab <br />ab <br />ab <br />DP1-25,27 <br />25a/25EB25a25a/25EB <br />25a 25a25a <br />27b 27b27b <br />27b 27b/27EB27b/27EB <br />27EB <br />27EB <br />25EB <br />25EB <br />DP1-29 <br />DP1-29 <br />/29EB <br />DP1-29 <br />/29EB <br />DP1-29 <br />/29EB <br />DP1-29 <br />/29EB <br />8. <br />7. <br />REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXIT SIGN <br />CHEVRONS AND NUMBER OF FACES PER EXIT SIGN. ANY DISCREPANCIES <br />BETWEEN EXIT SIGNS SHOWN ON THE ELECTRICAL AND ARCHITECTURAL <br />PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO <br />ORDERING EXIT SIGNS. <br />LIGHTING PLAN GENERAL NOTES: <br />PROVIDE ADDITIONAL J-BOX NEAR PANEL FOR MULTIPLE HOMERUN CIRCUITRY. <br />10. <br />UNLESS SPECIFICALLY SHOWN AS (E), (R), (ER), (D), EXISTING OR NON-BOLD, <br />ALL ELECTRICAL DEVICES SHOWN ARE NEW. <br />REFER TO GENERAL POWER PLAN NOTES AND COMMUNICATIONS PATHWAYS <br />GENERAL NOTE FOR ADDITIONAL REQUIREMENTS WHEN POWER AND/OR DATA <br />DEVICES ARE SHOWN ON THIS PLAN. <br />6. <br />5. <br />ALL LINE VOLTAGE DIMMING BRANCH CIRCUITS SHALL BE PROVIDED WITH A <br />DEDICATED NEUTRAL CONDUCTOR FOR EACH ZONE/CHANNEL. <br />4. <br />3. <br />2. <br />1.REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION AND ELEVATION OF <br />ALL LIGHTING FIXTURES AND ALL DEVICES. ALL WALL-MOUNTED DEVICE <br />HEIGHTS SHALL BE VERIFIED WITH THE ARCHITECT PRIOR TO ROUGH-IN. <br />VERIFY EXACT CEILING CONSTRUCTION WITH ARCHITECTURAL REFLECTED <br />CEILING PLAN AND SPECS. PROVIDE LIGHTING FIXTURES WITH ALL NECESSARY <br />MOUNTING HARDWARE. <br />ALL RECESSED FIXTURES SHALL BE PROVIDED WITH ALL STRUCTURAL <br />SUPPORTS AS REQUIRED BY THE IBC, OR CBC WHERE ADOPTED, IN ADDITION TO <br />ANY LOCAL CODES. <br />9. <br />a. <br />b. <br />c. <br />WHEN EXPOSED CEILINGS OR OPEN GRID CONDITIONS OCCUR, THE <br />CONTRACTOR WILL NEED TO PROVIDE THE FOLLOWING ITEMS: <br />ALL BRANCH CIRCUITS SHALL BE EMT. <br />ALL BRANCH CIRCUITS SHALL BE ROUTED ORTHOGONALLY, NEATLY <br />TRAINED, IN PARALLEL TO STRUCTURES OR DUCTWORK. THE TERM <br />"TRAINED" MEANS ALL PARALLEL CONDUITS SHALL MAINTAIN THE SAME <br />SPATIAL RELATIONSHIP WITH EACH OTHER FOR ENTIRE RUN TO INCLUDE <br />RADIUS BENDS AND SWEEPS. <br />VISUALLY OBJECTIONABLE BRANCH CIRCUITS WILL BE REROUTED AT THE <br />REQUEST OF THE ARCHITECT AT NO ADDITIONAL COST. <br />ALL BRANCH CIRCUITS, FIRE ALARM CIRCUITS, LIGHTING CONTROL <br />CONDUCTORS, AND CONDUITS/SLEEVES FOR AV/TEL/DATA/SECURITY AND <br />OTHER TECHNOLOGY SYSTEMS INFRASTRUCTURE SHALL BE ROUTED IN EMT <br />WITHIN SUCH AREA. OPEN CONDUCTORS AND MC CABLES SHALL NOT BE <br />UTILIZED IN THESE AREAS. <br />ALL CONDUITS/SLEEVES IN THESE SPACES SHALL BE EXTENDED INTO/ABOVE <br />CONCEALED ACCESSIBLE CEILING SPACES - TERMINATING A MINIMUM OF 5FT <br />HORIZONTALLY FROM THE OPEN OR EXPOSED CEILING CONDITION. <br />REVIEW PROPOSED ROUTING OF CONDUIT WITH ARCHITECT PRIOR TO <br />INSTALLATION. VISUALLY OBJECTIONABLE BRANCH CIRCUITS/CONDUIT SHALL BE <br />REROUTED AT THE REQUEST OF THE ARCHITECT AT NO ADDITIONAL COST. <br />IN AREAS WITH "OPEN" CEILINGS, "EXPOSED" CEILINGS, OR OPEN GRID (NO TILES <br />INSERTED) OR GRID CEILINGS WITH MORE THAN 25% OPEN OR TRANSPARENT <br />AREA ALLOWING BEAMS AND OTHER STRUCTURAL ELEMENTS, HVAC DUCT WORK, <br />ETC., TO BE VIEWABLE BY THE OCCUPANTS. THE ELECTRICAL CONTRACTOR SHALL <br />TAKE EXTRA CARE WITH INSTALLATION OF CONDUIT TO INCLUDE MEETING THE <br />FOLLOWING ADDITIONAL INSTALLATION CRITERIA: <br />- <br />CONDUIT FOR ALL BRANCH CIRCUITS, FIRE ALARM CIRCUITS, LIGHTING <br />CONTROL CONDUCTORS AV/TEL/DATA INFRASTRUCTURE SHALL BE ROUTED <br />NEATLY, TIGHT TO THE DECK ABOVE AND PARALLEL TO STRUCTURAL <br />BEAMS/FRAMING, DUCT WORK AND PLUMBING RELATED PIPING. <br />- <br />- <br />OPEN CEILING COORDINATION NOTES: <br />tk1sc project number: B2305501.000 <br />drawn by:checked by: <br />drawing no.: <br />ar <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />u <br />r <br />e <br />pl <br />a <br />n <br />n <br />i <br />n <br />g <br />in <br />t <br />e <br />r <br />i <br />o <br />r <br />s <br />tB <br />P <br />/ <br />A <br />r <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />u <br />r <br />e <br />46 <br />1 <br />1 <br /> <br />T <br />e <br />l <br />l <br />e <br />r <br /> <br />A <br />v <br />e <br />n <br />u <br />e <br />Ne <br />w <br />p <br />o <br />r <br />t <br /> <br />B <br />e <br />a <br />c <br />h <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />6 <br />6 <br />0 <br />ph <br />: <br /> <br />9 <br />4 <br />9 <br />. <br />6 <br />7 <br />3 <br />. <br />0 <br />3 <br />0 <br />0 <br />consultant <br />agency <br />owner <br />date: <br />drawing title: <br />description:date:Rev: <br />tBP project number : <br />architect <br />THIS DRAWING AND THE DESIGNS, DEPICTIONS, IDEAS AND OTHER INFORMATION <br />CONTAINED HEREIN CONSTITUTE UNPUBLISHED WORK OF tBP/ARCHITECTURE AND <br />SHALL REMAIN THE PROPERTY OF tBP/ARCHITECTURE IN PERPETUITY. NO PART <br />THEREOF SHALL BE REPRODUCED, DISCLOSED, DISTRIBUTED, SOLD, PUBLISHED OR <br />OTHERWISE USED IN ANY WAY WITHOUT THE ADVANCED EXPRESS WRITTEN CONSENT <br />OF tBP/ARCHITECTURE. <br />ph: 714.667.2700 <br />SANTA ANA, CA 92701 <br />20 CIVIC CENTER PLAZA <br />SANTA ANA PLANNING AND BUILDING AGENCY <br /># <br />DA <br />N <br />C <br />E <br /> <br />S <br />T <br />U <br />D <br />I <br />O <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />12 <br />0 <br />2 <br /> <br />W <br /> <br />E <br />D <br />I <br />N <br />G <br />E <br />R <br /> <br />A <br />V <br />E <br />MA <br />T <br />E <br />R <br /> <br />D <br />E <br />I <br /> <br />H <br />I <br />G <br />H <br /> <br />S <br />C <br />H <br />O <br />O <br />L <br />21125.00 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />12 <br />0 <br />2 <br /> <br />W <br /> <br />E <br />D <br />I <br />N <br />G <br />E <br />R <br /> <br />A <br />V <br />E <br />MA <br />T <br />E <br />R <br /> <br />D <br />E <br />I <br /> <br />H <br />I <br />G <br />H <br /> <br />S <br />C <br />H <br />O <br />O <br />L <br />21125.00 <br />09/06/2023 <br />11870 Pierce Street, Suite 160 <br />Riverside, California 92505 <br />951.299.4160 www.tk1sc.com <br />Project Leader - Bill Voller <br />tk1sc Job #: B2305501.000 <br />Electrical Lead - Marie Rothenberger <br />City Submittal 09/06/23- <br /> 1/8" = 1'-0" <br />LIGHTING PLAN 1 <br />LIGHTING PLAN <br />E1-1 <br />21159.00 <br />1202 W Edinger <br />Ave10/3/2024
The URL can be used to link to this page
Your browser does not support the video tag.