HVLS <br />1 <br />2 <br />J <br />3 <br />F <br />ERC <br />2 <br />J <br />2 <br />3 <br />F <br />ERC <br />3 <br />J <br />2 <br />3 <br />F <br />ERC <br />1 <br />J <br />2 <br />3 <br />F <br />ERC <br />4 <br />J2 <br />3 <br />F <br />DP1-49,51 <br />DP1-49 <br />DP1-51DP1-49 <br />DP1-49 <br />DP1-51 <br />DP1-51 <br />DP1-53,55 <br />DP1-53 <br />DP1-55 <br />DP1-53 <br />DP1-53 DP1-55 <br />DP1-55 <br />W.P. <br />1 <br />DP1 <br />W.P.TD1 <br />W.P.CBD1 <br />SEE OVERALL <br />ELECTRICAL <br />SITE PLAN <br />CBD1 <br />tk1sc project number: B2305501.000 <br />drawn by:checked by: <br />drawing no.: <br />ar <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />u <br />r <br />e <br />pl <br />a <br />n <br />n <br />i <br />n <br />g <br />in <br />t <br />e <br />r <br />i <br />o <br />r <br />s <br />tB <br />P <br />/ <br />A <br />r <br />c <br />h <br />i <br />t <br />e <br />c <br />t <br />u <br />r <br />e <br />46 <br />1 <br />1 <br /> <br />T <br />e <br />l <br />l <br />e <br />r <br /> <br />A <br />v <br />e <br />n <br />u <br />e <br />Ne <br />w <br />p <br />o <br />r <br />t <br /> <br />B <br />e <br />a <br />c <br />h <br />, <br /> <br />C <br />A <br /> <br />9 <br />2 <br />6 <br />6 <br />0 <br />ph <br />: <br /> <br />9 <br />4 <br />9 <br />. <br />6 <br />7 <br />3 <br />. <br />0 <br />3 <br />0 <br />0 <br />consultant <br />agency <br />owner <br />date: <br />drawing title: <br />description:date:Rev: <br />tBP project number : <br />architect <br />THIS DRAWING AND THE DESIGNS, DEPICTIONS, IDEAS AND OTHER INFORMATION <br />CONTAINED HEREIN CONSTITUTE UNPUBLISHED WORK OF tBP/ARCHITECTURE AND <br />SHALL REMAIN THE PROPERTY OF tBP/ARCHITECTURE IN PERPETUITY. NO PART <br />THEREOF SHALL BE REPRODUCED, DISCLOSED, DISTRIBUTED, SOLD, PUBLISHED OR <br />OTHERWISE USED IN ANY WAY WITHOUT THE ADVANCED EXPRESS WRITTEN CONSENT <br />OF tBP/ARCHITECTURE. <br />ph: 714.667.2700 <br />SANTA ANA, CA 92701 <br />20 CIVIC CENTER PLAZA <br />SANTA ANA PLANNING AND BUILDING AGENCY <br /># <br />DA <br />N <br />C <br />E <br /> <br />S <br />T <br />U <br />D <br />I <br />O <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />12 <br />0 <br />2 <br /> <br />W <br /> <br />E <br />D <br />I <br />N <br />G <br />E <br />R <br /> <br />A <br />V <br />E <br />MA <br />T <br />E <br />R <br /> <br />D <br />E <br />I <br /> <br />H <br />I <br />G <br />H <br /> <br />S <br />C <br />H <br />O <br />O <br />L <br />21125.00 <br />SA <br />N <br />T <br />A <br /> <br />A <br />N <br />A <br />, <br /> <br />C <br />A <br />L <br />I <br />F <br />O <br />R <br />N <br />I <br />A <br /> <br />9 <br />2 <br />7 <br />0 <br />7 <br />12 <br />0 <br />2 <br /> <br />W <br /> <br />E <br />D <br />I <br />N <br />G <br />E <br />R <br /> <br />A <br />V <br />E <br />MA <br />T <br />E <br />R <br /> <br />D <br />E <br />I <br /> <br />H <br />I <br />G <br />H <br /> <br />S <br />C <br />H <br />O <br />O <br />L <br />21125.00 <br />09/06/2023 <br />11870 Pierce Street, Suite 160 <br />Riverside, California 92505 <br />951.299.4160 www.tk1sc.com <br />Project Leader - Bill Voller <br />tk1sc Job #: B2305501.000 <br />Electrical Lead - Marie Rothenberger <br />City Submittal 09/06/23- <br />POWER & COMMUNICATIONS PLAN 1 <br />POWER & <br />COMMUNICATION PLAN <br />E1-2 <br /> 1/8" = 1'-0" <br />8. <br />7. <br />6. <br />5. <br />4. <br />3. <br />2. <br />1. <br />GENERAL NOTES: <br />COMMUNICATIONS PATHWAYS <br />PLAN NOTES: <br />POWER PLAN GENERAL NOTES: <br />3. <br />2. <br />1.ALL RECEPTACLES ON COMMON WALLS SHALL BE SEPARATE BOXES AND <br />OFFSET 24-INCHES MINIMUM. <br />ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROTECTED FROM <br />THE SPREAD OF FIRE WITH AN APPROVED FIRESTOP SYSTEM EQUAL OR <br />GREATER THAN THE FIRE RATING OF THE WALL. <br />ALL WALL-MOUNTED DEVICE HEIGHTS SHALL BE VERIFIED WITH THE ARCHITECT <br />PRIOR TO ROUGH-IN. <br />CONDUITS SHALL (a) CONTAIN NO CONTINUOUS SECTIONS LONGER THAN 30M (98 <br />FT.), AND (b) CONTAIN NO MORE THAN (2) 90° BENDS OR (1) REVERSE BEND <br />WITHOUT INSTALLING A PULL BOX. SPLIT CONDUITS IN PLACE OF PULL BOXES <br />ARE UNACCEPTABLE. <br />CONDUITS SHALL CONTAIN PLASTIC OR NYLON PULL TAPE RATED AT 200 LBS. <br />WITH A MINIMUM OF 5 FEET OF EXTRA PULL TAPE COILED AT EACH END. <br />CONDUIT BEND RADIUS SHALL BE (a) A MINIMUM OF 6 TIMES THE INTERNAL <br />CONDUIT DIAMETER FOR CONDUITS 2-INCHES IN DIAMETER OR LESS, AND (b) 10 <br />TIMES THE INTERNAL CONDUIT DIAMETER FOR CONDUITS MORE THAN 2-INCHES <br />IN DIAMETER. <br />TERMINATE CONDUIT STUBS AND SLEEVES THAT PROTRUDE THROUGH <br />STRUCTURAL FLOORS 2-INCHES TO 3-INCHES ABOVE THE FLOOR SURFACE. <br />INSTALL BUSHINGS OR BELL ENDS AS REQUIRED ON ALL CONDUITS. <br />FLEX CONDUIT IS UNACCEPTABLE FOR USE AS A COMMUNICATIONS CONDUIT <br />EXCEPT AT SEISMIC JOINTS AND/OR IF APPROVED IN WRITING BY THE ENGINEER. <br />ALL UNDER SLAB OR IN-SLAB CONDUITS SHALL BE INSTALLED IN A MANNER THAT <br />PREVENTS WATER INFILTRATION OF THE CONDUIT. IT IS THE CONTRACTOR'S <br />RESPONSIBILITY TO ENSURE GROUND WATER, RAIN WATER OR CONSTRUCTION <br />WATER IS PREVENTED FROM ENTERING AND/OR REMOVED FROM THE CONDUITS <br />PRIOR TO PLACEMENT OF COMMUNICATIONS CABLES. SEE ELECTRICAL <br />SPECIFICATIONS, DETAILS AND PLANS FOR ADDITIONAL CONDUIT SEALING <br />REQUIREMENTS. <br />4.WHEN EXPOSED CEILINGS OR OPEN GRID CONDITIONS OCCUR, THE <br />CONTRACTOR WILL NEED TO PROVIDE THE FOLLOWING ITEMS: <br />EXPOSED CABLE/CONDUCTORS INSTALLED IN A PLENUM SPACE SHALL <br />CONFORM TO NEC, OR CEC WHERE ADOPTED, ARTICLE 300.22(C). <br />5. <br />ALL PULL BOXES SHALL BE SIZED AND INSTALLED PER ANSI-TIA-569-C. PULL <br />BOXES FOR IN/UNDER SLAB CONDUIT RUNS ARE NOT PERMITTED UNLESS <br />OTHERWISE NOTED. PULL BOXES FOR OVERHEAD CONDUIT RUNS SHALL BE <br />LOCATED ABOVE ACCESSIBLE CEILINGS WITHIN THE ACCESSIBLE CEILING SPACE <br />AND SUPPORTED INDEPENDENTLY FROM THE STRUCTURE AND CONDUIT <br />SUPPORTS. PULL BOXES FOR ROOF MOUNTED OR EXTERIOR ABOVE GRADE <br />APPLICATIONS SHALL BE NEMA 3R RATED. PULL BOXES SHALL BE SIZED <br />ACCORDING TO THE FOLLOWING: <br />9. <br />PROVIDE LABELING OF EACH CONDUIT PER GENERAL ELECTRICAL <br />SPECIFICATIONS. <br />10. <br />CONDUIT(S) SHALL EXIT A PULL BOX ON THE WALL OPPOSITE THE WALL <br />ENTERED. <br />PROVIDE INTERNAL/EXTERNAL GAS AND WATER TIGHT MECHANICAL <br />SEALING/PLUGGING OF EACH BUILDING ENTRY CONDUIT AS SPECIFIED <br />ELSEWHERE IN THE DRAWINGS AND SPECIFICATIONS. <br />11. <br />6.PROVIDE G.F.C.I. TYPE RECEPTACLE(S) OR RECEPTACLE(S) PROTECTED BY A <br />GFCI CIRCUIT BREAKER(S) WHEN RECEPTACLES ARE 50A OR LESS, 150V TO <br />GROUND OR LESS AND ARE LOCATED WITHIN 6-FEET OF ANY SINK OR <br />THERAPEUTIC TUB, LAUNDRY AREA, SERVING ANY DRINKING FOUNTAIN OR <br />VENDING MACHINE, WITHIN ANY KITCHEN SPACE, LOCKER ROOM AREA, GARAGE <br />AND BATHROOM SPACE AND/OR LOCATED OUTDOORS. WHERE RECEPTACLES <br />ARE NOT READILY ACCESSIBLE, PROVIDE GFCI CIRCUIT BREAKER(S) TO <br />PROTECT THE RESPECTIVE BRANCH CIRCUIT AND PROVIDE ADDITIONAL <br />NEUTRAL CONDUCTORS IN THE BRANCH CIRCUITING AS REQUIRED TO ENSURE <br />PROPER GFCI FUNCTION. <br />8.UNLESS SPECIFICALLY SHOWN AS (E), (R), (ER), (D), EXISTING OR NON-BOLD, ALL <br />ELECTRICAL DEVICES SHOWN ARE NEW. <br />1 <br />PROVIDE ADDITIONAL J-BOX NEAR PANEL FOR MULTIPLE HOMERUN CIRCUITRY.7. <br />a. <br />b. <br />c. <br />ALL BRANCH CIRCUITS SHALL BE EMT. <br />ALL BRANCH CIRCUITS SHALL BE ROUTED ORTHOGONALLY, NEATLY <br />TRAINED, IN PARALLEL TO STRUCTURES OR DUCTWORK. THE TERM <br />"TRAINED" MEANS ALL PARALLEL CONDUITS SHALL MAINTAIN THE SAME <br />SPATIAL RELATIONSHIP WITH EACH OTHER FOR ENTIRE RUN TO INCLUDE <br />RADIUS BENDS AND SWEEPS. <br />VISUALLY OBJECTIONABLE BRANCH CIRCUITS WILL BE REROUTED AT THE <br />REQUEST OF THE ARCHITECT AT NO ADDITIONAL COST. <br />CONDUIT <br />SIZE WIDTH LENGTH DEPTH WIDTH INCREASE PER <br />ADDITIONAL CONDUIT <br />1" <br />2" <br />3" <br />4" <br />4" <br />8" <br />12" <br />15" <br />16" <br />36" <br />48" <br />60" <br />3" <br />4" <br />5" <br />8" <br />2" <br />5" <br />6" <br />8" <br />ALL BRANCH CIRCUITS, FIRE ALARM CIRCUITS, LIGHTING CONTROL <br />CONDUCTORS, AND CONDUITS/SLEEVES FOR AV/TEL/DATA/SECURITY AND <br />OTHER TECHNOLOGY SYSTEMS INFRASTRUCTURE SHALL BE ROUTED IN EMT <br />WITHIN SUCH AREA. OPEN CONDUCTORS AND MC CABLES SHALL NOT BE <br />UTILIZED IN THESE AREAS. <br />ALL CONDUITS/SLEEVES IN THESE SPACES SHALL BE EXTENDED INTO/ABOVE <br />CONCEALED ACCESSIBLE CEILING SPACES - TERMINATING A MINIMUM OF 5FT <br />HORIZONTALLY FROM THE OPEN OR EXPOSED CEILING CONDITION. <br />REVIEW PROPOSED ROUTING OF CONDUIT WITH ARCHITECT PRIOR TO <br />INSTALLATION. VISUALLY OBJECTIONABLE BRANCH CIRCUITS/CONDUIT SHALL BE <br />REROUTED AT THE REQUEST OF THE ARCHITECT AT NO ADDITIONAL COST. <br />IN AREAS WITH "OPEN" CEILINGS, "EXPOSED" CEILINGS, OR OPEN GRID (NO TILES <br />INSERTED) OR GRID CEILINGS WITH MORE THAN 25% OPEN OR TRANSPARENT <br />AREA ALLOWING BEAMS AND OTHER STRUCTURAL ELEMENTS, HVAC DUCT WORK, <br />ETC., TO BE VIEWABLE BY THE OCCUPANTS. THE ELECTRICAL CONTRACTOR SHALL <br />TAKE EXTRA CARE WITH INSTALLATION OF CONDUIT TO INCLUDE MEETING THE <br />FOLLOWING ADDITIONAL INSTALLATION CRITERIA: <br />- <br />CONDUIT FOR ALL BRANCH CIRCUITS, FIRE ALARM CIRCUITS, LIGHTING <br />CONTROL CONDUCTORS AV/TEL/DATA INFRASTRUCTURE SHALL BE ROUTED <br />NEATLY, TIGHT TO THE DECK ABOVE AND PARALLEL TO STRUCTURAL <br />BEAMS/FRAMING, DUCT WORK AND PLUMBING RELATED PIPING. <br />- <br />- <br />OPEN CEILING COORDINATION NOTES: <br />FOR OTHER CONDUIT SIZES REFER TO ANSI/TIA-569-C TABLE 12. - LATEST <br />PUBLISHED EDITION. <br />PROVIDE 6" THICK CONCRETE PAD EXTENDING 3" BELOW GRADE, 3" ABOVE <br />GRADE AND 6" BEYOND ALL FOUR (4) SIDES OF EQUIPMENT. <br />PROVIDE 3/4" C.O.(S) TO RESPECTIVE CONTROL DEVICE(S) FOR CONTROL <br />WIRING. REFER TO THE EQUIPMENT CONTROL WIRING DIAGRAMS FOR <br />ADDITIONAL INFORMATION. <br />REFER TO MOTORIZED EQUIPMENT SCHEDULE FOR MOTOR FEEDER/ BRANCH <br />CIRCUIT INFORMATION. <br />2 <br />3 <br />ELECTRICAL CONTRACTOR SHALL PROVIDE LOCAL REMOTE DISCONNECTING <br />MEANS FOR ALL ELECTRIC HEATING EQUIPMENT IF REQUIRED BY THE LOCAL <br />ELECTRICAL CODE. <br />4. <br />6. <br />5. <br />ALL ROOF MOUNTED EQUIPMENT SHALL BE NEMA 3R RATED. <br />ELECTRICAL CONTRACTOR SHALL COORDINATE THE ROUTING OF <br />CONDUIT/WIRING TO ROOF-MOUNTED EQUIPMENT WITH EQUIPMENT INSTALLER <br />PRIOR TO ROUGH-IN. WHERE ROOF-MOUNTED EQUIPMENT IS MANUFACTURED <br />TO BE FED FROM WITHIN MECHANICAL CURB ASSEMBLY - SEPARATE ROOF <br />PENETRATIONS FOR WIRING CONNECTIONS SHALL NOT BE PERMITTED. ALL <br />WIRING SHALL BE BELOW THE ROOF IN AN ACCESSIBLE CEILING SPACE <br />LOCATION. <br />HVAC GENERAL NOTES: <br />3. <br />2. <br />1. <br />ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF ALL <br />CONNECTION POINTS WITH THE EQUIPMENT INSTALLER PRIOR TO ROUGH-IN. <br />ALL TEMPERATURE CONTROL AND INTERLOCK CONDUIT AND WIRING SHALL BE <br />BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. SEE <br />MECHANICAL/PLUMBING DRAWINGS FOR ALL INFORMATION. <br />ELECTRICAL CONTRACTOR SHALL REFER TO MECHANICAL/PLUMBING AND <br />ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND CHARACTERISTICS OF <br />ALL EQUIPMENT LISTED IN SCHEDULE. ANY MODIFICATIONS AND/OR ADDITIONAL <br />WORK NECESSARY SHALL BE INCLUDED IN THE BASE BID. <br />UNLESS SPECIFICALLY SHOWN AS (E), (R), (ER), (D), EXISTING OR NON-BOLD, <br />ALL ELECTRICAL DEVICES SHOWN ARE NEW. <br />7. <br />ALL TERMINATIONS AND ENCLOSURES SHALL BE RATED FOR USE WITH 75 DEGREE C <br />CONDUCTORS. <br />7. <br />COMPLETE INSTALLATION SHALL CONFORM TO THE REQUIREMENTS OF NEC (OR CEC WHERE <br />ADOPTED) ARTICLES 430 AND 440. <br />8. <br />STARTERS SHALL BE FULL VOLTAGE, REDUCED VOLTAGE OR COMBINATION DISCONNECT AND <br />STARTER, WITH CONTROL VOLTAGE AS REQUIRED, AS INDICATED ON THE DOCUMENTS RELATED <br />TO THE EQUIPMENT, SUCH AS SHOP DRAWINGS, CONSTRUCTION DOCUMENTS, ETC. STARTERS <br />SHALL INCLUDE MOTOR OVERLOAD PROTECTION, PHASE LOSS AND PHASE UNBALANCE <br />PROTECTION AS REQUIRED. <br />DISCONNECT SWITCHES SHALL BE HEAVY DUTY TYPE, EXTERNALLY OPERATED, QUICK MAKE <br />QUICK BREAK AND SHALL BE FUSIBLE OR NON FUSIBLE AS INDICATED. A MAXIMUM VOLTAGE, <br />CURRENT AND HORSEPOWER SHALL BE CLEARLY MARKED ON SWITCH ENCLOSURE. SWITCHES <br />HAVING DUAL RATINGS (HIGHER RATINGS WHEN USED WITH DUAL ELEMENT FUSES) SHALL HAVE <br />RATINGS INDICATED ON METAL PLATES RIVETED OR OTHERWISE PERMANENTLY ATTACHED TO <br />THE ENCLOSURE. WHEN INDICATED, TOGGLE SWITCHES SHALL BE MOTOR RATED FOR THE <br />APPLICATION. <br />ELECTRICAL CONTRACTOR SHALL PROVIDE FUSES SIZED PER THE EQUIPMENT NAMEPLATE <br />INFORMATION. <br />ELECTRICAL CONTRACTOR SHALL CHECK THE ROTATION OF ALL THREE PHASE MOTORS AND <br />CORRECT THE ROTATION IF REVERSED. <br />ELECTRICAL CONTRACTOR SHALL REFER TO ALL DOCUMENTS RELATED TO THE EQUIPMENT (I.E. <br />SHOP DRAWINGS, CONSTRUCTION DOCUMENTS, ETC.) IN REGARDS TO ELECTRICAL <br />CHARACTERISTICS OF ALL EQUIPMENT LISTED IN THE SCHEDULE. ANY MODIFICATION AND/OR <br />ADDITIONAL WORK NECESSARY SHALL BE INCLUDED IN THE <br />BASE BID. <br />ALL BRANCH CIRCUIT DATA IS BASED UPON METALLIC CONDUITS. IF THE CONTRACTOR ELECTS <br />TO USE NONMETALLIC CONDUITS, AN EQUIPMENT GROUNDING CONDUCTOR SHALL BE INSTALLED <br />PER NEC, OR CEC WHERE ADOPTED, TABLE 250.122 AND THE CONDUIT SIZE SHALL BE INCREASED <br />ACCORDINGLY. <br />MOTORIZED EQUIPMENT SCHEDULE SPECIFIC NOTES: <br />5. <br />6. <br />4. <br />3. <br />2. <br />1. <br />MOTORIZED EQUIPMENT SCHEDULE <br />VOLTS <br />CEILING FAN <br />-208 <br />DESCRIPTIONITEM <br />MCA MOCPFLAHPPH. <br />3 --1.6 15 30AS/3P <br />- <br />MOTOR <br />3/4"C.,4#12 <br />DP1-1,3,5 A <br />ROUTE THROUGH LINE VOLTAGE CONTROL. SEE MECHANICAL AND/OR PLUMBING PLANS FOR <br />ADDITIONAL REQUIREMENTS. <br />FUSED AS RECOMMENDED BY MANUFACTURER.A. <br />B. <br />HVLS <br />1 <br />9.CONTRACTOR TO COORDINATE WITH ALL OTHER PROJECT TRADES AND WITH OWNER/ TENANT <br />FOR TO OBTAIN RESPECTIVE EQUIPMENT SCCR AND PROVIDE APPROPRIATE PROTECTIVE <br />DEVICES TO LIMIT AVAILABLE FAULT CURRENT TO LESS THAN THE EQUIPMENT NAMEPLATE SCCR <br />PER NEC (OR CEC WHERE ADOPTED) 110.10. SEE POWER SYSTEM STUDY SPECIFICATIONS FOR <br />ADDITIONAL REQUIREMENTS. <br />10.UNLESS OTHERWISE NOTED, MOCP VALUES FOR VFD-EQUIPPED DEVICE ARE SIZED PER NEC (OR <br />CEC WHERE ADOPTED) 430.130(A).1. CONTRACTOR SHALL COORDINATE WITH ALL OTHER <br />PROJECT TRADES AND WITH OWNER/ TENANT (IF PROVIDING EQUIPMENT ON PROJECT) TO <br />OBTAIN NAMEPLATE VFD-EQUIPPED DEVICE MOCP VALUE FROM MANUFACTURER INSTALLATION <br />INSTRUCTIONS AND PROVIDE APPROPRIATE PROTECTIVE DEVICES TO COMPLY WITH NEC (OR <br />CEC WHERE ADOPTED) 430.130(A).2. <br />EQUIPMENT RATING <br />VFD <br />FLA <br />- <br />ELECTRIC RADIANT <br />HEATER 208 1 --21.6 30 60AS/3P <br />-1"C.,2#8 <br />DP1-2,4 AERC <br />1 <br />- <br />--ERC <br />2 <br />- <br />--ERC <br />3 <br />- <br />--ERC <br />4 <br />- <br />SPECIFIC <br />NOTES <br />CIRCUIT DATA <br />CONDUIT - WIRE <br />DISC. SW. SIZE <br />STARTER SIZE <br />MOTORIZED EQUIPMENT SCHEDULE <br />GENERAL NOTES: <br />ELECTRIC RADIANT <br />HEATER 208 1 21.6 30 60AS/3P <br />-1"C.,2#8 <br />DP1-6,8 A <br />ELECTRIC RADIANT <br />HEATER 208 1 21.6 30 60AS/3P <br />-1"C.,2#8 <br />DP1-10,12 A <br />ELECTRIC RADIANT <br />HEATER 208 1 21.6 30 60AS/3P <br />-1"C.,2#8 <br />DP1-14,16 A <br />21159.00 <br />1202 W Edinger <br />Ave10/3/2024